静态与动态68Ga-FAPI PET/CT检测胰腺导管内乳头状黏液性肿瘤恶变
本研究在25例MRI或CT证实的胰腺囊性病变患者中评估68Ga-FAPI PET鉴别恶性转化IPMN的临床可行性,其中11例为高危IPMN、11例为低级别IPMN、3例为其他良性病变。高危IPMN的68Ga-FAPI摄取显著高于低级别IPMN和其他良性囊性病变,静态与动态PET参数的受试者工作特征曲线下面积均大于80%。作者结论认为68Ga-FAPI PET有助于区分高危与低级别IPMN,并显示出避免非恶性胰腺IPMN不必要手术的潜力。
要点
- 高危IPMN的68Ga-FAPI摄取显著高于低级别IPMN和其他良性囊性病变。
- 动态成像中高危IPMN时间-活性曲线先升后缓降,低级别IPMN则立即达峰后快速下降约10分钟。
- 静态与动态PET参数鉴别IPMN亚型的曲线下面积均大于80%。
核心结论
- 68Ga-FAPI PET是区分高危与低级别IPMN的有用新工具,并显示出避免非恶性胰腺IPMN不必要手术的潜力。
研究设计与样本
- 在德国海德堡大学医院欧洲胰腺中心随访的25例MRI或CT证实的胰腺囊性病变患者中,因临床、实验室化学或影像学发现可疑而接受手术切除或细针穿刺,全部行静态68Ga-FAPI PET、其中20例行动态68Ga-FAPI PET。
主要发现
- 11例为高危IPMN(6例伴进展为PDAC、5例不伴进展为PDAC),11例为低级别IPMN,3例为其他良性病变。
- 高危IPMN的68Ga-FAPI摄取显著高于低级别IPMN和其他良性囊性病变。
- 动态成像中高危IPMN时间-活性曲线呈上升后缓慢下降,低级别IPMN时间-活性曲线立即达峰后快速下降约10分钟、其余时间下降较慢。
- 静态与动态PET参数鉴别IPMN亚型的受试者工作特征曲线下面积均大于80%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Pancreatic ductal adenocarcinoma (PDAC) may arise from intraductal papillary mucinous neoplasms (IPMN) with malignant transformation, but a significant portion of IPMN remains to show benign behavior. Therefore, it is important to differentiate between benign IPMN and IPMN lesions undergoing malignant transformation. However, nonoperative differentiation by ultrasound, CT, MRI, and carbohydrate antigen 19-9 (CA19-9) is still unsatisfactory. Here, we assessed the clinical feasibility of additional assessment of malignancy by PET using 68Ga-labeled fibroblast activation protein inhibitors (68Ga-FAPI PET) in 25 patients with MRI- or CT-proven cystic pancreatic lesions. Methods: Twenty-five patients with cystic pancreatic lesions who were followed up in the European Pancreas Center of Heidelberg University hospital and who were led to surgical resection or fine-needle aspiration due to suspicious clinical, laboratory chemistry, or radiologic findings were examined by static (all patients) and dynamic (20 patients) 68Ga-FAPI PET. Cystic pancreatic lesions were delineated and SUVmax and SUVmean were determined. Time-activity curves and dynamic parameters (time to peak, K 1, k 2, K3, k 4) were extracted from dynamic PET data. Receiver-operating curves of static and dynamic PET parameters were calculated. Results: Eleven of the patients had menacing IPMN (high-grade IPMN with [6 cases] or without [5 cases] progression into PDAC) and 11 low-grade IPMN; 3 patients had other benign entities. Menacing IMPN showed significantly elevated 68Ga-FAPI uptake compared with low-grade IPMN and other benign cystic lesions. In dynamic imaging, menacing IPMN showed increasing time-activity curves followed by slow decrease afterward; time-activity curves of low-grade IPMN showed an immediate peak followed by rapid decrease for about 10 min and slower decrease for the rest of the time. Receiver-operating curves showed high sensitivity and specificity (area under the curve greater than 80%) of static and dynamic PET parameters for the differentiation of IPMN subtypes. Conclusion: 68Ga-FAPI PET is a helpful new tool for the differentiation of menacing and low-grade IPMN and shows the potential to avoid unnecessary surgery for nonmalignant pancreatic IPMN.
引用
- Lang M, Spektor AM, Hielscher T, et al. Static and Dynamic 68Ga-FAPI PET/CT for the Detection of Malignant Transformation of Intraductal Papillary Mucinous Neoplasia of the Pancreas. J Nucl Med. 2022. PMID: 35906094. doi:10.2967/jnumed.122.264361
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。