文献速递肿瘤 PET/CT放射性药物与辐射防护

18F-FDG标记白细胞PET/CT在检测隐匿性感染方面相较于18F-FDG PET/CT扫描的增量价值

Incremental Value of 18 F-FDG-Labeled Leukocytes PET/CT Over 18 F-FDG PET/CT Scan in the Detection of Occult Infection.
PubMed 文献 · Clin Nucl Med · 2022-07-06

这项前瞻性观察性诊断准确性研究纳入33例不明原因发热或疑似假体周围感染且C反应蛋白和总白细胞计数升高的患者,所有患者分两天分别接受18F-WBC PET/CT和18F-FDG PET/CT。结果显示18F-WBC PET/CT对感染的诊断准确性显著高于18F-FDG PET/CT(P<0.05)。

要点

  • 18F-WBC PET/CT对隐匿性感染的诊断准确性显著高于18F-FDG PET/CT(P<0.05)。
  • 18F-WBC PET/CT视觉分析和定量分析均在分级1b时诊断准确性最高。
  • 18F-FDG PET/CT视觉分析和定量分析均在分级2时诊断准确性最高。

核心结论

  • 18F-WBC PET/CT对隐匿性感染的诊断准确性高于18F-FDG PET/CT。

研究设计与样本

  • 前瞻性观察性诊断准确性研究,纳入33例不明原因发热或疑似假体周围感染且C反应蛋白和总白细胞计数升高的患者。
  • 所有患者使用标准方案在2个不同日期分别接受18F-WBC PET/CT和18F-FDG PET/CT扫描。
  • 图像由基于摄取强度的视觉分析和基于病灶与背景SUVmax比值的定量分级共同评估。
  • 最终诊断通过组织病理学、微生物学分析或临床-影像学检查确定,平均临床随访8个月(范围1-15个月)。

主要发现

  • 25/33例患者中通过18F-FDG PET/CT或18F-WBC PET/CT发现29个疑似感染灶,8例患者两种扫描均未见异常摄取。
  • 29个疑似感染灶中18个证实为感染(14/18通过组织病理学/微生物学培养,其余4/18通过临床/影像学检查)。
  • 29个疑似病灶中11个经穿刺或活检培养证实为非感染性,其中7/11通过临床/影像学检查证实为非感染性。
  • 18F-FDG PET/CT与18F-WBC PET/CT在视觉分析和定量分析分级1b时各有28个部位结果一致。
  • 18F-WBC PET/CT对感染的诊断准确性显著高于18F-FDG PET/CT(P<0.05)。

关键数值与推荐

  • 18F-FDG PET/CT视觉评分:0级(不可探测或无摄取)、1a级(低于肝脏摄取)、1b级(等于肝脏摄取)、2级(高于肝脏摄取)、3级(高于小脑摄取)。
  • 18F-WBC PET/CT视觉评分:0级(不可探测或无摄取);1a级(躯干部病灶显著低于腰椎或肝脏摄取,肢体病灶略高于邻近软组织摄取或低于邻近骨髓摄取);1b级(躯干部病灶等于肝脏或腰椎摄取,肢体病灶显著高于邻近软组织摄取或高于邻近骨髓摄取);2级(高于肝脏或骨髓摄取);3级(高于肝脏或骨髓摄取的两倍)。
  • 两种显像的定量分级基于病灶与背景SUVmax比值:<1.5为0级,1.5-2.5为1a级,2.5-3.5为1b级,3.5-4.5为2级,>4.5为3级。
  • 18F-WBC PET/CT在视觉分析和定量分析分级1b(病灶与背景SUVmax比值2.5-3.5)时诊断准确性最高。
  • 18F-FDG PET/CT在视觉分析和定量分析分级2时诊断准确性最高。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Differentiating infection and sterile inflammation is the main clinical concern of clinicians as they are closely related to each other. Although 18 F-FDG PET/CT imaging is widely used, its main disadvantage is its lack of specificity to discriminate aseptic from septic inflammation. 18 F-WBC PET/CT scan is a promising tool for the accurate diagnosis of infection owing to its high specificity. The aim of the present study is to determine the utility of 18 F-WBC PET/CT in the diagnosis of occult infections and to assess its incremental value over routine 18 F-FDG PET/CT scan. PATIENTS AND METHODS: This prospective observational diagnostic accuracy study included 33 patients with fever of unknown origin or suspected periprosthetic infection and raised C-reactive protein and total leukocyte count. All the patients underwent both 18 F-WBC PET/CT scan and 18 F-FDG PET/CT scan using a standard protocol on 2 different days. Images of both the scans were evaluated by both visual analyses based on uptake intensity and quantitative grading based on lesion-to-background SUV max values. For interpretation of FDG PET/CT images, visual scoring of grade 0 (undetectable or no uptake), grade 1a (less than liver uptake), grade 1b (equivalent to liver uptake), grade 2 (higher than liver uptake), and grade 3 (higher than cerebellum uptake) was used. 18 F-WBC PET/CT images were also interpreted visually as grade 0 (undetectable or no uptake), grade 1a (significantly less than lumbar vertebrae or liver uptake for truncal lesions, and in case of extremity lesion slightly higher than neighboring soft tissue uptake or less than neighboring bone marrow uptake), grade 1b (equivalent to liver or lumbar vertebrae uptake for truncal lesions, and in case of extremity lesion significantly higher than neighboring soft tissue uptake or higher than neighboring bone marrow uptake), grade 2 (higher than liver or bone marrow uptake), and grade 3 (higher than twice the liver or bone marrow uptake). Similarly, a quantitative grading was also done based on lesion-to-background SUV max using a circular region of interest manually drawn. For both 18 F-FDG and 18 F-WBC PET/CT, the lesion-to-background ratio of <1.5 was recorded as grade 0, 1.5-2.5 as grade 1a, 2.5-3.5 as grade 1b, 3.5-4.5 as grade 2, and >4.5 as grade 3. Final diagnosis was made by histopathological, microbiological analysis, or clinical-radiological workup. RESULTS: Twenty-nine foci of suspected infection were found in 25/33 patients by either 18 F-FDG PET/CT or 18 F-WBC PET/CT scan. No abnormal uptake of either 18 F-FDG or 18 F-FDG WBC scan was seen in 8 patients. There was a concordance of 18 F-FDG PET/CT and 18 F-WBC PET/CT in 28 sites each using grade 1b of visual and quantitative analysis, respectively. Of the 29 suspicious infected foci, 18 were proven positive for infection (14/18 sites by the histopathological/microbiological culture and the rest 4/18 sites by clinical/radiological workup). Culture of aspirates or biopsy from 11/29 suspicious sites was proven noninfective. Seven of 11 suspicious sites were proven noninfective by clinical/radiological workup. The mean clinical follow-up was 8 months (1-15 months).Overall significantly higher diagnostic accuracy was demonstrated with 18 F-WBC PET/CT in comparison to 18 F-FDG PET/CT for the detection of infection ( P < 0.05). The highest diagnostic accuracy of 18 F-WBC PET/CT scan was reported with both grade 1b of visual as well as of quantitative analysis (lesion-to-background SUV max , 2.5-3.5) and grade 2 for both visual and quantitative analysis for 18 F FDG PET/CT. CONCLUSIONS: 18 F-WBC PET/CT has a higher diagnostic accuracy over 18 F-FDG PET/CT for the diagnosis of occult infection.

来源:Clin Nucl Med,查看原文。版权归原作者所有。

引用

  1. Manda D, Thakral P, Sen I, et al. Incremental Value of 18 F-FDG-Labeled Leukocytes PET/CT Over 18 F-FDG PET/CT Scan in the Detection of Occult Infection. Clin Nucl Med. 2022. PMID: 35776834. doi:10.1097/RLU.0000000000004317

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。