半剂量5小时全身18F-FDG PET/CT扫描在高安动脉炎患者中的可行性与临床价值探索
本研究纳入9名健康志愿者行1、2.5、5小时三次全身PET/CT,55例高安动脉炎患者行2小时和5小时双时点全身PET/CT,示踪剂为1.85 MBq/kg 18F-FDG。健康志愿者2.5小时与5小时肝、血池、肌肉信噪比相似;活动期患者2小时与5小时病灶检出率相似,但5小时病灶/血池SUVmax比值更高;作者认为两时点联合可更好检测炎症病灶。
要点
- 健康志愿者2.5小时与5小时肝、血池、肌肉信噪比相似(0.117 vs 0.115,p=0.095)。
- 活动期高安动脉炎患者2小时与5小时病灶检出率相似(92.0% vs 94.2%,p=0.140)。
- 非活动期患者2小时与5小时阳性检出率相似(97.9% vs 98.6%,p=0.500)。
核心结论
- 2小时与5小时18F-FDG全身PET/CT扫描阳性检出率相似,但两者联合可更好检测高安动脉炎患者的炎症病灶。
研究设计与样本
- 纳入9名健康志愿者行1、2.5、5小时三次全身PET/CT扫描,55例高安动脉炎患者行2小时和5小时双时点全身PET/CT扫描,示踪剂剂量为1.85 MBq/kg 18F-FDG。
主要发现
- 健康志愿者2.5小时与5小时肝、血池和臀大肌信噪比相似(0.117 vs 0.115,p=0.095)。
- 39例活动期高安动脉炎患者共检出415个病灶,2小时与5小时平均病灶/血池SUVmax比值分别为3.67 vs 7.59(p<0.001)。
- 活动期患者2小时与5小时病灶检出率相似(92.0%(382/415) vs 94.2%(391/415),p=0.140)。
- 19例非活动期高安动脉炎患者共检出143个病灶,2小时与5小时病灶/血池SUVmax比值分别为2.99 vs 5.71(p<0.001)。
- 非活动期患者2小时与5小时阳性检出率相似(97.9%(140/143) vs 98.6%(141/143),p=0.500)。
关键数值与推荐
- 高安动脉炎病灶18F-FDG摄取采用三分法(I、II、III级)分级,II级和III级视为阳性病灶。
- 病灶/血池SUVmax比值(LBR)为病灶SUVmax除以血池SUVmax。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To explore the feasibility and clinical value of 5-h delayed 18F-fluorodeoxyglucose (18F-FDG) total-body (TB) positron emission tomography/computed tomography (PET/CT) in patients with Takayasu arteritis (TA). METHODS: This study included nine healthy volunteers who underwent 1-, 2.5-, and 5-h triple-time TB PET/CT scans and 55 patients with TA who underwent 2- and 5-h dual-time TB PET/CT scans with 1.85 MBq/kg 18F-FDG. The liver, blood pool, and gluteus maximus muscle signal-to-noise ratios (SNRs) were calculated by dividing the SUVmean by its standard deviation to evaluate imaging quality. TA lesions' 18F-FDG uptake was graded on a three-point scale (I, II, III), with grades II and III considered positive lesions. Lesion-to-blood maximum standardised uptake value (SUVmax) ratio (LBR) was calculated by dividing the lesion SUVmax by the blood pool SUVmax. RESULTS: The liver, blood pool, and muscle SNR of the healthy volunteers at 2.5- and 5-h were similar (0.117 and 0.115, respectively, p = 0.095). We detected 415 TA lesions in 39 patients with active TA. The average 2- and 5-h scan LBRs were 3.67 and 7.59, respectively (p < 0.001). Similar TA lesion detection rates were noted in the 2-h (92.0%; 382/415) and 5-h (94.2%; 391/415) scans (p = 0.140). We detected 143 TA lesions in 19 patients with inactive TA. The 2- and 5-h scan LBRs were 2.99 and 5.71, respectively (p < 0.001). Similar positive detection rates in inactive TA were noted in the 2-h (97.9%; 140/143) and 5-h (98.6%; 141/143) scans (p = 0.500). CONCLUSION: The 2- and 5-h 18F-FDG TB PET/CT scans had similar positive detection rates, but both combined could better detect inflammatory lesions in patients with TA.
引用
- Adili D, Cai D, Wu B, et al. An exploration of the feasibility and clinical value of half-dose 5-h total-body 18F-FDG PET/CT scan in patients with Takayasu arteritis. Eur J Nucl Med Mol Imaging. 2023. PMID: 36864361. doi:10.1007/s00259-023-06168-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。