文献速递神经核医学

脑血流与淀粉样蛋白负荷对SUVR偏倚的影响

Impact of cerebral blood flow and amyloid load on SUVR bias.
PubMed 文献 · EJNMMI Res · 2022-05-12

本研究在主要为认知未受损的参与者中比较半定量标准化摄取值比(SUVR)与分布容积比(DVR),采用双时间窗方案分别以[18F]氟替美他莫(N=90)或[18F]氟倍他苯(N=31)扫描。结果显示SUVR与DVR虽高度相关(全脑皮层平均R²≥0.85),但SUVR相对DVR存在大幅高估和比例偏倚,且SUVR偏倚与底层Aβ负荷强相关,而相对脑血流对偏倚的影响似乎有限。

要点

  • SUVR与DVR高度相关(全脑皮层平均R²≥0.85),但SUVR相对DVR存在大幅高估和比例偏倚。
  • SUVR及SUVR偏倚与R1均呈负相关,但未达统计学显著。
  • SUVR相对DVR的偏倚与底层Aβ负荷强相关,相对脑血流的影响似乎有限。

核心结论

  • SUVR相对DVR的偏倚与底层Aβ负荷强相关,在主要为认知未受损的人群中相对脑血流对SUVR偏倚的影响似乎有限。

研究设计与样本

  • 参与者按双时间窗方案扫描,使用[18F]氟替美他莫(N=90)或[18F]氟倍他苯(N=31)。
  • 采用经验证的基于基函数的二步简化参考组织模型实现推导DVR和R1参数图像,SUVR由注射后90至110分钟计算,均以小脑灰质为参考组织。
  • 使用线性回归和Bland-Altman分析比较区域SUVR与DVR,并应用广义线性模型评估全脑皮层平均、楔前叶、后扣带回和眶额区的R1能否解释SUVR相对DVR的偏倚。

主要发现

  • SUVR与DVR相关性高(全脑皮层平均R²≥0.85),但观察到SUVR相对DVR的大幅高估和比例偏倚。
  • SUVR及SUVR偏倚与R1均呈负相关,但未达统计学显著。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Despite its widespread use, the semi-quantitative standardized uptake value ratio (SUVR) may be biased compared with the distribution volume ratio (DVR). This bias may be partially explained by changes in cerebral blood flow (CBF) and is likely to be also dependent on the extent of the underlying amyloid-β (Aβ) burden. This study aimed to compare SUVR with DVR and to evaluate the effects of underlying Aβ burden and CBF on bias in SUVR in mainly cognitively unimpaired participants. Participants were scanned according to a dual-time window protocol, with either [18F]flutemetamol (N = 90) or [18F]florbetaben (N = 31). The validated basisfunction-based implementation of the two-step simplified reference tissue model was used to derive DVR and R1 parametric images, and SUVR was calculated from 90 to 110 min post-injection, all with the cerebellar grey matter as reference tissue. First, linear regression and Bland-Altman analyses were used to compare (regional) SUVR with DVR. Then, generalized linear models were applied to evaluate whether (bias in) SUVR relative to DVR could be explained by R1 for the global cortical average (GCA), precuneus, posterior cingulate, and orbitofrontal region. RESULTS: Despite high correlations (GCA: R2 ≥ 0.85), large overestimation and proportional bias of SUVR relative to DVR was observed. Negative associations were observed between both SUVR or SUVRbias and R1, albeit non-significant. CONCLUSION: The present findings demonstrate that bias in SUVR relative to DVR is strongly related to underlying Aβ burden. Furthermore, in a cohort consisting mainly of cognitively unimpaired individuals, the effect of relative CBF on bias in SUVR appears limited. EudraCT Number: 2018-002277-22, registered on: 25-06-2018.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Heeman F, Yaqub M, Hendriks J, et al. Impact of cerebral blood flow and amyloid load on SUVR bias. EJNMMI Res. 2022. PMID: 35553267. doi:10.1186/s13550-022-00898-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。