文献速递心脏核医学骨显像与常规 SPECT

在心脏淀粉样变性中利用99mTc-HDP骨显像的心电门控SPECT采集计算左心室射血分数的可行性

Feasibility of Left Ventricle Ejection Fraction Calculation Using Electrocardiographically Gated SPECT Acquisition of 99m Tc-HDP Bone Scintigraphy in Cardiac Amyloidosis.
PubMed 文献 · Clin Nucl Med · 2023-02-17

对6例疑似心脏淀粉样变性患者行骨显像时加做心电门控SPECT采集,评估左心室功能分析的可行性。门控SPECT数据确认示踪剂摄取足以自动勾画心肌轮廓,LVEF估算范围为24%至54%,与既往超声心动图LVEF估算相比总体仅见小差异。作者认为骨显像时的心电门控SPECT采集可能提供有意义的LVEF估算。

要点

  • 6例疑似心脏淀粉样变性患者行骨显像时加做心电门控SPECT采集。
  • 门控SPECT确认示踪剂摄取足以自动勾画心肌轮廓,LVEF估算范围24%至54%。
  • 与既往超声心动图LVEF相比总体仅见小差异,1例两者似不一致,可能反映实际LVEF恶化并经随访超声心动图证实。

核心结论

  • 作者认为骨显像时的心电门控SPECT采集可能提供有意义的LVEF估算。

研究设计与样本

  • 对6例疑似心脏淀粉样变性患者行骨显像,并额外行心电门控SPECT采集以评估左心室功能分析的可行性。

主要发现

  • 心电门控SPECT数据确认示踪剂摄取足以自动勾画心肌轮廓。
  • LVEF估算范围为24%至54%。
  • 与既往超声心动图LVEF估算相比总体仅见小差异。
  • 1例患者两种方法的LVEF测量似不一致,可能反映实际LVEF恶化,并经随访超声心动图证实。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

We performed bone scintigraphy in 6 patients with suspected cardiac amyloidosis. To evaluate feasibility of left ventricle function analysis, we additionally performed electrocardiographically gated SPECT acquisition. The cardiac-gated SPECT data confirmed adequate tracer uptake for automatic myocardial contour determination. LVEF estimations ranged between 24% and 54%. Comparison with LVEF estimations from prior echocardiography generally showed only small differences. In one patient, the LVEF measurements from both methods seemed discordant, probably reflecting actual LVEF worsening, which was confirmed at follow-up echocardiography. Therefore, our results may suggest that cardiac-gated SPECT acquisition at bone scintigraphy can provide meaningful estimates of LVEF.

来源:Clin Nucl Med,查看原文。版权归原作者所有。

引用

  1. Te Beek ET, Lafeber A, Postema JWA, et al. Feasibility of Left Ventricle Ejection Fraction Calculation Using Electrocardiographically Gated SPECT Acquisition of 99m Tc-HDP Bone Scintigraphy in Cardiac Amyloidosis. Clin Nucl Med. 2023. PMID: 36800245. doi:10.1097/RLU.0000000000004597

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。