18F-PSMA切伦科夫发光与柔性放射自显影成像在前列腺癌小鼠模型中的研究及男性根治性前列腺切除术可行性研究的初步结果
在高危前列腺癌中,术中识别阳性切除边缘(PRM)需改进。研究评估18F-PSMA-1007的切伦科夫发光成像(CLI)与柔性放射自显影(FAR)CLI,小鼠模型(n=5)中CLI未检出病灶而FAR CLI全部检出,最低活度浓度7.25 kBq/mL(CNR 5.48);7例根治性前列腺切除术患者中FAR CLI在6例可检出信号,检出限至少2.06 kBq/mL,但2例PRM均未被CLI或FAR CLI预测。
要点
- 小鼠模型中FAR CLI检出全部5只小鼠的病灶,CLI未检出任何病灶。
- 7例患者中FAR CLI在6例检出信号,检出限至少2.06 kBq/mL。
- 组织病理学显示2例PRM,CLI与FAR CLI均未预测到。
核心结论
- 18F-PSMA FAR CLI在示踪剂相关信号可检测性上优于CLI。
- 根治性前列腺切除术中前列腺癌可被可视化至2.06 kBq/mL。
- 然而PRM的检测有限。
- 由于闪烁体覆盖,FAR CLI的直接解剖学关联具有挑战性。
研究设计与样本
- 小鼠模型:皮下种植PSMA高亲和RM1-PGLS肿瘤的小鼠(n=5)给予18F-PSMA-1007后行PET/CT,处死后切除器官行CLI与FAR CLI,信号与PET/CT获得的示踪剂活度浓度(AC)相关。
- 临床可行性研究:7例高危前列腺癌患者术前行18F-PSMA PET/CT后立即行根治性前列腺切除术,在完整标本及索引病灶切开后计算两种成像方式的对比噪声比(CNR)。
主要发现
- 异位体内小鼠模型(n=5)中,CLI未检出任何病灶;FAR CLI在全部小鼠中检出清晰信号,最低AC为7.25 kBq/mL(CNR 5.48)。
- 前列腺标本索引病灶切开后,CLI在癌区未观察到信号增高;FAR CLI在7例患者中6例可检出信号。
- 漏检索引病灶的AC为1.85 kBq/mL,导致检出限至少为2.06 kBq/mL。
- 组织病理学显示2例PRM,CLI与FAR CLI均未预测到。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- PRM的检测有限。
- 由于闪烁体覆盖,FAR CLI的直接解剖学关联具有挑战性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Intraoperative identification of positive resection margins (PRMs) in high-risk prostate cancer (PC) needs improvement. Cerenkov luminescence imaging (CLI) with 68Ga-PSMA-11 is promising, although limited by low residual activity and artificial signals. Here, we aimed to assess the value of CLI and flexible autoradiography (FAR) with 18F-PSMA-1007. Methods: Mice bearing subcutaneous PSMA-avid RM1-PGLS tumors were administered 18F-PSMA-1007, and PET/CT was performed. After the animals had been killed, organs were excised and measured signals in CLI and FAR CLI were correlated with tracer activity concentrations (ACs) obtained from PET/CT. For clinical assessment, 7 high-risk PC patients underwent radical prostatectomy immediately after preoperative 18F-PSMA PET/CT. Contrast-to-noise ratios (CNRs) were calculated for both imaging modalities in intact specimens and after incision above the index lesion. Results: In the heterotopic in vivo mouse model (n = 5), CLI did not detect any lesion. FAR CLI detected a distinct signal in all mice, with a lowest AC of 7.25 kBq/mL (CNR, 5.48). After incision above the index lesion of the prostate specimen, no increased signal was observed at the cancer area in CLI. In contrast, using FAR CLI, a signal was detectable in 6 of 7 patients. The AC in the missed index lesion was 1.85 kBq/mL, resulting in a detection limit of at least 2.06 kBq/mL. Histopathology demonstrated 2 PRMs, neither of which was predicted by CLI or FAR CLI. Conclusion: 18F-PSMA FAR CLI was superior to CLI in tracer-related signal detectability. PC was could be visualized in radical prostatectomy down to 2.06 kBq/mL. However, the detection of PRMs was limited. Direct anatomic correlation of FAR CLI is challenging because of the scintillator overlay.
引用
- Costa PF, Püllen L, Kesch C, et al. 18F-PSMA Cerenkov Luminescence and Flexible Autoradiography Imaging in a Prostate Cancer Mouse Model and First Results of a Radical Prostatectomy Feasibility Study in Men. J Nucl Med. 2022. PMID: 36357181. doi:10.2967/jnumed.122.264670
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。