文献速递神经核医学肿瘤 PET/CT

动态[18F]FE-PE2I PET估算相对区域脑血流的验证:与[15O]H2O PET的比较

Validation of dynamic [18F]FE-PE2I PET for estimation of relative regional cerebral blood flow: a comparison with [15O]H2O PET.
PubMed 文献 · EJNMMI Res · 2022-11-17

本研究以[15O]H2O PET测量的脑灌注为参考,验证多巴胺转运体示踪剂[18F]FE-PE2I是否能同时估算相对区域脑血流。在29例近期起病的帕金森综合征患者和30名健康对照中,FE-PE2I的R1与H2O的F在额叶、顶叶、颞叶、扣带回、枕叶皮质及纹状体呈强线性相关(r≥0.731-0.905,p<0.001),ICC为0.727-0.943(p<0.001)。作者认为FE-PE2I或可作为脑灌注的替代指标,在一次动态扫描中同时评估多巴胺转运体可用性和相对区域脑血流。

要点

  • FE-PE2I的R1与[15O]H2O的F在皮质和纹状体呈强线性相关(r≥0.731-0.905,p<0.001)。
  • R1与F的ICC为0.727-0.943(p<0.001),一致性良好至优秀。
  • 作者认为FE-PE2I或可作为脑灌注的替代指标,在一次动态扫描中同时评估DAT可用性和rCBFR。

核心结论

  • 作者认为FE-PE2I或可作为脑灌注的替代指标,在一次动态扫描中同时评估多巴胺转运体可用性和相对区域脑血流,可能对帕金森综合征的鉴别诊断有价值。

研究设计与样本

  • 本研究纳入29例近期起病的帕金森综合征患者和30名健康对照,比较FE-PE2I与H2O两种PET示踪剂的动态成像数据。
  • FE-PE2I的R1采用简化参考组织模型计算,H2O的F采用改良Koopman双重积分法计算。

主要发现

  • 在全部受试者中,R1与F在额叶、顶叶、颞叶、扣带回、枕叶皮质及纹状体呈强线性相关(r≥0.731-0.905,p<0.001)。
  • R1与F的ICC为0.727-0.943(p<0.001),一致性良好至优秀。

关键数值与推荐

  • FE-PE2I的R1与H2O的F线性相关:r≥0.731-0.905(p<0.001)。
  • R1与F的ICC为0.727-0.943(p<0.001)。

临床怎么用

  • 原文结论未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Dopamine transporter (DAT) imaging is used in the diagnostic work-up in suspected parkinsonian syndromes and dementia with Lewy bodies but cannot differentiate between these syndromes, and an extra brain imaging examination of the regional cerebral blood flow (rCBF) or glucose metabolism is often needed for differential diagnosis. The requirement of two different imaging examinations is resource-consuming and inconvenient for the patients. Therefore, imaging of both cortical blood flow and DAT imaging with the same radiotracer would be more convenient and cost-effective. The aim of this study was to test whether relative regional cerebral blood flow (rCBFR) can be measured with the DAT-specific positron emission tomography (PET) tracer [18F]FE-PE2I (FE-PE2I), by validation with cerebral perfusion measured with [15O]H2O PET (H2O). METHODS: The rCBFR was quantified by kinetic modeling for FE-PE2I (R1) and H2O (F). The R1 was calculated using the simplified reference tissue model, and F was calculated with a modified Koopman double-integration method. The linear relationship and intraclass correlation (ICC) between R1 and F were tested in image data derived from 29 patients with recent onset parkinsonism and 30 healthy controls. RESULTS: There was a strong linear correlation across all subjects between R1 and F in the frontal, parietal, temporal, cingulate and occipital cortex as well as in the striatum (r ≥ 0.731-0.905, p < 0.001) with a good-to-excellent ICC, ranging from 0.727 to 0.943 (p < 0.001). CONCLUSIONS: Our results suggest that FE-PE2I may be used as a proxy for cerebral perfusion, thus potentially serving as a radiotracer for assessment of both DAT availability and rCBFR in one single dynamic scan. This could be valuable in the differential diagnosis of parkinsonian syndromes. TRIAL REGISTRATION: EUDRA-CT 2015-003045-26. Registered 23 October 2015 https://www.clinicaltrialsregister.eu/ctr-search/search?query=2015-003045-26.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Jakobson Mo S, Axelsson J, Stiernman L, et al. Validation of dynamic [18F]FE-PE2I PET for estimation of relative regional cerebral blood flow: a comparison with [15O]H2O PET. EJNMMI Res. 2022. PMID: 36394638. doi:10.1186/s13550-022-00941-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。