PubMed 文献 · Eur J Nucl Med Mol Imaging · 2023-02-23

本研究评估[68 Ga]Ga-DOTA-FAPI-04 PET/CT诊断髋关节假体周围感染(PJI)的效能,共纳入103例有症状的髋关节置换术后患者,其中28例为PJI。以2018年循证验证标准为参考,SUVmax曲线下面积为0.898,优于所有血清学检测;摄取模式标准的灵敏度、特异度和准确率分别为100%、93.1%和95%。影像组学分析显示PJI与无菌性失败的组学特征存在显著差异。

要点

  • SUVmax诊断PJI的曲线下面积为0.898,优于所有血清学检测。
  • SUVmax cutoff值为7.53时,灵敏度100%、特异度72%。
  • 摄取模式标准的灵敏度100%、特异度93.1%、准确率95%。

核心结论

  • [68 Ga]Ga-DOTA-FAPI-04 PET/CT诊断PJI显示出有前景的结果,摄取模式诊断标准更具临床指导意义。
  • 影像组学在PJI领域也显示出一定应用前景。

研究设计与样本

  • 前瞻性纳入2019年12月至2022年7月有症状的髋关节置换术后患者,行[68 Ga]Ga-DOTA-FAPI-04 PET/CT检查,共103例,其中28例为PJI。
  • 参考标准基于2018年循证验证标准,采用SUVmax和摄取模式两种诊断标准诊断PJI。
  • 原始数据导入IKT-snap绘制感兴趣视图,A.K.用于提取临床病例特征,并按组进行无监督聚类分析。
  • 试验注册号ChiCTR2000041204,注册日期2019年9月24日。

主要发现

  • SUVmax的曲线下面积为0.898,优于所有血清学检测。
  • SUVmax cutoff值为7.53,灵敏度100%、特异度72%。
  • 摄取模式诊断PJI的灵敏度100%、特异度93.1%、准确率95%。
  • 影像组学分析中,PJI特征与无菌性失败特征存在显著差异。

关键数值与推荐

  • SUVmax诊断PJI的cutoff值为7.53,灵敏度100%、特异度72%。
  • 摄取模式诊断PJI的灵敏度100%、特异度93.1%、准确率95%。
  • SUVmax曲线下面积为0.898,优于所有血清学检测。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess the efficiency of [68 Ga]Ga-DOTA-FAPI-04 in diagnosing periprosthetic hip joint infection and establish a diagnostic standard of clinical significance based on uptake pattern. METHODS: [68 Ga]Ga-DOTA-FAPI-04 PET/CT was performed in patients with symptomatic hip arthroplasty from December 2019 to July 2022. The reference standard was based on the 2018 Evidence-Based and Validation Criteria. Two diagnostic criteria, SUVmax and uptake pattern, were used to diagnose PJI. Meanwhile, original data were imported into IKT-snap to draw the view of interest, A.K. was used to extract features of clinical cases, and unsupervised clustering analysis was applied according to the groups. RESULTS: A total of 103 patients were included, 28 of whom had PJI. The area under the curve of SUVmax was 0.898, which was better than that of all of the serological tests. The cutoff value of SUVmax was 7.53, and the sensitivity and specificity were 100 and 72%, respectively. The sensitivity, specificity and accuracy of the uptake pattern were 100, 93.1 and 95%, respectively. In radiomics analysis, the features of PJI were significantly different from those of aseptic failure. CONCLUSION: The efficiency of [68 Ga]Ga-DOTA-FAPI-04 PET/CT in diagnosing PJI showed promising results, and the diagnostic criteria of the uptake pattern were more clinically instructive. Radiomics also showed certain application prospects in the field of PJI. TRIAL REGISTRATION NUMBER: Trial registration: ChiCTR2000041204. Registered 24 September 2019.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Wang Y, Wang R, Zhang X, et al. Diagnostic efficiency of [68 Ga]Ga-DOTA-FAPI-04 in differentiating periprosthetic hip joint infection and aseptic failure. Eur J Nucl Med Mol Imaging. 2023. PMID: 36813979. doi:10.1007/s00259-023-06146-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。