文献速递肿瘤 PET/CT放射性药物与辐射防护

超早期快速全身[68Ga]Ga-FAPI-04 PET/CT扫描的可行性

The feasibility of ultra-early and fast total‑body [68 Ga]Ga-FAPI-04 PET/CT scan.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2022-10-29

在仁济医院12例患者中比较注射后5分钟采集30秒的超早期快速全身[68Ga]Ga-FAPI-04 PET/CT与传统注射后60分钟采集300秒成像:传统成像检出的44个病灶超早期快速成像全部检出,12例患者肿瘤分期均未改变,病灶SUVmax无统计学显著差异,血池和肝脏本底SUVmean传统成像较超早期快速成像显著降低。

要点

  • 超早期快速成像(注射后5分钟、采集30秒)与传统成像(注射后60分钟、采集300秒)检出相同病灶,肿瘤分期未改变。
  • 病灶SUVmax超早期快速成像12.5±8.7 vs 传统成像13.7±8.5,P=0.528,无统计学显著差异。
  • 血池SUVmean传统成像4.0±0.6 vs 超早期快速成像0.9±0.2,P<0.001;肝脏SUVmean传统成像2.5±0.7 vs 超早期快速成像1.0±0.5,P<0.001,传统成像显著降低。

核心结论

  • 超早期快速成像与传统[68Ga]Ga-FAPI-04成像相比,肿瘤检出和病灶摄取等效。
  • 超早期快速全身[68Ga]Ga-FAPI-04 PET/CT扫描可满足对长时间水平体位和等待时间耐受差患者的临床诊断需求。

研究设计与样本

  • 在仁济医院对12例患者行全身[68Ga]Ga-FAPI-04 PET/CT,每例均行两种采集:注射后5分钟、采集30秒的超早期快速成像,以及注射后60分钟、采集300秒的传统成像。
  • 平均[68Ga]Ga-FAPI-04注射剂量为1.85 MBq/kg。

主要发现

  • 传统成像在12例患者中检出44个病灶,超早期快速成像全部检出这44个病灶。
  • 12例患者肿瘤分期均未改变,每例两种图像可见相同病灶。
  • 病灶SUVmax超早期快速成像12.5±8.7 vs 传统成像13.7±8.5,P=0.528,无统计学显著差异。
  • 血池SUVmean传统成像4.0±0.6 vs 超早期快速成像0.9±0.2,P<0.001,传统成像显著降低。
  • 肝脏SUVmean传统成像2.5±0.7 vs 超早期快速成像1.0±0.5,P<0.001,传统成像显著降低。

临床怎么用

  • 作者认为超早期快速全身[68Ga]Ga-FAPI-04 PET/CT扫描可满足对长时间水平体位和等待时间耐受差患者的临床诊断需求。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: [68 Ga]Ga-FAPI-04 PET/CT has been widely used in oncology patients. The patients need to lie still for 20-30 min during scan after waiting for 60 min post-tracer injection in traditional [68 Ga]Ga-FAPI-04 PET/CT scan. This is difficult for some patients who are intolerant to prolonged horizontal positioning and waiting time. Therefore, we evaluated the diagnostic value of the images obtained in ultra-early and fast scan (5-min p.i., 30-s acquisition time) by the total-body [68 Ga]Ga-FAPI-04 PET/CT and to investigate whether they could meet the requirements of clinical diagnosis. METHODS: Total-body [68 Ga]Ga-FAPI-04 PET/CT was conducted in 12 patients at the Renji Hospital. Patients underwent PET with two acquisitions: 5-min p.i. and 30-s acquisition time (ultra-early and fast imaging) and 60-min p.i. and 300-s acquisition time (traditional imaging). Mean [68 Ga]Ga-FAPI-04 injection dose was 1.85 MBq/kg. RESULTS: Forty-four lesions were detected in 12 patients on traditional imaging. All the 44 lesions on conventional imaging could also detected by ultra-early and fast imaging. For all the 12 patients, the tumor stage did not change, as same lesions were visible for every case in both images. There was no statistically significant difference in SUVmax of lesions between ultra-early and fast imaging and traditional imaging (12.5 ± 8.7 vs 13.7 ± 8.5, P = 0.528). Background bloodpool (4.0 ± 0.6 vs 0.9 ± 0.2, P < 0.001)and liver (2.5 ± 0.7 vs 1.0 ± 0.5, P < 0.001)at traditional imaging showed a significant decrease in SUVmean compared to ultra-early and fast imaging. CONCLUSIONS: Ultra-early and fast imaging versus traditional [68 Ga]Ga-FAPI-04 imaging resulted in equivalent tumor detection and lesion uptake. Ultra-early and fast total-body [68 Ga]Ga-FAPI-04 PET/CT scan could meet clinical diagnostic requirements for patients with poor tolerant to prolonged horizontal positioning and waiting time.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Chen R, Yang X, Yu X, et al. The feasibility of ultra-early and fast total‑body [68 Ga]Ga-FAPI-04 PET/CT scan. Eur J Nucl Med Mol Imaging. 2022. PMID: 36308535. doi:10.1007/s00259-022-06004-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。