开发一种简易标准化评分系统用于18F-FDG PET-CT评估大血管炎及与动脉粥样硬化的鉴别
本研究基于60例患者的FDG PET/CT图像(30例活检证实的巨细胞动脉炎、30例严重动脉粥样硬化),由12名核医学医师按5项标准评估。经一致性和可靠性分析剔除3项标准,保留FDG摄取强度(与肝脏摄取比较)和动脉壁钙化构建6级评分系统;FDG摄取强度AUC为0.90(95%CI 0.87-0.92),联合钙化后AUC为0.91(95%CI 0.88-0.93),排除动脉假体病例后AUC升至0.93(95%CI 0.91-0.95)。
要点
- FDG摄取强度(与肝脏摄取比较)诊断大血管炎的AUC为0.90(95%CI 0.87-0.92)。
- 钙化程度单独判别能力差,AUC为0.62(95%CI 0.58-0.66)。
- 钙化与FDG摄取强度联合的6级评分AUC为0.91(95%CI 0.88-0.93)。
核心结论
- 标准化评估动脉壁FDG摄取强度,最好联合动脉钙化评估纳入评分方法,可准确但非完美地区分大血管炎与动脉粥样硬化。
研究设计与样本
- 评估60例患者的FDG PET/CT图像,其中30例为活检证实的巨细胞动脉炎(GCA,大血管炎最常见形式),30例为严重动脉粥样硬化。
- 由12名核医学医师使用5项标准评估图像:FDG摄取模式(强度、分布、环形)、钙化程度、钙化与FDG摄取的共定位。
- 通过一致性和可靠性测试的标准随后用受试者工作特征曲线(ROC)分析评估准确性,具有判别能力的标准组合成多组分评分系统。
- 观察者在详细检查图像前后分别报告初始和最终「格式塔」结论。
主要发现
- 一致性和可靠性分析剔除了5项标准中的3项,仅保留FDG摄取强度(与肝脏摄取比较)和动脉壁钙化用于评分系统。
- ROC分析显示FDG摄取强度的曲线下面积(AUC)为0.90(95%CI 0.87-0.92)。
- 钙化程度单独判别能力差,AUC为0.62(95%CI 0.58-0.66)。
- 将钙化存在与FDG摄取强度组合成6级评分系统后,AUC相似为0.91(95%CI 0.88-0.93)。
- 排除动脉假体病例后,AUC增至0.93(95%CI 0.91-0.95)。
关键数值与推荐
- FDG摄取强度(与肝脏摄取比较)AUC为0.90(95%CI 0.87-0.92)。
- 钙化程度AUC为0.62(95%CI 0.58-0.66)。
- 钙化联合FDG摄取强度的6级评分系统AUC为0.91(95%CI 0.88-0.93)。
- 排除动脉假体病例后6级评分系统AUC为0.93(95%CI 0.91-0.95)。
- 「格式塔」结论准确性初始89%(95%CI 86-91%),详细检查后93%(95%CI 91-95%)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: This study is to develop a structured approach to distinguishing large-artery vasculitis from atherosclerosis using 18-fluorodeoxyglucose positron emission tomography combined with low-dose computed tomography (FDG PET/CT). METHODS: FDG PET/CT images of 60 patients were evaluated, 30 having biopsy-proven giant cell arteritis (GCA; the most common form of large-artery vasculitis), and 30 with severe atherosclerosis. Images were evaluated by 12 nuclear medicine physicians using 5 criteria: FDG uptake pattern (intensity, distribution, circularity), the degree of calcification, and co-localization of calcifications with FDG-uptake. Criteria that passed agreement, and reliability tests were subsequently analysed for accuracy using receiver operator curve (ROC) analyses. Criteria that showed discriminative ability were then combined in a multi-component scoring system. Both initial and final 'gestalt' conclusion were also reported by observers before and after detailed examination of the images. RESULTS: Agreement and reliability analyses disqualified 3 of the 5 criteria, leaving only FDG uptake intensity compared to liver uptake and arterial wall calcification for potential use in a scoring system. ROC analysis showed an area under the curve (AUC) of 0.90 (95%CI 0.87-0.92) for FDG uptake intensity. Degree of calcification showed poor discriminative ability on its own (AUC of 0.62; 95%CI 0.58-0.66). When combining presence of calcification with FDG uptake intensity into a 6-tiered scoring system, the AUC remained similar at 0.91 (95%CI 0.88-0.93). After exclusion of cases with arterial prostheses, the AUC increased to 0.93 (95%CI 0.91-0.95). The accuracy of the 'gestalt' conclusion was initially 89% (95%CI 86-91%) and increased to 93% (95%CI 91-95%) after detailed image examination. CONCLUSION: Standardised assessment of arterial wall FDG uptake intensity, preferably combined with assessment of arterial calcifications into a scoring method, enables accurate, but not perfect, distinction between large artery vasculitis and atherosclerosis.
引用
- Bacour YAA, van Kanten MP, Smit F, et al. Development of a simple standardized scoring system for assessing large vessel vasculitis by 18F-FDG PET-CT and differentiation from atherosclerosis. Eur J Nucl Med Mol Imaging. 2023. PMID: 37115211. doi:10.1007/s00259-023-06220-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。