一次性注射器类型选择对[99mTc]Tc-替曲膦心肌灌注显像操作的影响
该研究在临床环境中测量了[99mTc]Tc-替曲膦在3种注射器中的残留活性,发现润滑注射器残留活性显著更高(均值±标准差26.12±10.21%,P<.001),且主要位于润滑的管身,并对患者采集的标准化计数时长产生正向显著影响。作者结论认为应避免使用高残留活性的润滑注射器,因其增加延长患者采集时间和潜在图像质量不佳的风险。
要点
- 润滑注射器的[99mTc]Tc-替曲膦残留活性显著更高,均值±标准差26.12±10.21%(P<.001)。
- 润滑注射器的残留活性主要位于润滑的管身。
- 润滑注射器对患者采集的标准化计数时长有正向显著影响。
核心结论
- 作者认为应避免使用高残留活性的润滑注射器,因其增加延长患者采集时间和潜在图像质量不佳的风险。
研究设计与样本
- 在临床环境中测量[99mTc]Tc-替曲膦在3种注射器中的残留活性:3件式润滑注射器、3件式非润滑注射器和2件式注射器,每种注射器n≥30。
- 使用CzT SPECT相机定位并定量残留活性,同时进行放射性计数,并与不同临床参数进行相关性分析及多元线性回归分析。
主要发现
- 所有注射器类型的残留活性不同,但润滑注射器显示显著更高水平,均值±标准差26.12±10.21%(P<.001)。
- 对于润滑注射器,残留活性主要位于润滑的管身。
- 润滑注射器对患者采集的标准化计数时长有正向且显著的影响。
临床怎么用
- 作者认为应避免使用高残留活性的润滑注射器,因其增加延长患者采集时间和潜在图像质量不佳的风险。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Residual activity in dispensing syringes is a problem that has been sporadically reported with various radiopharmaceuticals. Studies with [99mTc]Tc-tetrofosmin are non-consistent so far. The aim was to quantify the residual activity of [99mTc]Tc-tetrofosmin in different syringes in a clinical setting and to assess its impact on the clinical imaging procedure. METHODS: The residual activity of [99mTc]Tc-tetrofosmin was measured in 3 types of syringes: 3-part lubricated and non-lubricated syringes and 2-part syringe (n ≥ 30 for each syringe). The residual activity was located and quantified using a CzT SPECT camera and radio-counting then was correlated with different clinical parameters and processed by multiple linear regression analysis. RESULTS: Residual activity was different in all syringe types but lubricated syringes showed significantly higher levels with a mean ± SD of 26.12 ± 10.21% (P < .001). For these syringes, the residual activity was mainly located on the lubricated body. They also have a positive and significant impact on the standardized counting duration of patients' acquisitions. CONCLUSION: Lubricated syringes with high residual activity should be avoided as they increase the risk of prolonging patient acquisition time and potentially increasing the risk of poor image quality.
引用
- Ladriere T, Desmonts C, Zimmermann PA, et al. Impact of disposable syringes type choice on myocardial perfusion imaging procedures with [99mTc]Tc-tetrofosmin. J Nucl Cardiol. 2022. PMID: 36352084. doi:10.1007/s12350-022-03143-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。