文献速递心脏核医学

低剂量冠状动脉钙化评分与标准方案的比较

Low-dose coronary artery calcium scoring compared to the standard protocol.
PubMed 文献 · J Nucl Cardiol · 2022-10-26

研究纳入1511例疑似冠心病行心肌灌注显像的患者,比较80 kVp低剂量与120 kVp标准CT的冠状动脉钙化评分(CACS)。两种方案评分相关性很好(R=0.94),但低剂量方案系统性低估CACS,且CACS=0的患者比例在两种方案间存在差异,可能影响钙化评分的预后价值及「零钙化」的意义。

要点

  • 80 kVp与120 kVp计算的CACS相关性很好(R=0.94,R2=0.88,P<.001)。
  • 低剂量方案系统性低估CACS,Bland-Altman偏倚为-154.2,一致性界限-563.5至871.9。
  • CACS=0的患者数在两种方案间存在差异(n=264 vs 437,P<.001)。

核心结论

  • 在大型患者人群中,尽管标准与低剂量CT计算的CACS相关性良好,但低剂量方案系统性低估CACS。
  • 这种低估可能影响钙化评分的预后价值,若用低剂量CT评估CACS,既有的「零钙化力量」可能不再成立。

研究设计与样本

  • 纳入疑似冠心病行心肌灌注显像(MPS)的患者,均接受120 kVp标准CACS评估和80 kVp低剂量CACS评估。
  • 生成低剂量与标准两套数据集进行比较,记录风险分类(0至25、25至50、50至75、75至90、>90%),共纳入1511例患者(793例男性,年龄69±9.1岁)。

主要发现

  • 120 kVp与80 kVp计算的评分相关性很好(R=0.94,R2=0.88,P<.001),Bland-Altman一致性界限为-563.5至871.9,偏倚为-154.2。
  • 被归入<25%百分位类别的患者比例在两种方案间存在差异(P=.03)。
  • CACS=0的患者数在两种方案间存在差异(n=264 vs 437,P<.001)。

关键数值与推荐

  • 风险分类类别:0至25%、25至50%、50至75%、75至90%、>90%。
  • 两种方案评分相关性:R=0.94,R2=0.88,P<.001。
  • Bland-Altman一致性界限:-563.5至871.9,偏倚-154.2。
  • CACS=0患者数:n=264 vs 437,P<.001。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We aimed to compare coronary artery calcium scoring (CACS) with computed tomography (CT) with 80 and 120 kVp in a large patient population and to establish whether there is a difference in risk classification between the two scores. METHODS: Patients with suspected CAD undergoing MPS were included. All underwent standard CACS assessment with 120-kVp tube voltage and with 80 kVp. Two datasets (low-dose and standard) were generated and compared. Risk classes (0 to 25, 25 to 50, 50 to 75, 75 to 90, and > 90%) were recorded. RESULTS: 1511 patients were included (793 males, age 69 ± 9.1 years). There was a very good correlation between scores calculated with 120 and 80 kVp (R = 0.94, R2 = 0.88, P < .001), with Bland-Altman limits of agreement of - 563.5 to 871.9 and a bias of - 154.2. The proportion of patients assigned to the < 25% percentile class (P = .03) and with CACS = 0 differed between the two protocols (n = 264 vs 437, P < .001). CONCLUSION: In a large patient population, despite a good correlation between CACS calculated with standard and low-dose CT, there is a systematic underestimation of CACS with the low-dose protocol. This may have an impact especially on the prognostic value of the calcium score, and the established "power of zero" may no longer be warranted if CACS is assessed with low-dose CT.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Allio IR, Caobelli F, Popescu CE, et al. Low-dose coronary artery calcium scoring compared to the standard protocol. J Nucl Cardiol. 2022. PMID: 36289163. doi:10.1007/s12350-022-03120-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。