整合CTPA的18F-FDG PET/CT改进肺动脉肿块影像诊断策略
研究纳入79例CTPA显示肺动脉充盈缺损且疑为肺动脉恶性肿瘤并接受18F-FDG PET/CT的患者,以病理或临床影像随访为诊断依据。结果显示至少5个CT征象共存可完美识别恶性肿块,而≤4个CT征象不能准确区分肿块性质;18F-FDG PET/CT参数(SUV、MTV、TLG)检测恶性肿块的诊断准确性优良,在具有3或4个病理CT征象的患者中SUVmax>3.4可显著提高恶性肿瘤的识别。
要点
- 至少5个CT征象共存可完美识别恶性肺动脉肿块,≤4个CT征象不能准确区分肿块性质。
- 恶性肿块的SUVmax、SUVmean、MTV和TLG均值显著高于良性肿块。
- 在具有3或4个病理CT征象的患者中,SUVmax>3.4可显著提高恶性肿瘤的识别。
核心结论
- CTPA是诊断肺动脉肿块的有用影像方法,尤其在识别至少5个异常CT征象时。
- 18F-FDG PET/CT能准确识别恶性肿块,并为CTPA后的诊断不确定性提供额外有价值的信息。
研究设计与样本
- 从2889例CTPA显示肺动脉充盈缺损的患者中,连续纳入79例疑为肺动脉恶性肿瘤并随后接受18F-FDG PET/CT的患者。
- 所有肿块基于病理结果或临床影像随访进行诊断。
主要发现
- 膨胀性生长、边缘不规则、侵犯、CT对比剂摄取和壁蚀征与肿块恶性性质强烈相关。
- 至少5个CT征象共存可完美识别恶性肿块,而≤4个CT征象不能准确区分肿块性质。
- 恶性肿块的SUVmax、SUVmean、MTV和TLG均值显著高于良性肿块。
- 18F-FDG PET/CT参数(SUV、MTV和TLG)检测恶性肿块的诊断准确性优良。
- 在具有3或4个病理CT征象的患者中,SUVmax>3.4显著提高恶性肿瘤的识别。
关键数值与推荐
- 至少5个CT征象共存可完美识别恶性肿块。
- 在具有3或4个病理CT征象的患者中,SUVmax>3.4显著提高恶性肿瘤的识别。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the diagnostic accuracy of computed tomography pulmonary angiography (CTPA) and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) for pulmonary artery (PA) masses. METHODS: Of 2889 patients with PA filling defects of PA on CTPA, 79 consecutive patients suspicious for PA malignancy who subsequently underwent 18F-FDG PET/CT were enrolled. All masses were diagnosed on the basis of pathological findings or clinical imaging follow-up. For each mass, morphological CT signs, standardized uptake value (SUVmax and SUVmean), metabolic tumor volume (MTV), and total lesion glycolysis (TLG) on 18F-FDG PET/CT were used as diagnostic markers. RESULTS: Expansive growth, irregular margin, invasion, CT contrast uptake, and wall eclipse sign were strongly associated with the malignant nature of masses. The coexistence of at least 5 CT signs perfectly identified malignant masses, whereas the detection of no more than 4 CT signs did not accurately discriminate between the natures of masses. Mean SUVmax, SUVmean, MTV, and TLG values were significantly higher in malignant masses compared to those in benign masses. The diagnostic accuracy of 18F-FDG PET/CT parameters (SUV, MTV, and TLG) was excellent in detecting malignant masses. Among patients with 3 or 4 pathological CT signs, SUVmax > 3.4 significantly increased the identification of malignancies. CONCLUSIONS: CTPA is a useful imaging modality for diagnosing PA masses, especially when at least 5 abnormal CT signs are identified. Similarly, 18F-FDG PET/CT accurately identified malignant masses and provided additional valuable information on diagnostic uncertainties after CTPA.
引用
- Hong C, Hou P, Chen HM, et al. Improving the imaging diagnostic strategy for pulmonary artery masses based on 18F-FDG PET/CT integrated with CTPA. Eur J Nucl Med Mol Imaging. 2022. PMID: 35732973. doi:10.1007/s00259-022-05851-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。