文献速递肿瘤 PET/CT

使用多种分割方法克服图像重建设置对淋巴瘤[18F]FDG PET代谢肿瘤体积评估的影响

Combatting the effect of image reconstruction settings on lymphoma [18F]FDG PET metabolic tumor volume assessment using various segmentation methods.
PubMed 文献 · EJNMMI Res · 2022-07-29

本研究从19例淋巴瘤患者的基线[18F]FDG PET扫描中分割56个病灶,评估9种半自动分割方法得到的代谢肿瘤体积(MTV)对重建方法变化的敏感性,并探索ComBat能否提高MTV可重复性。结果显示SUV4.0法对重建变化最不敏感,ComBat可改善多数分割方法在不同重建间的MTV一致性,其中对数转换版ComBat优于常规版。

要点

  • SUV4.0法得到的MTV对重建方法变化最不敏感,MTV比值中位数1.01、四分位距0.96-1.10。
  • ComBat可改善多数分割方法在不同重建间MTV的一致性。
  • 对数转换版ComBat的MTV对齐精度和准确度优于常规版ComBat。

核心结论

  • MTV同时取决于分割方法和重建方法。
  • ComBat可降低重建相关的MTV变异性,尤其在使用对数转换处理MTV非正态分布时。

研究设计与样本

  • 从19例淋巴瘤患者的基线[18F]FDG PET扫描中分割56个病灶。
  • 每例扫描应用EARL1、EARL2标准和本地临床首选重建方案。
  • 使用9种半自动分割方法勾画病灶:基于SUV的固定阈值(SUV=4、SUV=2.5)、相对阈值(SUVmax的41%[41M]、SUVpeak的50%[A50P])、多数投票法(MV2、MV3)、Nestle阈值法及基于SUVmax选择最优方法的L2A、L2B。
  • 将EARL2和本地临床首选重建得到的MTV与EARL1得到的MTV进行比较,并探索不同版本ComBat对数据的协调效果。

主要发现

  • SUV4.0法得到的MTV对使用不同重建方法最不敏感,MTV比值中位数=1.01,四分位距=[0.96-1.10]。
  • 经ComBat协调后,多数分割方法在不同重建间的MTV一致性得到改善。
  • 使用非转换分布的常规ComBat(Regular ComBat)得到的MTV对齐准确度和精度低于使用对数转换数据集的版本(Log-transformed ComBat)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: [18F]FDG PET-based metabolic tumor volume (MTV) is a promising prognostic marker for lymphoma patients. The aim of this study is to assess the sensitivity of several MTV segmentation methods to variations in image reconstruction methods and the ability of ComBat to improve MTV reproducibility. METHODS: Fifty-six lesions were segmented from baseline [18F]FDG PET scans of 19 lymphoma patients. For each scan, EARL1 and EARL2 standards and locally clinically preferred reconstruction protocols were applied. Lesions were delineated using 9 semiautomatic segmentation methods: fixed threshold based on standardized uptake value (SUV), (SUV = 4, SUV = 2.5), relative threshold (41% of SUVmax [41M], 50% of SUVpeak [A50P]), majority vote-based methods that select voxels detected by at least 2 (MV2) and 3 (MV3) out of the latter 4 methods, Nestle thresholding, and methods that identify the optimal method based on SUVmax (L2A, L2B). MTVs from EARL2 and locally clinically preferred reconstructions were compared to those from EARL1. Finally, different versions of ComBat were explored to harmonize the data. RESULTS: MTVs from the SUV4.0 method were least sensitive to the use of different reconstructions (MTV ratio: median = 1.01, interquartile range = [0.96-1.10]). After ComBat harmonization, an improved agreement of MTVs among different reconstructions was found for most segmentation methods. The regular implementation of ComBat ('Regular ComBat') using non-transformed distributions resulted in less accurate and precise MTV alignments than a version using log-transformed datasets ('Log-transformed ComBat'). CONCLUSION: MTV depends on both segmentation method and reconstruction methods. ComBat reduces reconstruction dependent MTV variability, especially when log-transformation is used to account for the non-normal distribution of MTVs.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Ferrández MC, Eertink JJ, Golla SSV, et al. Combatting the effect of image reconstruction settings on lymphoma [18F]FDG PET metabolic tumor volume assessment using various segmentation methods. EJNMMI Res. 2022. PMID: 35904645. doi:10.1186/s13550-022-00916-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。