文献速递肿瘤 PET/CT放射性药物与辐射防护

不明原因发热的分子影像学:进展更新

Molecular Imaging of Fever of Unknown Origin: An Update.
PubMed 文献 · Semin Nucl Med · 2022-07-26

本文系统检索了分子影像学用于不明原因发热诊断的原始研究,共纳入63篇文献、5094例患者。18F-FDG PET/CT的加权平均灵敏度84.4%、特异度61.8%、准确率76.3%,在儿童、老年人、结缔组织病患者、肾脏替代治疗患者及HIV感染者等特定人群中也有良好诊断价值。67Ga-枸橼酸盐显像和白细胞显像的灵敏度分别为42.2%和73.5%。作者认为18F-FDG PET/CT是首选的分子诊断影像技术,67Ga-枸橼酸盐和白细胞显像仅在18F-FDG PET/CT不可用时考虑。

要点

  • 18F-FDG PET/CT诊断不明原因发热的加权平均灵敏度84.4%、特异度61.8%、准确率76.3%。
  • 67Ga-枸橼酸盐显像加权平均灵敏度42.2%、特异度80.3%。
  • 白细胞显像加权平均灵敏度73.5%、特异度86.3%、准确率79.5%。

核心结论

  • 18F-FDG PET/CT是不明原因发热首选的分子诊断影像技术,67Ga-枸橼酸盐和白细胞显像仅在18F-FDG PET/CT不可用时考虑。

研究设计与样本

  • 系统文献检索纳入63篇评估5094例不明原因发热患者的原始研究。

主要发现

  • 18F-FDG PET/CT的加权平均灵敏度84.4%、特异度61.8%、阳性预测值80.7%、阴性预测值67.8%、准确率76.3%、有帮助率61.1%。
  • 18F-FDG PET/CT在儿童、老年人、结缔组织病患者、肾脏替代治疗患者及HIV感染者等特定人群中也有良好诊断价值。
  • 67Ga-枸橼酸盐显像的加权平均灵敏度42.2%、特异度80.3%、阳性预测值82.4%、阴性预测值41.9%、有帮助率42.2%。
  • 白细胞显像的加权平均灵敏度73.5%、特异度86.3%、阳性预测值79.1%、阴性预测值82.4%、准确率79.5%。
  • 与67Ga-枸橼酸盐和白细胞显像相比,18F-FDG PET/CT的研究数量显著更多,且18F-FDG PET/CT具有操作时间相对较短的优点。

关键数值与推荐

  • 18F-FDG PET/CT加权平均灵敏度84.4%、特异度61.8%、阳性预测值80.7%、阴性预测值67.8%、准确率76.3%、有帮助率61.1%。
  • 67Ga-枸橼酸盐显像加权平均灵敏度42.2%、特异度80.3%、阳性预测值82.4%、阴性预测值41.9%、有帮助率42.2%。
  • 白细胞显像加权平均灵敏度73.5%、特异度86.3%、阳性预测值79.1%、阴性预测值82.4%、准确率79.5%。

临床怎么用

  • 作者认为18F-FDG PET/CT是首选的分子诊断影像技术。
  • 作者认为67Ga-枸橼酸盐和白细胞显像仅在18F-FDG PET/CT不可用时考虑。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

18F-FDG PET/CT, 67Ga-citrate and white blood cell (WBC) scintigraphy are molecular imaging techniques currently used in the diagnostic workup of fever of unknown origin. However, it is unknown which technique fits which patient group best. A systematic literature search has been performed for original articles regarding the use of molecular imaging in fever of unknown origin. A total of 820 eligible studies were screened of which 63 articles evaluating 5094 patients met the inclusion criteria. 18F-FDG PET/CT provided good diagnostic accuracy (with a weighted mean sensitivity, specificity, positive predicting value, negative predictive value, accuracy and helpfulness of 84.4%, 61.8%, 80.7%, 67.8%, 76.3%, and 61.1%, respectively). Even within specific patient groups such as children, elderly, patients with connective tissue diseases, patients on renal replacement therapy, and HIV-infected patients, 18F-FDG PET/CT provided good diagnostic values. For 67Ga-citrate scintigraphy, the weighted mean sensitivity, specificity, positive predictive value, negative predictive value, and helpfulness were 42.2%, 80.3%, 82.4%, 41.9%, and 42.2%, respectively. WBC scintigraphy shows a weighted mean sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 73.5%, 86.3%, 79.1%, 82.4%, and 79.5%, respectively. However, compared to 67Ga-citrate and WBC scintigraphy, significantly more research has been performed using 18F-FDG PET/CT and 18F-FDG PET/CT has the advantage of relatively short procedural duration; it is therefore the preferred molecular diagnostic imaging technique. 67Ga-citrate and WBC scintigraphy can only be considered if 18F-FDG PET/CT is not available.

来源:Semin Nucl Med,查看原文。版权归原作者所有。

引用

  1. van Rijsewijk ND, IJpma FFA, Wouthuyzen-Bakker M, et al. Molecular Imaging of Fever of Unknown Origin: An Update. Semin Nucl Med. 2022. PMID: 35902280. doi:10.1053/j.semnuclmed.2022.07.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。