本研究对因怀疑心脏结节病或心肌炎行68Ga-DOTANOC PET/CT且视觉评估与心脏MRI均正常的患者进行半定量分析,注射111-185 MBq后45-60分钟采集,得出各心肌节段SUVmax_lbm及心肌与血池比值,并以比值第95百分位作为正常上限,认为正常心肌可存在生理性摄取,所建参考值可作为视觉评估的辅助工具。

要点

  • 正常心肌可存在68Ga-DOTANOC生理性摄取。
  • 室间隔、前壁、近侧壁、远侧壁、下壁、心尖SUVmax_lbm分别为1.12±0.39、1.09±0.42、1.26±0.49、1.16±0.40、1.23±0.39、1.05±0.40。
  • 相应区域心肌SUVmax_lbm与血池SUVmean_lbm比值第95百分位分别为1.70、1.70、2.00、1.95、2.05、1.70,作为正常上限。

核心结论

  • 正常心肌可存在68Ga-DOTANOC生理性摄取,本研究建立的半定量参数参考值可作为疑似心脏结节病或心肌炎患者视觉评估的辅助工具。

研究设计与样本

  • 对因评估心脏结节病或心肌炎行68Ga-DOTANOC PET/CT、视觉评估与心脏MRI均正常的患者进行半定量分析,注射111-185 MBq后45-60分钟采集。

主要发现

  • 室间隔、前壁、近侧壁、远侧壁、下壁、心尖的SUVmax_lbm分别为1.12±0.39、1.09±0.42、1.26±0.49、1.16±0.40、1.23±0.39、1.05±0.40。
  • 相应区域心肌SUVmax_lbm与血池SUVmean_lbm比值第95百分位分别为1.70、1.70、2.00、1.95、2.05、1.70。

关键数值与推荐

  • 以心肌SUVmax_lbm与血池SUVmean_lbm比值的第95百分位作为正常上限,各区域分别为1.70、1.70、2.00、1.95、2.05、1.70。

临床怎么用

  • 作者认为本研究建立的半定量参数参考值可作为疑似心脏结节病或心肌炎患者68Ga-DOTANOC PET/CT视觉评估的辅助工具。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To ascertain presence of physiological uptake and derive standardized uptake values (SUV) of 68Ga-DOTANOC in normal myocardium and establish reference values. METHODS AND RESULTS: Dedicated cardiac 68Ga-DOTANOC PET/CT studies of patients referred for evaluation of cardiac sarcoidosis (CS) or myocarditis and found to be normal on visual assessment and on cardiac MRI were analyzed semiquantitatively. The studies were acquired 45-60 minutes after intravenous injection of 111-185 MBq of 68Ga-DOTANOC. Myocardial SUVmax normalized to lean body mass (SUVmax_lbm) values for septum, anterior wall, proximal lateral wall, distal lateral wall, inferior wall, and apical region were 1.12 ± .39, 1.09 ± .42, 1.26 ± .49, 1.16 ± .40, 1.23 ± .39, and 1.05 ± .40, respectively. Myocardial SUVmax_lbm-to-blood pool SUVmean_lbm ratios were calculated for each region and 95th percentile values of these ratios were considered the upper limit of normal. 95th percentile values of myocardial SUVmax_lbm-to-blood pool SUVmean_lbm ratio for the corresponding regions were 1.70, 1.70, 2.00 1.95, 2.05, and 1.70, respectively. CONCLUSION: There can be physiological uptake of 68Ga-DOTANOC in normal myocardium and the reference values of semiquantitative parameters established in this study may be employed as a corroborative tool for visual assessment in patients undergoing 68Ga-DOTANOC PET/CT for suspected CS or myocarditis.