文献速递神经核医学

三个大型数据库中视觉正常123I-FP-CIT的半定量分析显示对照组与患者之间无差异

Semi-quantitative analysis of visually normal 123I-FP-CIT across three large databases revealed no difference between control and patients.
PubMed 文献 · EJNMMI Res · 2023-04-28

研究比较三组视觉正常123I-FP-CIT SPECT扫描的特定结合比值(SBR):疑似帕金森综合征无诊断随访者(ScanOnlyDB,n=764)、5年随访无多巴胺能退行性病变者(NoDG5YearsDB,n=237)及健康志愿者(HvDB,n=118)。经重建后协调化处理并以一般线性模型分析,结果显示各数据库间离散参数、R²及SBR变异系数无差异,SBR随年龄显著下降,ScanOnlyDB的模型估计与SiemensDB及ENC-DAT无显著差异(年龄-性别交互作用除外)。结论认为视觉正常扫描的SBR分布与现有参考数据库无差异,可由专家核医学医师据此建立参考数据库。

要点

  • 视觉正常123I-FP-CIT扫描的SBR分布与现有参考数据库无差异。
  • 所有感兴趣区和所有数据库中SBR均随年龄显著下降,如纹状体每十年下降-4.94%至-5.69%。
  • ScanOnlyDB与NoDG5YearsDB中SBR与性别存在显著协方差,年龄-性别交互作用仅ScanOnlyDB显著。

核心结论

  • 视觉正常扫描的SBR值分布与现有参考数据库无差异,使专家核医学医师能够以此方法创建参考数据库。
  • 研究还显示了与样本量相关的、罕见报道的年龄-性别交互作用。
  • 所提出的重建后协调化方法可促进半定量分析的使用。

研究设计与样本

  • 研究分析三组视觉正常123I-FP-CIT SPECT扫描的SBR值:疑似帕金森综合征且无诊断随访者(ScanOnlyDB,n=764,NM/CT 670 CZT,GE Healthcare)。
  • 5年随访后无退行性多巴胺能病变者(NoDG5YearsDB,n=237,Symbia T2,Siemens Medical Solutions)。
  • 健康志愿者(HvDB,n=118,商业GE数据库)。
  • 以尾状核、壳核和纹状体SBR为因变量、年龄和性别为自变量构建一般线性模型(GLM)。
  • 数据经重建后协调化处理后,将数据库两两合并(ScanOnlyDB与NoDG5YearsDB、ScanOnlyDB与HvDB)再进行GLM分析,并将ScanOnlyDB的GLM估计与Siemens商业数据库(SiemensDB)及ENC-DAT已发表数据比较。

主要发现

  • 各数据库间的离散参数、R²和SBR变异系数无差异。
  • 所有感兴趣区和所有数据库中SBR均随年龄显著下降,纹状体每十年下降:ScanOnlyDB为-4.94%,NoDG5YearsDB为-4.65%,HvDB为-5.69%。
  • ScanOnlyDB中SBR与性别存在显著协方差(P < 10^-5),NoDG5YearsDB中亦显著(P < 10^-2)。
  • 年龄-性别交互作用仅在ScanOnlyDB中显著(P < 10^-2),ScanOnlyDB与NoDG5YearsDB合并后P值降至10^-6。
  • ScanOnlyDB的GLM估计与SiemensDB或ENC-DAT无显著差异,年龄-性别交互作用除外。

临床怎么用

  • 原文结论认为视觉正常扫描的SBR分布与现有参考数据库无差异,使专家核医学医师能够以此方法创建参考数据库。
  • 原文结论认为所提出的重建后协调化方法可促进半定量分析的使用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To show the equivalence between the specific binding ratios (SBR) of visually normal 123I-FP-CIT SPECT scans from patients to those from healthy volunteers (Hv) or patients without dopaminergic degeneration to allow their use as a reference database. METHODS: The SBR values of visually normal SPECT scans from 3 groups were studied: (1) suspected Parkinsonism and no diagnostic follow-up (ScanOnlyDB: n = 764, NM/CT 670 CZT, GE Healthcare), (2) no degenerative dopaminergic pathology after a 5-year follow-up (NoDG5YearsDB: n = 237, Symbia T2, Siemens Medical Solutions), and 3) Hv (HvDB: n = 118, commercial GE database). A general linear model (GLM) was constructed with caudate, putamen, and striatum SBR as the dependent variables, and age and gender as the independent variables. Following post-reconstruction harmonization of the data, DB were combined in pairs, ScanOnlyDB&NoDG5yearsDG and ScanOnlyDB&HvDB before performing GLM analysis. Additionally, ScanOnlyDB GLM estimates were compared to those published from Siemens commercial DB (SiemensDB) and ENC-DAT. RESULTS: The dispersion parameters, R2 and the SBR coefficients of variation, did not differ between databases. For all volumes of interest and all databases, SBR decreased significantly with age (e.g., decrease per decade for the striatum: - 4.94% for ScanOnlyDB, - 4.65% for NoDG5YearsDB, - 5.69% for HvDB). There was a significant covariance between SBR and gender for ScanOnlyDB (P < 10-5) and NoDG5YearsDB (P < 10-2). The age-gender interaction was significant only for ScanOnlyDB (P < 10-2), and the p-value decreased to 10-6 after combining ScanOnlyDB with NoDG5YearsDB. ScanOnlyDB GLM estimates were not significantly different from those from SiemensDB or ENC-DAT except for age-gender interaction. CONCLUSION: SBR values distribution from visually normal scans were not different from the existing reference database, enabling this method to create a reference database by expert nuclear physicians. In addition, it showed a rarely described age-gender interaction related to its size. The proposed post-reconstruction harmonization method can also facilitate the use of semi-quantitative analysis.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Flaus A, Philippe R, Thobois S, et al. Semi-quantitative analysis of visually normal 123I-FP-CIT across three large databases revealed no difference between control and patients. EJNMMI Res. 2023. PMID: 37117951. doi:10.1186/s13550-023-00983-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。