利用心肌灌注SPECT数据构建的虚拟平面图像进行肺心比分析:模型与临床研究

Lung-to-heart ratio analysis using virtual planar images obtained from myocardial perfusion SPECT data: A phantom and clinical studies.
PubMed 文献 · J Nucl Cardiol · 2023-03-14

研究开发了一种从心肌灌注SPECT数据构建虚拟平面图像(VPI)的新方法,并在Tl-201心肌模型和52例接受Tc-99m甲氧基异丁基异腈心肌灌注显像的患者中评估其肺心比(L/H比)分析效果。模型研究中VPI的放射性线性良好(r≥.99),VPI与常规平面图像的L/H比在模型中强相关(r≥.99),在临床应用中r=.929。结论认为VPI-based L/H比分析的准确性可与常规平面图像分析相媲美,VPI可作为临床获取平面图像的替代方法。

要点

  • VPI由SPECT所有冠状重建图像叠加构建,放射性线性良好(r≥.99)。
  • 模型研究中VPI与常规平面图像的L/H比强相关(r≥.99)。
  • 52例临床应用中VPI与常规平面图像的L/H比相关r=.929。

核心结论

  • 基于VPI的L/H比分析准确性可与常规平面图像分析相媲美。
  • VPI可作为临床环境中获取平面图像的替代方法。

研究设计与样本

  • 使用Tl-201构建不同肺放射性强度的 myocardial phantom,用Anger型伽马相机采集SPECT数据和常规平面图像,通过叠加所有冠状重建图像构建VPI。
  • 临床部分评估52例接受Tc-99m sestamibi心肌灌注显像患者的VPI临床效用。

主要发现

  • VPI的放射性线性满意,测量放射性量与图像计数之间的相关系数r≥.99。
  • 模型研究中VPI分析获得的L/H比与常规平面图像的L/H比强相关,相关系数r≥.99。
  • 临床应用中VPI与常规平面图像的L/H比相关系数r=.929。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUNDS: The lung-to-heart ratio (L/H ratio) in myocardial perfusion scintigraphy (MPS) is a useful marker that complements the sensitivity of ischemia detection. However, it requires planar imaging acquired following a separate protocol in addition to single-photon emission computed tomography (SPECT). We developed a novel method for constructing virtual planar image (VPI) from SPECT data. METHODS: Myocardial phantoms using Tl-201 were built with different amounts of radioactivity in the lungs. SPECT data and conventional planar images of these phantoms were collected with an Anger-type gamma camera. VPIs were constructed by adding all coronal images reconstructed from SPECT data. The clinical utility of VPIs obtained from 52 patients who underwent MPS with Tc-99m sestamibi was evaluated. RESULTS: The radioactivity linearity of VPIs was satisfactory, with a correlation coefficient of r ≥ .99 between the measured amounts of radioactivity and image counts. The L/H ratios obtained from VPI analysis were strongly correlated with those of conventional planar images with a correlation coefficient of r ≥ .99 in the phantom study and r = .929 in clinical application. CONCLUSION: The accuracy of VPI-based L/H ratio analysis was comparable to that of conventional planar image-based analysis. VPIs could be used as an alternative method of obtaining planar images in clinical settings.