文献速递心脏核医学骨显像与常规 SPECT

经定量SPECT/CT与半定量平面参数验证的ATTR患者心脏DPD摄取时间依赖性

Cardiac DPD-uptake time dependency in ATTR patients verified by quantitative SPECT/CT and semiquantitative planar parameters.
PubMed 文献 · J Nucl Cardiol · 2022-12-13

本研究在转甲状腺素蛋白相关淀粉样变性(ATTR)患者中评估DPD骨显像的心脏摄取随时间变化。23例患者平面显像示注射后1小时心脏总计数和心/全身比值均显著高于3小时;另15例定量SPECT/CT示心肌SUVpeak在1小时也显著高于3小时。心脏DPD活性与心肌SUVpeak具有时间依赖性,定量骨显像时应考虑此因素。

要点

  • 23例ATTR患者平面显像:注射后1小时心脏总计数和心/全身比值均显著高于3小时。
  • 15例定量SPECT/CT:注射后1小时心肌SUVpeak中位数显著高于3小时。
  • 心脏DPD活性与心肌SUVpeak呈时间依赖性,定量骨显像需考虑显像时机。

核心结论

  • 心脏DPD活性与心肌SUVpeak具有时间依赖性,在ATTR患者中使用定量骨显像时应考虑这一因素。

研究设计与样本

  • 研究纳入23例接受DPD骨显像的患者,于注射后1小时和3小时行平面全身显像,计算经衰变校正的心脏总计数几何均值及心/全身比值(H/WB)。
  • 另纳入15例患者,于注射后1小时和3小时行定量SPECT/CT显像,评估心肌SUVpeak。

主要发现

  • 心脏总计数在注射后1小时为81,676 cts(范围69,887至93,091 cts),3小时为64,819 cts(范围52,048至86,123 cts),P = .0005。
  • 心/全身比值在注射后1小时为0.076 ± 0.020,3小时为0.070 ± 0.022,P = .0003。
  • 心肌SUVpeak中位数在注射后1小时为12.2(范围9.6至18.9),3小时为9.6(范围8.2至15.0),P = 0.0012。

临床怎么用

  • 原文结论指出,心脏DPD活性与心肌SUVpeak具有时间依赖性,在ATTR患者中使用定量骨显像时应考虑这一因素。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Bone scintigraphy plays an important role in the diagnosis of cardiac Transthyretin-Related Amyloidosis (ATTR). The mechanism of myocardial tracer accumulation and its dependence over time are not fully understood. Recently, a scintigraphic quantification of the cardiac amyloid deposition has been discussed. Nevertheless, little is known regarding the right time of quantitative imaging. METHODS: The geometrical mean of decay corrected total counts over the heart and the heart/whole-body ratio (H/WB) were evaluated in 23 patients undergoing DPD-bone scan with planar whole-body images 1 and 3 hours post injection (p.i.). Myocardial standard uptake values (SUV)peak were assessed in another 15 patients with quantitative SPECT/CT imaging 1 hours and 3 hours p.i.. RESULTS: Total counts over the heart (1 hours p.i.: 81,676 cts, range 69,887 to 93,091 cts and 3 hours p.i.: 64,819 cts, range 52,048 to 86,123 cts, P = .0005) and H/WB ratio (1 hours p.i.:0.076 ± 0.020 and 3 hours p.i. 0.070 ± 0.022; P = .0003) were significantly increased 1 hours p.i.. Furthermore median myocardial SUVpeak (1 hours p.i.:12.2, range 9.6 to 18.9 and 3 hours p.i.: 9.6, range 8.2 to 15.0, P = 0.0012) was also significantly higher after 1 hours p.i. compared to 3 hours p.i.. CONCLUSION: Cardiac DPD activity and myocardial SUVpeak are time-dependent, which should be considered when using quantitative bone scintigraphy in ATTR patients.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Wollenweber T, Rettl R, Kretschmer-Chott E, et al. Cardiac DPD-uptake time dependency in ATTR patients verified by quantitative SPECT/CT and semiquantitative planar parameters. J Nucl Cardiol. 2022. PMID: 36513919. doi:10.1007/s12350-022-03149-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。