PubMed 文献 · J Nucl Cardiol · 2023-05-04

本研究通过确定性建模设计数字体模,模拟左移、右移和右位心三种心脏位置异常,比较标准采集弧度与调整后采集弧度下左心室间隔壁和侧壁的放射性分布。结果显示调整采集弧度后左心室壁的放射性分布更接近心脏正常位置体模的表现。

要点

  • 标准采集弧度下左心室间隔壁放射性明显高于侧壁,调整弧度后两壁放射性趋于一致。
  • 右位心体模中,360°弧度下基底段间隔壁和侧壁的衰减程度高于调整后180°弧度。
  • 调整采集弧度可使左心室壁放射性分布更接近心脏正常位置体模的表现。

核心结论

  • 调整采集弧度对左心室壁放射性分布产生可察觉的变化,且更符合心脏正常位置体模的分布。

研究设计与样本

  • 本研究采用确定性建模方法设计数字体模,模拟心脏左移、右移和右位心三种位置异常。
  • 分别模拟标准采集弧度(从右前斜位到左后斜位)和调整后采集弧度的扫描过程并进行比较。
  • 调整弧度分别为:左移从前方到后方、右移从右侧到左侧、右位心从左前斜位到右后斜位。
  • 所得投影采用滤波反投影算法重建,前向投影获得正弦图时通过简化透射图与发射图叠加模拟辐射衰减。
  • 所有计算在MATLAB软件包中完成。

主要发现

  • 在横断面图像上,间隔壁和侧壁的衰减均从更靠近探头的心尖向基底部逐渐加重,方式相似。
  • 标准采集弧度的断层图像中间隔壁的放射性明显高于侧壁;调整弧度后两壁放射性看起来相等,并呈从心尖到基底部的逐渐衰减,与心脏正常位置体模中的表现相似。
  • 右移体模以标准弧度扫描时间隔壁放射性高于侧壁,调整弧度后两壁放射性相等。
  • 右位心体模中,基底段间隔壁和侧壁的衰减程度在360°弧度下高于调整后的180°弧度。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To simulate cardiac malpositions, leftward and rightward shift and dextrocardia, and also to compare distribution of activity of septal and lateral walls of left ventricle acquired in standard acquisition arc and after relevant adjustment. METHODS: In this study, digital phantoms with cardiac malpositions are designed and procedure of acquisition of scan in standard arc (from right anterior oblique to left posterior oblique) and adjusted acquisition arc is simulated. The three situations of malposition including leftward and rightward shift and dextrocardia are considered. For all types, acquisition is conducted in standard and then adjusted arcs (from anterior to posterior and also from right to left for leftward and rightward shifts, respectively, and for dextrocardia, from left anterior oblique to right posterior oblique). All obtained projections are reconstructed using the algorithm of filtered back projection. During forward projection to obtain sinograms, radiation attenuation is also modeled by incorporation of a simplified transmission map to emission map. The resulting tomographic slices of the LV (septum, apex, and lateral wall) are presented visually and are compared by plotting intensity profiles of the walls. Finally, normalized error images are also computed. All the computations are performed in MATLAB software package. RESULTS: In transverse slice, septum and lateral wall are attenuated progressively from apex, which is closer to the camera, to the base in similar fashion. In tomographic slices of standard acquisition arc, the septum shows remarkably higher activity compared to lateral wall. However, after adjustment, both seems equally intense and progressively being attenuated from apex to base, similar to that found in phantom with normally positioned heart. Likewise, for the phantom with rightward shift, when the scanning was done in standard arc, the septum is more intense than the lateral wall. And similarly, adjustment of the arc renders both walls equally intense. In dextrocardia, level of attenuation of basal parts of septum and lateral wall is higher in 360° arc compared to adjusted 180° arc. CONCLUSION: Adjustment of acquisition arc exerts perceptible changes in distribution of activity over LV walls which are more compatible with normally positioned heart.