文献速递心脏核医学

基于深度学习在投影域和重建域对低剂量心肌灌注SPECT去噪的研究

Deep learning-based denoising in projection-domain and reconstruction-domain for low-dose myocardial perfusion SPECT.
PubMed 文献 · J Nucl Cardiol · 2022-08-18

本研究评估条件生成对抗网络(cGAN)在投影域(cGAN-prj)和重建域(cGAN-recon)对低剂量心肌灌注SPECT的去噪性能。采用100个XCAT体模模拟64个噪声投影及20例患者回顾性数据,结果显示cGAN去噪较低剂量和传统滤波提升图像质量,且cGAN-prj较cGAN-recon可进一步降低剂量而不损害图像质量。

要点

  • cGAN去噪较低剂量和传统后重建滤波提升心肌灌注SPECT图像质量。
  • cGAN-prj较cGAN-recon可进一步降低剂量而不损害图像质量。
  • 基于cGAN-prj的去噪优于cGAN-recon。

核心结论

  • 基于cGAN-prj的去噪对心肌灌注SPECT优于cGAN-recon。

研究设计与样本

  • 对100个具有不同解剖变异和99mTc-sestamibi分布的XCAT体模模拟64个噪声SPECT投影。
  • 回顾性分析20例接受99mTc-sestamibi负荷SPECT/CT扫描的患者。
  • 通过将全剂量计数率缩放至原始的1/20至1/2获得系列低剂量投影。
  • 对每例患者从全剂量列表模式数据生成低剂量SPECT图像(全剂量的7/10至1/10)。
  • 所有投影均采用定量OS-EM方法重建。

主要发现

  • cGAN去噪较低剂量和传统后重建滤波提升图像质量。
  • cGAN-prj较cGAN-recon可进一步降低剂量水平而不损害图像质量。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Low-dose (LD) myocardial perfusion (MP) SPECT suffers from high noise level, leading to compromised diagnostic accuracy. Here we investigated the denoising performance for MP-SPECT using a conditional generative adversarial network (cGAN) in projection-domain (cGAN-prj) and reconstruction-domain (cGAN-recon). METHODS: Sixty-four noisy SPECT projections were simulated for a population of 100 XCAT phantoms with different anatomical variations and 99mTc-sestamibi distributions. Series of LD projections were obtained by scaling the full dose (FD) count rate to be 1/20 to 1/2 of the original. Twenty patients with 99mTc-sestamibi stress SPECT/CT scans were retrospectively analyzed. For each patient, LD SPECT images (7/10 to 1/10 of FD) were generated from the FD list mode data. All projections were reconstructed by the quantitative OS-EM method. A 3D cGAN was implemented to predict FD images from their corresponding LD images in the projection- and reconstruction-domain. The denoised projections were reconstructed for analysis in various quantitative indices along with cGAN-recon, Gaussian, and Butterworth-filtered images. RESULTS: cGAN denoising improves image quality as compared to LD and conventional post-reconstruction filtering. cGAN-prj can further reduce the dose level as compared to cGAN-recon without compromising the image quality. CONCLUSIONS: Denoising based on cGAN-prj is superior to cGAN-recon for MP-SPECT.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。