通过交互式滤波Tc-99m PYP SPECT图像改进TTR淀粉样变性的评估:「清洁血池」成像的作用
研究纳入176例转诊行TTR淀粉样变性显像的连续患者,采用三探头数字相机行SPECT并铅荧光衰减校正,比较Butterworth滤波与交互式逆高斯滤波区分心肌摄取与血池的能力。以「清洁血池」为诊断标准,逆高斯滤波使视觉评分1+的可疑病例中93%变为可诊断,HCL 1-1.5的可疑病例中96%变为可诊断,均优于Butterworth滤波。
要点
- 视觉评分1+的可疑病例中,逆高斯滤波93%可诊断,Butterworth仅29%。
- HCL 1-1.5的可疑病例中,逆高斯滤波96%可诊断,Butterworth仅35%。
- 逆高斯滤波使「清洁血池」识别率增加三倍以上,大幅减少可疑扫描。
核心结论
- 使用优化重建的逆高斯交互滤波可在绝大多数PYP扫描可疑的患者中识别出清洁血池,并大幅减少可疑扫描数量。
研究设计与样本
- 研究纳入176例转诊行TTR淀粉样变性显像的连续患者,全部行平面显像,其中101例使用大视野相机可行HCL测量。
- SPECT采用三探头数字相机并铅荧光衰减校正,1例因技术原因被排除。
- 开发软件在重建时进行交互式滤波,并将图像叠加于衰减mu图上辅助定位心肌/纵隔摄取。
- 采用常规Butterworth滤波与交互式逆高斯滤波区分心肌摄取与残余血池。
- 「清洁血池」定义为可辨认的血池且周围心肌无活性;扫描显示清洁血池、阳性摄取或无可辨认纵隔摄取即判定为可诊断。
主要发现
- 175例中76例(43%)视觉摄取为可疑(1+)。
- 视觉可疑病例中,Butterworth滤波22例(29%)可诊断,逆高斯滤波71例(93%)可诊断(p < .0001)。
- 101例中71例(70%)HCL为可疑(1-1.5)。
- HCL可疑病例中,Butterworth滤波25例(35%)可诊断,逆高斯滤波68例(96%)可诊断(p < .0001)。
- 上述差异由逆高斯滤波识别清洁血池的增加超过三倍所驱动。
关键数值与推荐
- 视觉评分(VS)采用0-3+分级,HCL为心脏与对侧肺比值。
- 视觉1+和HCL 1-1.5被定义为可疑。
- 清洁血池定义为可辨认血池且周围心肌无活性。
- 扫描显示清洁血池、阳性摄取或无可辨认纵隔摄取即判定为可诊断。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Myocardial imaging with bone agents such as Tc-99 m PYP and HMDP has assumed a central role in the evaluation of patients with suspected transthyretin (TTR) amyloidosis. Visual scoring (VS) (0-3 +) and the heart to contralateral lung ratio (HCL) classify many patients as equivocal when mediastinal uptake is apparent but cannot be further differentiated into myocardial uptake versus blood pool. SPECT imaging has been recommended but current reconstruction protocols frequently produce amorphous mediastinal activity that also fails to discriminate between myocardial activity and blood pool. We hypothesized that interactive filtering interactively using a deconvolving filter would improve this. METHODS: We identified 176 sequential patients referred for TTR amyloid imaging. All patients had planar imaging, 101 had planar imaging with a large field of view camera that allowed HCL measurements. SPECT imaging was performed on a 3-headed digital camera with lead fluorescence attenuation correction. One study was excluded for technical reasons. We created software to allow interactive filtering while reconstructing the images then overlay them on attenuation mu maps to assist localization of myocardial/mediastinal uptake. Conventional Butterworth and an interactive inverse Gaussian filters were employed to differentiate myocardial uptake from residual blood pool. We defined "clean blood pool" (CBP) as recognizable blood pool with no activity in the surrounding myocardium. A scan was determined diagnostic if it showed CBP, positive uptake or no identifiable mediastinal uptake. RESULTS: 76/175 (43%) were equivocal (1 +) by visual uptake. Of these 22 (29%) were diagnostic by Butterworth but 71 (93%) were by inverse gaussian (p < .0001). 71/101 (70%) were equivocal by HCL (1-1.5). Of these, 25 (35%) were diagnostic by Butterworth but 68 (96%) were diagnostic by inverse gaussian (p < .0001). This was driven by a greater than threefold increase in the identification of CBP by inverse gaussian filtering. CONCLUSION: CBP can be identified in the vast majority of patients with equivocal PYP scans using optimized reconstruction and can greatly reduce the number of equivocal scans.
引用
- Hansen CL. Improving evaluation for TTR amyloidosis by interactive filtering of Tc-99 m PYP SPECT images. The role for "clean blood pool" imaging. J Nucl Cardiol. 2023. PMID: 37173549. doi:10.1007/s12350-023-03291-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。