左心室功能与充盈压的超声心动图指标与焦磷酸盐显像血池活性无关
本研究纳入189例转诊行焦磷酸盐(PYP)显像的患者,评估平面显像血池活性与超声心动图左心室功能指标的关系。在PYP SPECT阴性者中,11例有显著血池活性;有与无血池活性者的心脏功能指标无显著差异。作者结论认为约8%的PYP SPECT阴性患者有显著血池活性,应常规行SPECT以避免误判。
要点
- 189例转诊行PYP显像者中,43例(23%)存在ATTR-CA。
- PYP SPECT阴性者中11例有显著血池活性,约占8%。
- 有无血池活性者的超声心动图功能指标无显著差异。
核心结论
- 约8%的PYP SPECT阴性患者存在显著血池活性。
- 有无血池活性的患者之间心脏功能指标无差异。
- 作者认为应常规行PYP SPECT以避免假象解读。
研究设计与样本
- 评估189例转诊行PYP闪烁显像患者的临床与影像数据。
- 所有患者均行平面显像和SPECT(诊断标准)。
主要发现
- 43例(23%)患者存在ATTR-CA。
- PYP SPECT阴性者中11例有显著血池活性。
- 与无ATTR-CA者相比,ATTR-CA患者LVEF、SVi和GLS更低,LAP更高。
- 无ATTR-CA者中,有无血池活性者的上述参数无显著差异。
关键数值与推荐
- PYP SPECT阴性者中,平面图像左心室持续血池活性推断标准为视觉评分≥2或HCL比值≥1.5。
- 视觉评分<2且HCL<1.5时推断无血池活性。
- LVEF、GLS、SVi和LAP由标准经胸超声心动图计算。
临床怎么用
- 作者结论认为应常规行PYP SPECT以避免假象解读。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Pyrophosphate (PYP) imaging has a high diagnostic accuracy for transthyretin cardiac amyloidosis (ATTR-CA). Indeterminate findings are often reported due to persistent blood pool activity, presumed to be from low cardiac output. We evaluated the relationship between blood pool activity on PYP imaging and echocardiographic indices of cardiac function. METHODS: Clinical and imaging data of 189 patients referred for PYP scintigraphy were evaluated. All patients underwent planar imaging and SPECT (diagnostic standard). Among those with a negative PYP SPECT, persistent left ventricular blood pool activity on planar images was inferred by a visual score ≥2 or a heart-to-contralateral (HCL) ratio ≥ 1.5. Absence of blood pool activity was inferred when both visual score was < 2 and HCL was < 1.5. Left ventricular ejection fraction (LVEF), global longitudinal strain (GLS), stroke volume index (SVi), and left atrial pressure (LAP) were calculated from standard transthoracic echocardiograms. RESULTS: ATTR-CA was present in 43 (23%) patients. Among those with a negative PYP SPECT, 11 patients had significant blood pool activity. Patients with ATTR-CA had a lower LVEF, SVi, and GLS, with a higher LAP, compared to those without ATTR-CA. Among those without ATTR-CA, there were no significant differences in these parameters. CONCLUSION: Approximately 8% of patients with a negative PYP SPECT have significant blood pool activity. Measures of cardiac function are not different among those with and without blood pool activity. PYP SPECT should be routinely performed in all patients to avoid false image interpretation.
引用
- Asif T, Gupta A, Murthi M, et al. Echocardiographic indices of left ventricular function and filling pressure are not related to blood pool activity on pyrophosphate scintigraphy. J Nucl Cardiol. 2022. PMID: 35578000. doi:10.1007/s12350-022-02989-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。