文献速递肿瘤 PET/CT神经核医学

68Ga-DOTATATE与18F-FDG双示踪剂PET/MR来源的MR衍生ADCmin值替代FDG PET评估胰腺神经内分泌肿瘤分级与分期的潜在应用

The potential application of MR-derived ADCmin values from 68Ga-DOTATATE and 18F-FDG dual tracer PET/MR as replacements for FDG PET in assessment of grade and stage of pancreatic neuroendocrine tumors.
PubMed 文献 · EJNMMI Res · 2023-02-08

回顾性纳入46例经组织学确诊的胰腺神经内分泌肿瘤患者,于2020年4月至2022年5月行68Ga-DOTATATE与18F-FDG PET/MR。结果显示ADCmin与FDG PET参数(FSUVmax、MTV、TLG)呈负相关,ADCmin可能替代FDG PET用于PNET分期与分级。

要点

  • PNET分级越高,FSUVmax、MTV、TLG值越高(P<0.05)。
  • ADCmin与FSUVmax(r=-0.52)、MTV(r=-0.50)、TLG(r=-0.56)均呈负相关,P<0.001。
  • TLG、SRD、ADCmin、ADCmean与N分期相关,SRD、MTV、ADCmin、TLG、ADCmean与M分期相关。

核心结论

  • FDG PET衍生参数与ADCmin之间存在显著相关关系。
  • ADCmin可能作为替代FDG PET用于PNET分期与分级的工具。
  • 在原发性PNET分级与分期时,单独68Ga-DOTATATE PET/MR可能是双示踪剂PET/MR的足够替代方案。

研究设计与样本

  • 回顾性研究,纳入2020年4月至2022年5月间46例经组织学确诊的胰腺神经内分泌肿瘤患者,行68Ga-DOTATATE与18F-FDG PET/MR成像。

主要发现

  • PNET分级越高与FSUVmax、MTV、TLG值越高相关(P<0.05)。
  • TLG、SRD、ADCmin、ADCmean与N分期相关;SRD、MTV、ADCmin、TLG、ADCmean与M分期相关。
  • ADCmin与FSUVmax呈负相关(r=-0.52;P<0.001),与MTV呈负相关(r=-0.50;P<0.001),与TLG呈负相关(r=-0.56;P<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To evaluate the utility of 68Ga-DOTATATE and 18F-FDG PET/MR for prediction of grade and stage of pancreatic neuroendocrine tumors (PNETs), and to examine the correlation between parameters obtained from FDG PET and diffusion-weighted imaging (DWI) MR parameters. METHODS: A retrospective study using 68Ga-DOTATATE and 18F-FDG PET/MR imaging was performed between April 2020 and May 2022 on 46 individuals with histologically confirmed PNETs. Metabolic tumor volume (MTV), maximum standardized uptake value (FSUVmax), and tumor lesion glycolysis (TLG) for FDG; somatostatin receptor density (SRD), maximum standardized uptake value (GSUVmax), and total lesion somatostatin receptor density (TLSRD) for DOTATATE; and minimum and mean apparent diffusion coefficient (ADCmin and ADCmean) values for MRI, respectively. We performed Spearman's correlation analysis to examine the links between these variables and primary tumor stage and grading. RESULTS: Higher PNET grading was associated with higher FSUVmax, MTV, and TLG values (P < 0.05). TLG, SRD, ADCmin, and ADCmean values were correlated with N staging, while SRD, MTV, ADCmin, TLG, and ADCmean were associated with M staging. Notably, ADCmin was a negative correlation between FSUVmax (r = - 0.52; P < 0.001), MTV (r = - 0.50; P < 0.001), and TLG (r = - 0.56; P < 0.001). CONCLUSIONS: This study highlights significant correlative relationships between FDG PET-derived parameters and ADCmin. ADCmin may offer utility as a tool for PNET staging and grading in lieu of FDG PET. 68Ga-DOTATATE PET/MR alone may be a sufficient alternative to dual tracer PET/MR when conducting grading and staging of primary PNETs.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Gao J, Xu S, Ju H, et al. The potential application of MR-derived ADCmin values from 68Ga-DOTATATE and 18F-FDG dual tracer PET/MR as replacements for FDG PET in assessment of grade and stage of pancreatic neuroendocrine tumors. EJNMMI Res. 2023. PMID: 36752942. doi:10.1186/s13550-023-00960-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。