文献速递心脏核医学

二维定量冠状动脉造影、三维定量冠状动脉造影与冠状动脉造影衍生血流储备分数在预测CZT-SPECT心肌灌注显像所评估心肌缺血中的比较

Comparison of 2D-QCA, 3D-QCA and coronary angiography derived FFR in predicting myocardial ischemia assessed by CZT-SPECT MPI.
PubMed 文献 · J Nucl Cardiol · 2023-03-16

本研究以CZT-SPECT心肌灌注显像为参考,评估冠状动脉造影衍生血流储备分数(angio-FFR)的诊断性能,并与二维及三维定量冠状动脉造影(2D-QCA、3D-QCA)测量的直径狭窄百分比(%DS)和面积狭窄百分比(%AS)比较。共分析131例患者282条冠状动脉,angio-FFR诊断心肌缺血的总体准确率为90.43%,灵敏度62.50%,特异度98.62%。angio-FFR的AUC与3D-QCA的%DS和%AS相似,但显著高于2D-QCA;在50-70%狭窄病变中,angio-FFR的AUC显著高于3D-QCA和2D-QCA。

要点

  • angio-FFR预测CZT-SPECT心肌缺血的总体准确率为90.43%,灵敏度62.50%,特异度98.62%。
  • angio-FFR的AUC(0.91)与3D-QCA的%DS(0.88)和%AS(0.88)相似,无显著差异。
  • 在50-70%狭窄病变中,angio-FFR的AUC显著高于3D-QCA和2D-QCA的%DS与%AS。

核心结论

  • angio-FFR预测CZT-SPECT评估的心肌缺血具有高准确率,与3D-QCA相似但显著高于2D-QCA。
  • 在中等程度病变(50-70%狭窄)中,angio-FFR在评估心肌缺血方面优于3D-QCA和2D-QCA。

研究设计与样本

  • 纳入在冠状动脉造影3个月内接受CZT-SPECT检查的患者,共分析131例患者的282条冠状动脉。
  • 使用计算流体力学计算angio-FFR,通过定量冠状动脉造影测量%DS和%AS。
  • 以血管供血区域 summed difference score ≥ 2 定义心肌缺血,angio-FFR ≤ 0.80 视为异常。

主要发现

  • angio-FFR检测CZT-SPECT心肌缺血的总体准确率为90.43%,灵敏度62.50%,特异度98.62%。
  • angio-FFR的AUC为0.91(95%CI 0.86-0.95),与3D-QCA的%DS(AUC=0.88,95%CI 0.84-0.93,p=0.326)和%AS(AUC=0.88,95%CI 0.84-0.93,p=0.241)相似。
  • angio-FFR的AUC显著高于2D-QCA的%DS(AUC=0.59,95%CI 0.51-0.67,p<0.001)和%AS(AUC=0.59,95%CI 0.51-0.67,p<0.001)。
  • 在50-70%狭窄血管中,angio-FFR的AUC(0.80)显著高于3D-QCA的%DS(0.47,p<0.001)和%AS(0.46,p<0.001)。
  • 在50-70%狭窄血管中,angio-FFR的AUC(0.80)显著高于2D-QCA的%DS(0.66,p=0.036)和%AS(0.66,p=0.034)。

关键数值与推荐

  • 心肌缺血定义为CZT-SPECT血管供血区域summed difference score ≥ 2。
  • angio-FFR ≤ 0.80 视为异常。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Angiography derived fractional flow reserve (angio-FFR) has been proposed. This study aimed to assess its diagnostic performance with cadmium-zinc-telluride single emission computed tomography (CZT-SPECT) as reference. METHODS AND RESULTS: Patients underwent CZT-SPECT within 3 months of coronary angiography were included. Angio-FFR computation was performed using computational fluid dynamics. Percent diameter (%DS) and area stenosis (%AS) were measured by quantitative coronary angiography. Myocardial ischemia was defined as a summed difference score ≥ 2 in a vascular territory. Angio-FFR ≤ 0.80 was considered abnormal. 282 coronary arteries in 131 patients were analyzed. Overall accuracy of angio-FFR to detect ischemia on CZT-SPECT was 90.43%, with a sensitivity of 62.50% and a specificity of 98.62%. The diagnostic performance (= area under ROC = AUC) of angio-FFR [AUC = 0.91, 95% confidence intervals (CI) 0.86-0.95] was similar as those of %DS (AUC = 0.88, 95% CI 0.84-0.93, p = 0.326) and %AS (AUC = 0.88, 95% CI 0.84-0.93 p = 0.241) by 3D-QCA, but significantly higher than those of %DS (AUC = 0.59, 95% CI 0.51-0.67, p < 0.001) and %AS (AUC = 0.59, 95% CI 0.51-0.67, p < 0.001) by 2D-QCA. However, in vessels with 50-70% stenoses, AUC of angio-FFR was significantly higher than those of %DS (0.80 vs. 0.47, p < 0.001) and %AS (0.80 vs. 0.46, p < 0.001) by 3D-QCA and %DS (0.80 vs. 0.66, p = 0.036) and %AS (0.80 vs. 0.66, p = 0.034) by 2D-QCA. CONCLUSION: Angio-FFR had a high accuracy in predicting myocardial ischemia assessed by CZT-SPECT, which is similar as 3D-QCA but significantly higher than 2D-QCA. While in intermediate lesions, angio-FFR is better than 3D-QCA and 2D-QCA in assessing myocardial ischemia.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Tang X, Dai N, Zhang B, et al. Comparison of 2D-QCA, 3D-QCA and coronary angiography derived FFR in predicting myocardial ischemia assessed by CZT-SPECT MPI. J Nucl Cardiol. 2023. PMID: 36929293. doi:10.1007/s12350-023-03240-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。