文献速递心脏核医学

使用铷-82心肌灌注显像评估心肌功能时8门控与16门控心电图重建的性能比较:在年轻健康人群中的发现

Performance of 8- vs 16 ECG-gated reconstructions in assessing myocardial function using Rubidium-82 myocardial perfusion imaging: Findings in a young, healthy population.
PubMed 文献 · J Nucl Cardiol · 2023-01-28

本研究纳入25名健康志愿者(中位年龄23岁),采用铷-82 PET/CT进行重复心肌灌注显像,比较8门控与16门控心电图重建对左心室射血分数(LVEF)、LVEF储备及其重复性的影响。结果显示两种门控重建的LVEF和LVEF储备估计值相似,重复性也相似;结论认为若仅需容积评估,8门控和16门控可互换使用,但若关注充盈和排空速率,则至少应采用16门控。

要点

  • 在健康志愿者中,8门控与16门控重建的静息和负荷LVEF及LVEF储备估计值相似。
  • 8门控与16门控重建的静息、负荷LVEF及LVEF储备的重复性 measures 相似。
  • 若仅需容积评估,8门控和16门控可互换使用;若关注充盈和排空速率,则至少应采用16门控。

核心结论

  • 在健康受试者中,若仅需要容积评估,8门控和16门控心电图重建可以互换使用;但如果关注充盈和排空速率,则应至少采用16门控。

研究设计与样本

  • 研究纳入25名健康志愿者(中位年龄23岁),接受重复的铷-82 PET/CT心肌灌注显像检查。
  • 报告了8门控和16门控心电图重建获得的LVEF、LVEF储备(负荷LVEF减静息LVEF)及其重复性测量(RMS方法)。

主要发现

  • 8门控与16门控重建的LVEF相似:静息LVEF为61±6%对64±6%,负荷LVEF为68±7%对71±6%,LVEF储备为8±3%对6±4%,所有P≥0.13。
  • 静息和负荷LVEF及其储备的重测重复性测量相似:LVEF静息为4.5对4.6(P=0.81),负荷为3.5对3.2(P=0.33),LVEF储备为46.7对49.3(P=0.13)。

临床怎么用

  • 作者认为,在健康受试者中,若仅需容积评估,8门控和16门控心电图重建可互换使用;若关注充盈和排空速率,则至少应采用16门控。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Current imaging guidelines recommend using at least 16 ECG gates when performing MUGA and cardiac SPECT to assess left ventricular ejection fraction (LVEF). However, for Rubidium-82 (82Rb) PET, 8 ECG-gated reconstructions have been a mainstay. This study investigated the implications of quantitative assessments when employing 16 gate, instead of 8 gate, reconstructions for 82Rb myocardial perfusion imaging (MPI). METHODS: The study comprised 25 healthy volunteers (median age 23 years) who underwent repeat MPI sessions employing 82Rb PET/CT. We report LVEF, its reserve (stress LVEF - rest LVEF), and their repeatability measures (RMS method) obtained for 8- and 16 ECG-gated reconstructions. RESULTS: Similar LVEF and LVEF reserve estimates were found for the 8- and 16-gated reconstructions ([%] LVEF (8/16 gates): rest = 61 ± 6/64 ± 6, stress = 68 ± 7/71 ± 6, LVEF reserve (8/16 gates): 8 ± 3/6 ± 4, and all P ≥ 0.13). Similar test-retest repeatability measures were observed for rest and stress LVEF and their reserves [LVEF (8/16 gates); Rest = 4.5/4.6 (P = 0.81), Stress = 3.5/3.2 (P = 0.33), LVEF reserve = 46.7/49.3 (P = 0.13)]. CONCLUSION: In healthy subjects, 8 and 16 ECG gates can be used interchangeably if only volumetric assessments are desired. However, if filling and emptying rates are of interest, a minimum of 16 ECG gates should be employed.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Lassen ML, Wissenberg M, Byrne C, et al. Performance of 8- vs 16 ECG-gated reconstructions in assessing myocardial function using Rubidium-82 myocardial perfusion imaging: Findings in a young, healthy population. J Nucl Cardiol. 2023. PMID: 36708439. doi:10.1007/s12350-022-03193-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。