利用卷积神经网络在全身PET/CT成像中直接推断Patlak参数图像

Direct inference of Patlak parametric images in whole-body PET/CT imaging using convolutional neural networks.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2022-06-18

本研究提出并探讨了从标准化摄取值(SUV)和/或动态PET图像序列估计Patlak流入速率常数(Ki)的可行性。采用19例受试者的全身18F-FDG动态PET图像(13帧或pass)训练残差深度学习模型,以SUV和/或动态序列为输入、Ki-Patlak(斜率)图像为输出,进行九折交叉验证。结果表明,以SUV加pass 13至9为输入的模型预测参数与参考Patlak图像相比具有可接受的偏差,且病灶可检测性相当。

要点

  • 以SUV加pass 13至9为输入的模型,全患者MRAE%为7.45±0.94%,RE%为4.54±2.93%。
  • 以pass 13至11为输入的预测结果与SUV加pass 13至9输入的结果几乎相似。
  • 偏差随增加pass至pass 11持续降低,之后误差降低幅度可忽略。

核心结论

  • 本研究结论为:基于深度学习的直接方法可在无需输入函数且使用较少pass数的情况下估计Ki-Patlak参数图,具有可行性。
  • 这将使全身动态成像的采集时间缩短,且偏差可接受、病灶可检测性性能相当。

研究设计与样本

  • 本研究采用19例受试者的全身18F-FDG动态PET图像,包含13帧或pass,用于训练残差深度学习模型。
  • 模型以SUV和/或动态序列为输入,以Ki-Patlak(斜率)图像为输出,训练和评估采用九折交叉验证方案。
  • 数据集分为「有SUV」和「无SUV」两组;「有SUV」组开发了6个模型,「无SUV」组开发了5个模型。

主要发现

  • 以SUV加pass 13至9为输入预测的模型,全患者MRAE%为7.45±0.94%,RE%为4.54±2.93%,PSNR为46.89±2.93,SSIM为1.00±6.7×10^-7。
  • 以pass 13至11为输入的预测参数与以SUV加pass 13至9为输入的预测模型结果几乎相似。
  • 偏差随增加pass至pass 11持续降低,之后误差降低幅度可忽略;因此以SUV加pass 13至9的预测模型量化偏差最低。
  • 在SUV和Ki-Patlak图像中一方或双方不可见的病灶,在预测图像中视觉检查表现相似,偏差可容忍。

关键数值与推荐

  • 模型性能评估计算了预测Ki-Patlak图像与参考Ki-Patlak图像之间的MAE、ME、MRAE%、RE%、MSE、RMSE、PSNR和SSIM。
  • 参考Ki-Patlak图像通过使用全部采集数据集的Patlak分析生成。
  • ROI绘制在代表性器官(包括肺、肝、脑和心脏)以及识别的恶性病灶周围。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study proposed and investigated the feasibility of estimating Patlak-derived influx rate constant (Ki) from standardized uptake value (SUV) and/or dynamic PET image series. METHODS: Whole-body 18F-FDG dynamic PET images of 19 subjects consisting of 13 frames or passes were employed for training a residual deep learning model with SUV and/or dynamic series as input and Ki-Patlak (slope) images as output. The training and evaluation were performed using a nine-fold cross-validation scheme. Owing to the availability of SUV images acquired 60 min post-injection (20 min total acquisition time), the data sets used for the training of the models were split into two groups: "With SUV" and "Without SUV." For "With SUV" group, the model was first trained using only SUV images and then the passes (starting from pass 13, the last pass, to pass 9) were added to the training of the model (one pass each time). For this group, 6 models were developed with input data consisting of SUV, SUV plus pass 13, SUV plus passes 13 and 12, SUV plus passes 13 to 11, SUV plus passes 13 to 10, and SUV plus passes 13 to 9. For the "Without SUV" group, the same trend was followed, but without using the SUV images (5 models were developed with input data of passes 13 to 9). For model performance evaluation, the mean absolute error (MAE), mean error (ME), mean relative absolute error (MRAE%), relative error (RE%), mean squared error (MSE), root mean squared error (RMSE), peak signal-to-noise ratio (PSNR), and structural similarity index (SSIM) were calculated between the predicted Ki-Patlak images by the two groups and the reference Ki-Patlak images generated through Patlak analysis using the whole acquired data sets. For specific evaluation of the method, regions of interest (ROIs) were drawn on representative organs, including the lung, liver, brain, and heart and around the identified malignant lesions. RESULTS: The MRAE%, RE%, PSNR, and SSIM indices across all patients were estimated as 7.45 ± 0.94%, 4.54 ± 2.93%, 46.89 ± 2.93, and 1.00 ± 6.7 × 10-7, respectively, for models predicted using SUV plus passes 13 to 9 as input. The predicted parameters using passes 13 to 11 as input exhibited almost similar results compared to the predicted models using SUV plus passes 13 to 9 as input. Yet, the bias was continuously reduced by adding passes until pass 11, after which the magnitude of error reduction was negligible. Hence, the predicted model with SUV plus passes 13 to 9 had the lowest quantification bias. Lesions invisible in one or both of SUV and Ki-Patlak images appeared similarly through visual inspection in the predicted images with tolerable bias. CONCLUSION: This study concluded the feasibility of direct deep learning-based approach to estimate Ki-Patlak parametric maps without requiring the input function and with a fewer number of passes. This would lead to shorter acquisition times for WB dynamic imaging with acceptable bias and comparable lesion detectability performance.