比较锝-99m焦磷酸盐闪烁显像胸部与心脏聚焦重建对转甲状腺素蛋白心脏淀粉样变性诊断的质量保证研究

Comparison of cardio-focal and chest reconstruction of technetium-99m pyrophosphate scintigraphy for diagnosis of transthyretin cardiac amyloidosis: a quality assurance study.
PubMed 文献 · J Nucl Cardiol · 2023-04-03

该质量保证研究对102例白人患者的锝-99m焦磷酸盐(PYP)SPECT/CT数据进行盲法评估,读者1阅胸部SPECT、读者2阅心脏聚焦SPECT。两位读者对视觉评分≥2的一致性良好(k=0.88,P<.001),对断层心肌摄取一致性极好(98%,P<.001);心脏聚焦重建仅1例假阴性,但22%阳性患者为非弥漫性摄取,作者认为应强烈考虑胸部重建。

要点

  • 胸部与心脏聚焦PYP SPECT重建在经验丰富读者间诊断性能相当。
  • 视觉评分≥2的读者间一致性良好(k=0.88,P<.001)。
  • 22%的PYP SPECT阳性患者为非弥漫性心肌摄取。

核心结论

  • 经验丰富读者判读时,胸部与心脏聚焦PYP SPECT重建的诊断性能相当。
  • 相当比例(22%)的PYP SPECT阳性患者为非弥漫性PYP分布。
  • 鉴于单独心脏聚焦重建可能对非弥漫性心肌摄取误分类,应强烈考虑胸部重建PYP闪烁显像。

研究设计与样本

  • 质量保证研究,盲法评估102例白人患者(平均年龄76±11岁,67%男性)的PYP SPECT/CT数据,由两位读者分别判读。
  • 读者1判读平面及胸部PYP SPECT,读者2判读平面及心脏聚焦PYP SPECT;人口学、临床及其他检查数据来自电子病历。

主要发现

  • 基于胸部PYP SPECT心肌摄取,41例患者(40%)判定为阳性。
  • 上述阳性患者中,98%在平面显像上Perugini评分≥2。
  • 两位读者对视觉评分≥2的一致性良好(k=0.88,P<.001),对断层心肌摄取的一致性极好(98%,P<.001)。
  • 心脏聚焦SPECT重建仅将1例研究判为假阴性。
  • PYP SPECT阳性患者中22%存在非弥漫性心肌摄取。

关键数值与推荐

  • 视觉评分≥2的读者间一致性k=0.88(P<.001)。
  • 断层心肌摄取的读者间一致性98%(P<.001)。

临床怎么用

  • 作者认为,鉴于单独心脏聚焦重建可能对非弥漫性心肌摄取误分类,应强烈考虑胸部重建PYP闪烁显像。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: SPECT improves diagnostic specificity of Technetium-99m pyrophosphate (PYP) scintigraphy. Diagnostic performance of PYP data, reconstructed as either chest or cardio-focal SPECT is not known. METHODS: In this quality assurance study, blinded evaluation of PYP SPECT/CT data from 102 Caucasian patients (mean age 76 ± 11 years, 67% men) was performed by two readers. Reader 1 reviewed planar and PYP chest SPECT, while reader 2 reviewed planar and cardio-focal PYP SPECT. Demographic, clinical, and other testing data were obtained from the electronic medical records. RESULTS: A total of 41 patients (40%) were considered positive based on myocardial uptake on chest PYP SPECT. Of these, 98% of the patients had a Perugini score ≥ 2 on planar imaging. There was good agreement between the two readers for visual score ≥ 2 (k = .88, P < .001) and excellent agreement for myocardial uptake on tomographic imaging (98%, P < .001). Only one study was categorized as false negative by cardio-focal SPECT reconstruction. Non-diffuse myocardial uptake was identified in 22% of those with a positive PYP SPECT. CONCLUSION: When read by experienced readers, chest and cardio-focal reconstruction of PYP SPECT have comparable diagnostic performance. A substantial proportion of patients with a positive PYP SPECT have a non-diffuse distribution of PYP. Given the possibility of misclassification of non-diffuse myocardial uptake on cardio-focal reconstruction alone, chest reconstruction of PYP scintigraphy should be strongly considered.