观察者研究:三维高斯后重建滤波与深度学习去噪对减少计数心脏单光子发射计算机断层扫描心肌灌注成像图像质量的影响

Observer studies of image quality of denoising reduced-count cardiac single photon emission computed tomography myocardial perfusion imaging by three-dimensional Gaussian post-reconstruction filtering and deep learning.
PubMed 文献 · J Nucl Cardiol · 2023-05-23

研究使用156例常规判读患者的SPECT投影数据,其中一半被修改为包含已知位置和存在的混合灌注缺损,比较三维高斯后重建滤波与深度学习去噪在不同计数水平下对灌注缺损检测准确性的影响。结果显示,在计数降至全计数的25%或12.5%时,深度学习去噪的AUC较高斯去噪无统计学显著提高;作者结论为在本研究所用剂量水平和DL网络下,未发现DL去噪在AUC上优于优化的三维后重建高斯滤波的迹象。

要点

  • 在计数降至全计数25%或12.5%时,DL去噪与高斯去噪的AUC无统计学显著差异。
  • 仅用RC加高斯滤波的全计数OSEM平均AUC低于联合AC和SC的策略(6.25%全计数除外)。
  • 本研究未发现DL去噪在AUC上优于优化三维后重建高斯滤波的迹象。

核心结论

  • 在本研究所用剂量水平和DL网络下,未发现DL去噪在AUC上优于优化三维后重建高斯滤波的迹象。

研究设计与样本

  • 使用156例常规判读患者的SPECT投影数据进行观察者研究,其中一半被修改为包含已知存在和位置的混合灌注缺损。
  • 采用OSEM重建,可选联合AC和SC以及RC,计数水平从全计数(100%)变化至全计数的6.25%。
  • 去噪策略此前已使用TPD针对缺损检测进行优化,由4名医学物理学家(PhD)和6名医师(MD)观察者通过图形用户界面评分。
  • 观察者评分使用LABMRMC多阅片者多病例ROC软件分析,计算并统计学比较AUC。

主要发现

  • 在相同计数水平下,当计数降至全计数的25%或12.5%时,DL去噪较高斯去噪的AUC无统计学显著增加。
  • 仅用RC加高斯滤波的全计数OSEM平均AUC低于联合AC和SC的策略,但计数降至全计数6.25%时除外。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim of this research was to asses perfusion-defect detection-accuracy by human observers as a function of reduced-counts for 3D Gaussian post-reconstruction filtering vs deep learning (DL) denoising to determine if there was improved performance with DL. METHODS: SPECT projection data of 156 normally interpreted patients were used for these studies. Half were altered to include hybrid perfusion defects with defect presence and location known. Ordered-subset expectation-maximization (OSEM) reconstruction was employed with the optional correction of attenuation (AC) and scatter (SC) in addition to distance-dependent resolution (RC). Count levels varied from full-counts (100%) to 6.25% of full-counts. The denoising strategies were previously optimized for defect detection using total perfusion deficit (TPD). Four medical physicist (PhD) and six physician (MD) observers rated the slices using a graphical user interface. Observer ratings were analyzed using the LABMRMC multi-reader, multi-case receiver-operating-characteristic (ROC) software to calculate and compare statistically the area-under-the-ROC-curves (AUCs). RESULTS: For the same count-level no statistically significant increase in AUCs for DL over Gaussian denoising was determined when counts were reduced to either the 25% or 12.5% of full-counts. The average AUC for full-count OSEM with solely RC and Gaussian filtering was lower than for the strategies with AC and SC, except for a reduction to 6.25% of full-counts, thus verifying the utility of employing AC and SC with RC. CONCLUSION: We did not find any indication that at the dose levels investigated and with the DL network employed, that DL denoising was superior in AUC to optimized 3D post-reconstruction Gaussian filtering.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Pretorius PH, Liu J, Kalluri KS, et al. Observer studies of image quality of denoising reduced-count cardiac single photon emission computed tomography myocardial perfusion imaging by three-dimensional Gaussian post-reconstruction filtering and deep learning. J Nucl Cardiol. 2023. PMID: 37221409. doi:10.1007/s12350-023-03295-3