高分辨率硅光电倍增管飞行时间专用头部PET系统用于临床脑研究
研究纳入18例受试者行18F-FDG PET、17例受试者行18F-flutemetamol PET,比较专用头部飞行时间PET(dhPET)与常规全身PET/CT(wbPET)的脑成像质量。dhPET所有图像视觉评分均优于wbPET,18F-FDG与18F-flutemetamol的平均皮层SUV比(SUVR)均显著高于wbPET。
要点
- dhPET的18F-FDG与18F-flutemetamol脑图像视觉质量均优于wbPET。
- dhPET的18F-FDG与18F-flutemetamol平均皮层SUVR均显著高于wbPET。
- dhPET与wbPET存在区域放射性分布差异,需理解此现象以充分利用dhPET特性。
核心结论
- dhPET图像视觉质量优于wbPET且SUVR更高,虽存在区域分布差异,理解该现象可在临床中充分利用dhPET系统特性。
研究设计与样本
- 采用专用头部的飞行时间PET系统(dhPET)与常规全身PET/CT(wbPET)采集脑18F-FDG和18F-flutemetamol图像。
- 18F-FDG PET研究纳入18例受试者,18F-flutemetamol PET研究纳入17例受试者。
- 18F-FDG与18F-flutemetamol均先用wbPET采集,随后用dhPET采集。
- 图像比较采用视觉评估、体素分析和SUV比(SUVR)。
主要发现
- 所有18F-FDG和18F-flutemetamol的dhPET图像视觉评估均优于wbPET图像。
- 体素分析显示dhPET的18F-FDG图像在小脑、外侧枕叶皮层及中央沟周围区域的放射性聚集低于wbPET,而脑室系统周围聚集高于wbPET。
- dhPET的18F-flutemetamol图像在小脑齿状核、中脑、外侧枕叶皮层及中央沟周围区域的聚集低于wbPET,而脑室系统周围聚集高于wbPET。
- 18F-FDG与18F-flutemetamol的dhPET平均皮层SUVR分别显著高于对应的wbPET图像。
临床怎么用
- 原文结论未据此给出具体临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
We acquired brain 18F-FDG and 18F-flutemetamol PET images using a time-of-flight system dedicated to the head (dhPET) and a conventional whole-body PET/CT (wbPET) system and evaluated the clinical superiority of dhPET over wbPET. Methods: There were 18 subjects for the 18F-FDG PET study and 17 subjects for the 18F-flutemetamol PET study. 18F-FDG PET images were first obtained using wbPET, followed by dhPET. 18F-flutemetamol PET images were first obtained using wbPET, followed by dhPET. Images acquired using dhPET and wbPET were compared by visual inspection, voxelwise analysis, and SUV ratio (SUVR). Results: All 18F-FDG and 18F-flutemetamol images acquired using dhPET were judged as visually better than those acquired using wbPET. The voxelwise analysis demonstrated that accumulations in the cerebellum, in the lateral occipital cortices, and around the central sulcus area in dhPET 18F-FDG images were lower than those in wbPET 18F-FDG images, whereas accumulations around the ventricle systems were higher in dhPET 18F-FDG images than those in wbPET 18F-FDG images. Accumulations in the cerebellar dentate nucleus, in the midbrain, in the lateral occipital cortices, and around the central sulcus area in dhPET images were lower than those in wbPET images, whereas accumulations around the ventricle systems were higher in dhPET 18F-flutemetamol images than those in wbPET 18F-flutemetamol images. The mean cortical SUVRs of 18F-FDG and 18F-flutemetamol dhPET images were significantly higher than those of 18F-FDG and 18F-flutemetamol wbPET images, respectively. Conclusion: The dhPET images had better image quality by visual inspection and higher SUVRs than wbPET images. Although there were several regional accumulation differences between dhPET and wbPET images, understanding this phenomenon will enable full use of the features of this dhPET system in clinical practice.
引用
- Ishii K, Hanaoka K, Watanabe S, et al. High-Resolution Silicon Photomultiplier Time-of-Flight Dedicated Head PET System for Clinical Brain Studies. J Nucl Med. 2022. PMID: 35798557. doi:10.2967/jnumed.122.264080
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。