静息18F-FDG心肌显像在疑似不稳定型心绞痛中国患者中诊断阻塞性冠状动脉疾病的价值:一项前瞻性真实世界临床研究

Value of rest 18F-FDG myocardial imaging in the diagnosis of obstructive coronary artery disease in Chinese patients with suspected unstable angina: A prospective real-world clinical study.
PubMed 文献 · J Nucl Cardiol · 2022-08-01

该前瞻性研究纳入136例非急性胸痛、心电图正常、肌钙蛋白阴性且疑似不稳定型心绞痛的中国患者,在1周内完成静息18F-FDG PET显像与冠状动脉造影。结果显示,静息18F-FDG显像在患者水平和血管水平诊断阻塞性CAD的灵敏度分别为62.0%和47.7%,特异度分别为92.3%和94.2%,AUC分别为0.771和0.710;在多支血管病变患者中识别罪犯缺血血管的PPV达97.7%。

要点

  • 静息18F-FDG显像诊断阻塞性CAD患者水平灵敏度62.0%、特异度92.3%、AUC 0.771。
  • 血管水平灵敏度47.7%、特异度94.2%、AUC 0.710。
  • 多支血管病变患者中识别罪犯缺血血管的PPV为97.7%。

核心结论

  • 静息18F-FDG显像在疑似不稳定型心绞痛的中国患者中对阻塞性CAD具有一定的整体诊断效能。
  • 该显像在识别多支血管病变患者的罪犯缺血血管方面表现出很高的PPV。

研究设计与样本

  • 前瞻性纳入136例非急性胸痛、心电图正常、肌钙蛋白阴性且疑似不稳定型心绞痛的中国患者。
  • 所有患者在1周内接受静息18F-FDG PET显像和冠状动脉造影。

主要发现

  • 71例患者诊断为阻塞性CAD,130个血管区域确认狭窄≥70%。
  • 患者水平:灵敏度62.0%、特异度92.3%、准确率76.5%、PPV 89.8%、NPV 69.0%、AUC 0.771。
  • 血管水平:灵敏度47.7%、特异度94.2%、准确率79.4%、PPV 79.5%、NPV 79.4%、AUC 0.710。
  • 71例阻塞性CAD患者中,全部血管水平与单支血管病变的灵敏度分别为47.7%和58.8%,特异度分别为91.6%和91.2%,准确率分别为64.8%和80.4%,PPV分别为89.9%和76.9%,NPV分别为52.8%和81.6%。
  • 两支或三支血管病变患者中,灵敏度43.8%、特异度93.3%、准确率50.5%、PPV 97.7%、NPV 20.6%,AUC分别为0.696、0.750和0.685。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aimed to determine the clinical value of rest 18F-FDG imaging in Chinese patients with non-acute chest pain, normal ECG, negative troponin, and suspected UA. METHODS: 136 patients were prospectively included and underwent rest 18F-FDG PET imaging and coronary arteriography within 1 week. RESULTS: Obstructive CAD was diagnosed in 71 patients, and stenosis ≥ 70% was confirmed in 130 vascular territories. At patients and vascular level, rest 18F-FDG imaging showed sensitivity of 62.0%, 47.7%, specificity of 92.3%, 94.2%, accuracy of 76.5%, 79.4%, PPV of 89.8% and 79.5%, and NPV of 69.0% and 79.4%. The AUCs were 0.771 and 0.710. Of 71 patients with obstructive CAD, rest 18F-FDG imaging showed sensitivity of 47.7% and 58.8%, specificity of 91.6% and 91.2%, accuracy of 64.8% and 80.4%, PPV of 89.9% and 76.9% and NPV of 52.8% and 81.6% in all vascular level and single-vessel disease. In patients with two- or three-vessel disease, rest 18F-FDG imaging had a diagnostic sensitivity, specificity, accuracy, PPV, and NPV of 43.8%, 93.3%, 50.5%, 97.7%, and 20.6%. The AUCs were 0.696, 0.750, and 0.685. CONCLUSION: Rest 18F-FDG imaging performed certain overall diagnostic efficiency for obstructive CAD in Chinese patients with suspected UA, especially the excellent high PPV in identifying culprit ischemic territory in patients with multivessel disease.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Yang X, Zhang F, Chen Y, et al. Value of rest 18F-FDG myocardial imaging in the diagnosis of obstructive coronary artery disease in Chinese patients with suspected unstable angina: A prospective real-world clinical study. J Nucl Cardiol. 2022. PMID: 35915328. doi:10.1007/s12350-022-03068-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。