基于NaI(Tl) SPECT的定量心肌血流量评估对显著狭窄的诊断价值:一项前瞻性多中心研究
这项前瞻性多中心研究纳入154例疑似或已知冠心病患者(462支血管),评估基于NaI(Tl) SPECT的心肌血流量(MBF)定量对定量冠状动脉造影(QCA)定义冠心病的诊断价值。应激MBF和心肌血流储备(MFR)在患者水平和血管水平均比常规SPECT心肌灌注显像(MPI)敏感性更高,曲线下面积更大。将定量SPECT指标与MPI整合可显著提高曲线下面积并改善判别与重分类能力。
要点
- 应激MBF和MFR在患者水平敏感性分别为81.6%和72.4%,均高于MPI的51.3%。
- 血管水平应激MBF和MFR敏感性分别为78.6%和75.9%,均高于MPI的31.3%。
- 定量SPECT指标与MPI整合可显著提高曲线下面积并改善判别与重分类能力。
核心结论
- 基于NaI(Tl) SPECT的血流定量在检测显著狭窄方面比MPI具有更优的敏感性和判别能力。
研究设计与样本
- 前瞻性多中心研究,纳入疑似或已知冠心病患者,行药物负荷/静息动态SPECT显像和常规SPECT MPI,随后行QCA。
- 梗阻性病变定义为QCA管腔直径狭窄≥50%。
- 共154例患者(462支血管)纳入分析。
主要发现
- 梗阻性冠心病在76/154例患者(49.4%)和112/462支血管(24.2%)中检出。
- 应激MBF和MFR的最佳截断值分别为1.86 mL/min/g和1.95。
- 患者水平敏感性:应激MBF vs MPI为81.6% vs 51.3%,MFR vs MPI为72.4% vs 51.3%。
- 血管水平敏感性:应激MBF vs MPI为78.6% vs 31.3%,MFR vs MPI为75.9% vs 31.3%(所有P < .01)。
- ROC分析曲线下面积:患者水平应激MBF vs MPI为0.761 vs 0.641,MFR vs MPI为0.770 vs 0.641;血管水平应激MBF vs MPI为0.745 vs 0.613,MFR vs MPI为0.756 vs 0.613(所有P < .05)。
关键数值与推荐
- 应激MBF最佳截断值为1.86 mL/min/g,MFR最佳截断值为1.95。
- 梗阻性冠心病定义为QCA管腔直径狭窄≥50%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The aim of this prospective multi-center study was to investigate the diagnostic value of myocardial blood flow (MBF) quantification using NaI(Tl)-based single-photon emission computed tomography (SPECT) for determining coronary artery disease (CAD) defined by quantitative coronary angiography (QCA). BACKGROUND: Absolute quantitation of MBF and myocardial flow reserve (MFR) using SPECT is clinically feasible; however, whether flow quantification using NaI(Tl) SPECT is superior to commonly performed SPECT myocardial perfusion imaging (MPI) in determining CAD has not been evaluated. METHODS: Patients with suspected or known CAD underwent pharmacological stress/rest dynamic SPECT imaging and routine SPECT MPI followed by QCA. Obstructive disease was defined as ≥ 50% reduction in luminal diameter on QCA. RESULTS: One hundred fifty-four patients (462 vessels) were included in the analysis. Obstructive CAD was detected in 76/154 patients (49.4%) and 112/462 vessels (24.2%). Optimal cut-off values were 1.86 mL/min/g for stress MBF and 1.95 for MFR, respectively. Stress MBF and MFR were more sensitive than MPI in both individual patients (stress MBF vs MPI: 81.6% vs 51.3%; MFR vs MPI: 72.4% vs 51.3%) and in coronary vascular regions (stress MBF vs MPI: 78.6% vs 31.3%; MFR vs MPI: 75.9% vs 31.3%; all P < .01). In receiver operating characteristic curve analysis, quantification revealed a significantly greater area under the curve than MPI at the patient (stress MBF vs MPI: 0.761 vs 0.641; MFR vs MPI: 0.770 vs 0.641) and the vessel (stress MBF vs MPI: 0.745 vs 0.613; MFR vs MPI: 0.756 vs 0.613; all P < .05) levels. Integrating quantitative SPECT measures with MPI significantly increased the area under the curve and improved the discriminatory and reclassification capacity. CONCLUSION: Flow quantification using NaI(Tl) SPECT provides superior sensitivity and discriminatory capacity to MPI in detecting significant stenosis. Clinical trial registration NCT03637725.
引用
- Wang L, Zheng Y, Zhang J, et al. Diagnostic value of quantitative myocardial blood flow assessment by NaI(Tl) SPECT in detecting significant stenosis: a prospective, multi-center study. J Nucl Cardiol. 2022. PMID: 35971031. doi:10.1007/s12350-022-03085-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。