深度学习通过解剖数据的弹性配准改善PET/CT衰减校正
本研究开发卷积神经网络对PET/CT图像行跨模态弹性配准,以非衰减校正PET/CT图像对为输入、输出相对位移向量场,用模拟图像间运动监督训练。在全身临床数据和心脏心肌灌注成像中,该技术可减少模拟运动及实际运动所致的衰减校正伪影,改善肝脏均匀性和心肌活性定量。
要点
- 单个配准网络可处理多种PET示踪剂,在PET/CT配准任务中表现先进。
- 配准CT至PET分布可减少实际运动受试者重建PET图像中的多种衰减校正伪影。
- 对有显著呼吸运动的受试者,肝脏均匀性得到改善,心肌活性定量伪影获纠正。
核心结论
- 本研究证明使用深度学习配准解剖图像以改善临床PET/CT重建中衰减校正是可行的。
- 该技术最显著地改善了肺/肝边界附近常见的呼吸伪影、粗大随意运动所致错配伪影以及心脏PET成像中的定量误差。
研究设计与样本
- 开发并训练卷积神经网络(CNN)用于配准任务,包含特征提取器和位移向量场(DVF)回归器两个模块。
- 网络以非衰减校正PET/CT图像对为输入,返回二者之间的相对DVF,采用模拟图像间运动以监督方式训练。
- 网络产生的3D运动场用于重采样CT图像体积,将其弹性变形以在空间上匹配相应PET分布。
- 在不同独立全身临床受试者数据集上评估算法性能:恢复无运动PET/CT对中人为施加的错配,以及改善实际受试者运动病例的重建伪影。
- 该技术在心脏心肌灌注成像(MPI)应用中改善PET衰减校正的效能也得到展示。
主要发现
- 单个配准网络能够处理多种PET示踪剂,在PET/CT配准任务中表现出先进性能,并能显著减少无运动临床数据中模拟运动的影响。
- 将CT配准至PET分布可减少实际运动受试者重建PET图像中的多种衰减校正伪影。
- 对有显著可观察呼吸运动的受试者,肝脏均匀性得到改善。
- 对MPI,该方法在纠正心肌活性定量伪影方面具有优势,并可能降低相关诊断错误率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: For PET/CT, the CT transmission data are used to correct the PET emission data for attenuation. However, subject motion between the consecutive scans can cause problems for the PET reconstruction. A method to match the CT to the PET would reduce resulting artifacts in the reconstructed images. PURPOSE: This work presents a deep learning technique for inter-modality, elastic registration of PET/CT images for improving PET attenuation correction (AC). The feasibility of the technique is demonstrated for two applications: general whole-body (WB) imaging and cardiac myocardial perfusion imaging (MPI), with a specific focus on respiratory and gross voluntary motion. MATERIALS AND METHODS: A convolutional neural network (CNN) was developed and trained for the registration task, comprising two distinct modules: a feature extractor and a displacement vector field (DVF) regressor. It took as input a non-attenuation-corrected PET/CT image pair and returned the relative DVF between them-it was trained in a supervised fashion using simulated inter-image motion. The 3D motion fields produced by the network were used to resample the CT image volumes, elastically warping them to spatially match the corresponding PET distributions. Performance of the algorithm was evaluated in different independent sets of WB clinical subject data: for recovering deliberate misregistrations imposed in motion-free PET/CT pairs and for improving reconstruction artifacts in cases with actual subject motion. The efficacy of this technique is also demonstrated for improving PET AC in cardiac MPI applications. RESULTS: A single registration network was found to be capable of handling a variety of PET tracers. It demonstrated state-of-the-art performance in the PET/CT registration task and was able to significantly reduce the effects of simulated motion imposed in motion-free, clinical data. Registering the CT to the PET distribution was also found to reduce various types of AC artifacts in the reconstructed PET images of subjects with actual motion. In particular, liver uniformity was improved in the subjects with significant observable respiratory motion. For MPI, the proposed approach yielded advantages for correcting artifacts in myocardial activity quantification and potentially for reducing the rate of the associated diagnostic errors. CONCLUSION: This study demonstrated the feasibility of using deep learning for registering the anatomical image to improve AC in clinical PET/CT reconstruction. Most notably, this improved common respiratory artifacts occurring near the lung/liver border, misalignment artifacts due to gross voluntary motion, and quantification errors in cardiac PET imaging.
引用
- Schaefferkoetter J, Shah V, Hayden C, et al. Deep learning for improving PET/CT attenuation correction by elastic registration of anatomical data. Eur J Nucl Med Mol Imaging. 2023. PMID: 36882577. doi:10.1007/s00259-023-06181-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。