文献速递心脏核医学

冠状动脉CT血管成像影像特征联合CT血流储备分数、冠周脂肪衰减指数及放射组学预测心肌缺血

Coronary computed tomography angiography imaging features combined with computed tomography-fractional flow reserve, pericoronary fat attenuation index, and radiomics for the prediction of myocardial ischemia.
PubMed 文献 · J Nucl Cardiol · 2023-03-01

本研究纳入96例同时接受冠状动脉CT血管成像(CCTA)和单光子发射计算机断层心肌灌注显像(SPECT-MPI)的患者,构建传统模型、放射组学模型及多面模型预测心肌缺血(MIS)。结果显示,在传统模型中加入冠周脂肪衰减指数(pFAI)的预测效能优于加入CT血流储备分数(CT-FFR)(AUC 0.88 vs 0.80,P<0.05),多面模型预测效能最高(AUC 0.92)。

要点

  • 传统模型与放射组学模型预测效能相似(AUC 0.76 vs 0.74,P>0.05)。
  • 多面模型联合影像特征、CT-FFR、pFAI及放射组学,预测效能最高(AUC 0.92)。

核心结论

  • pFAI预测心肌缺血的效能优于CT-FFR。
  • 联合影像特征、CT-FFR、pFAI及放射组学的多面模型是预测心肌缺血的潜在诊断工具。

研究设计与样本

  • 基于支持向量机构建传统模型(病灶长度、最大狭窄直径百分比、最大狭窄面积百分比及CT值)、放射组学模型(放射组学特征)及多面模型(全部特征)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aimed to predict myocardial ischemia (MIS) by constructing models with imaging features, CT-fractional flow reserve (CT-FFR), pericoronary fat attenuation index (pFAI), and radiomics based on coronary computed tomography angiography (CCTA). METHODS AND RESULTS: This study included 96 patients who underwent CCTA and single photon emission computed tomography-myocardial perfusion imaging (SPECT-MPI). According to SPECT-MPI results, there were 72 vessels with MIS in corresponding supply area and 105 vessels with no-MIS. The conventional model [lesion length (LL), MDS (maximum stenosis diameter × 100% / reference vessel diameter), MAS (maximum stenosis area × 100% / reference vessel area) and CT value], radiomics model (radiomics features), and multi-faceted model (all features) were constructed using support vector machine. Conventional and radiomics models showed similar predictive efficacy [AUC: 0.76, CI 0.62-0.90 vs. 0.74, CI 0.61-0.88; p > 0.05]. Adding pFAI to the conventional model showed better predictive efficacy than adding CT-FFR (AUC: 0.88, CI 0.79-0.97 vs. 0.80, CI 0.68-0.92; p < 0.05). Compared with conventional and radiomics model, the multi-faceted model showed the highest predictive efficacy (AUC: 0.92, CI 0.82-0.98, p < 0.05). CONCLUSION: pFAI is more effective for predicting MIS than CT-FFR. A multi-faceted model combining imaging features, CT-FFR, pFAI, and radiomics is a potential diagnostic tool for MIS.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Hou J, Zheng G, Han L, et al. Coronary computed tomography angiography imaging features combined with computed tomography-fractional flow reserve, pericoronary fat attenuation index, and radiomics for the prediction of myocardial ischemia. J Nucl Cardiol. 2023. PMID: 36859595. doi:10.1007/s12350-023-03221-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。