文献速递心脏核医学放射性药物与辐射防护

PET/CT衰减校正图定量冠状动脉钙化评分的可重复性:与心电门控CT扫描的比较

Reproducibility of quantitative coronary calcium scoring from PET/CT attenuation maps: comparison to ECG-gated CT scans.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2022-06-25

本研究从2928例同日接受82Rb心脏PET/CT及门控冠状动脉钙化(CAC)扫描的患者中随机选取200例无血运重建史者,比较标准门控CAC扫描与超低剂量非门控CT衰减校正(CTAC)扫描的CAC评分。两种扫描方案间读者一致性指数为0.69和0.72,Cohen Kappa分别为0.75和0.8;读者间一致性标准CAC扫描高于CTAC扫描(Kappa 0.92 vs 0.85,P=0.02)。结论认为CTAC图可定量评估CAC且与标准扫描一致性良好,但对小病灶敏感性有限。

要点

  • CTAC图可定量评估CAC,与标准门控扫描一致性良好。
  • 读者间一致性标准CAC扫描高于CTAC扫描(Kappa 0.92 vs 0.85,P=0.02)。
  • 两种方案不一致的判读多见于钙化程度低的扫描(CAC评分<100)。

核心结论

  • CAC可在PET CTAC图上定量评估,与标准扫描一致性良好,但对小病灶敏感性有限。
  • CTAC的CAC评分可常规进行,无需修改PET方案或增加辐射剂量。

研究设计与样本

  • 从2928例同日接受82Rb心脏PET/CT与门控CAC扫描的患者中随机选取200例无血运重建史者。
  • 由两名读者使用定量临床软件对标准CAC扫描与非门控CTAC扫描进行评分。
  • 采用Cohen Kappa和一致性指数在5个CAC分类(0、1-10、11-100、101-400、>400)中评估读者间及两种扫描方案间的一致性。

主要发现

  • 患者中位年龄70岁(四分位距63-77),46%为男性。
  • 读者1的扫描间一致性指数为0.69,Cohen Kappa为0.75(95%CI 0.69, 0.81)。
  • 读者2的扫描间一致性指数为0.72,Cohen Kappa为0.8(95%CI 0.75, 0.85)。
  • 读者间一致性指数和Cohen Kappa标准CAC扫描为0.9和0.92(95%CI 0.89, 0.96),CTAC扫描为0.83和0.85(95%CI 0.79, 0.9),Kappa差异P=0.02。
  • 两种方案间大多数不一致判读见于钙化程度低的扫描(CAC评分<100)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: We sought to evaluate inter-scan and inter-reader agreement of coronary calcium (CAC) scores obtained from dedicated, ECG-gated CAC scans (standard CAC scan) and ultra-low-dose, ungated computed tomography attenuation correction (CTAC) scans obtained routinely during cardiac PET/CT imaging. METHODS: From 2928 consecutive patients who underwent same-day 82Rb cardiac PET/CT and gated CAC scan in the same hybrid PET/CT scanning session, we have randomly selected 200 cases with no history of revascularization. Standard CAC scans and ungated CTAC scans were scored by two readers using quantitative clinical software. We assessed the agreement between readers and between two scan protocols in 5 CAC categories (0, 1-10, 11-100, 101-400, and > 400) using Cohen's Kappa and concordance. RESULTS: Median age of patients was 70 (inter-quartile range: 63-77), and 46% were male. The inter-scan concordance index and Cohen's Kappa for readers 1 and 2 were 0.69; 0.75 (0.69, 0.81) and 0.72; 0.8 (0.75, 0.85) respectively. The inter-reader concordance index and Cohen's Kappa (95% confidence interval [CI]) was higher for standard CAC scans: 0.9 and 0.92 (0.89, 0.96), respectively, vs. for CTAC scans: 0.83 and 0.85 (0.79, 0.9) for CTAC scans (p = 0.02 for difference in Kappa). Most discordant readings between two protocols occurred for scans with low extent of calcification (CAC score < 100). CONCLUSION: CAC can be quantitatively assessed on PET CTAC maps with good agreement with standard scans, however with limited sensitivity for small lesions. CAC scoring of CTAC can be performed routinely without modification of PET protocol and added radiation dose.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Pieszko K, Shanbhag AD, Lemley M, et al. Reproducibility of quantitative coronary calcium scoring from PET/CT attenuation maps: comparison to ECG-gated CT scans. Eur J Nucl Med Mol Imaging. 2022. PMID: 35751666. doi:10.1007/s00259-022-05866-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。