平面定量与半定量Tc99m焦磷酸盐(PYP)显像诊断转甲状腺素蛋白(ATTR)心脏淀粉样变的诊断性能特征:SCAN-MP研究
在229例心衰且左室壁增厚、转甲状腺素蛋白心脏淀粉样变(ATTR-CA)验前概率低的少数族裔老年人中,以SPECT心肌PYP滞留为参考标准,评估3小时平面显像的半定量与定量参数的诊断性能。14例(6.1%)确诊ATTR-CA;H/CL阈值≥1.4时特异度99%、阳性预测值93%、灵敏度93%,而阈值≥1.3时灵敏度100%。作者认为平面判读有助于排除疾病但需谨慎,定量平面阈值可能不适用于低验前概率人群。
要点
- 229例中仅14例(6.1%)确诊ATTR-CA,总体验前概率低。
- 所有3级扫描均为ATTR-CA,11例2级扫描中仅4例(36%)为ATTR-CA。
- H/CL≥1.4时特异度99%、阳性预测值93%、灵敏度93%;H/CL≥1.3时灵敏度100%。
核心结论
- 在ATTR-CA验前概率低的患者中,平面判读有助于排除疾病但必须谨慎解读。
- H/CL比值阈值≥1.3导致了具有临床意义的误分类。
- 这些数据提示定量平面显像阈值可能不适用于正在评估ATTR-CA的低验前概率人群。
研究设计与样本
- 前瞻性招募的心衰且左室壁增厚的少数族裔老年人队列,共229例。
- 以SPECT心肌PYP滞留为参考标准,评估3小时PYP平面显像的半定量与定量(H/CL胸部比值)参数的诊断性能。
主要发现
- 229例中14例发现ATTR-CA(6.1%)。
- 77%的扫描未见PYP摄取(0级)。
- 所有3级扫描均为ATTR-CA。
- 11例2级扫描中仅4例(36%)为ATTR-CA。
关键数值与推荐
- H/CL阈值≥1.4时特异度99%、阳性预测值93%、灵敏度93%。
- H/CL阈值≥1.3时灵敏度100%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The optimal heart-to-contralateral chest (H/CL) ratio threshold for non-invasive diagnosis of transthyretin cardiac amyloidosis (ATTR-CA) using Tc99m pyrophosphate (PYP) imaging in a population with low pretest probability is not known. METHODS: Using myocardial PYP retention by SPECT as the reference standard, we evaluated the diagnostic performance of different semi-quantitative and quantitative (H/CL chest ratio) planar parameters obtained from 3-hour PYP imaging in a prospectively recruited cohort of minority older adults with heart failure and increased LV wall thickness. RESULTS: Of 229 patients, 14 were found to have ATTR-CA (6.1%). No PYP uptake (grade 0) was observed in 77% of scans, all grade 3 scans were ATTR-CA, and only 4 of 11 (36%) grade 2 scans were ATTR-CA. An H/CL threshold of ≥ 1.4 maximized specificity (99%) and positive predictive value (93%) but resulted in decreased sensitivity (93%), compared to the ≥ 1.3 threshold which had 100% sensitivity. CONCLUSION: Among patients with a low pretest likelihood of ATTR-CA, planar interpretation, while useful to exclude disease, must be interpreted with caution. H/CL ratio threshold of ≥ 1.3 resulted in clinically important misclassifications. These data suggest that quantitative planar imaging thresholds may not be appropriate to apply in low pretest likelihood populations being evaluated for ATTR-CA.
引用
- Pandey S, Teruya S, Rodriguez C, et al. Diagnostic performance characteristics of planar quantitative and semi-quantitative parameters of Tc99m pyrophosphate (PYP) imaging for diagnosis of transthyretin (ATTR) cardiac amyloidosis: the SCAN-MP study. J Nucl Cardiol. 2023. PMID: 36823486. doi:10.1007/s12350-023-03203-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。