基于人工智能的PET去噪可在数字PET/CT中使[18F]FDG PET采集时间减半
该前瞻性研究纳入195例接受[18F]FDG PET/CT的患者,比较90秒/床位的原始PET与45秒/床位经人工智能去噪的PET。去噪后图像质量与原始PET相似(P=0.80),病灶符合率97.7%,病灶SUL和代谢体积的组内相关系数≥0.97。结论认为人工智能可使数字PET/CT的[18F]FDG PET采集时间减半,同时恢复半时长PET的图像质量。
要点
- 人工智能去噪后45秒/床位PET的图像质量与90秒/床位原始PET相似(P=0.80)。
- PET45AI与PET90的病灶符合率为836/856(97.7%)。
- 病灶SUL和代谢体积的组内相关系数≥0.97,肝脏SULmean的组内相关系数≥0.87。
核心结论
- 人工智能可使数字PET/CT的[18F]FDG PET采集时间减半,同时恢复退化的半时长PET图像质量。
- 作者认为需要开展包括其他PET放射性药物在内的未来多中心研究。
研究设计与样本
- 前瞻性纳入195例转诊接受[18F]FDG PET/CT的患者。
- 体部PET采集以列表模式进行,比较90秒/床位的原始PET90与45秒/床位有或无人工智能去噪的PET45AI和PET45。
- 去噪由SubtlePET™使用深度卷积神经网络完成。
主要发现
- PET45图像质量中等(差8%,中等68%),与PET90的病灶符合率为88.7%。
- PET45AI图像质量与PET90相似(P=0.80),两者均为好92%、中等8%。
- PET90与PET45AI的病灶符合率为836/856(97.7%),7个病灶(0.8%)仅在PET90中检出,13个(1.5%)仅在PET45AI中检出。
- 病灶EARL1 SULpeak在两种PET间无显著差异(P=0.09)。
- PET45AI的病灶标准SULpeak、标准和EARL1 SULmax、LLR及CVliv低于PET90(P<0.0001),而病灶MV和肝脏SULmean高于PET90(P<0.0001)。
局限性
- 作者认为需要开展包括其他PET放射性药物在内的未来多中心研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: We investigated whether artificial intelligence (AI)-based denoising halves PET acquisition time in digital PET/CT. METHODS: One hundred ninety-five patients referred for [18F]FDG PET/CT were prospectively included. Body PET acquisitions were performed in list mode. Original "PET90" (90 s/bed position) was compared to reconstructed ½-duration PET (45 s/bed position) with and without AI-denoising, "PET45AI and PET45". Denoising was performed by SubtlePET™ using deep convolutional neural networks. Visual global image quality (IQ) 3-point scores and lesion detectability were evaluated. Lesion maximal and peak standardized uptake values using lean body mass (SULmax and SULpeak), metabolic volumes (MV), and liver SULmean were measured, including both standard and EARL1 (European Association of Nuclear Medicine Research Ltd) compliant SUL. Lesion-to-liver SUL ratios (LLR) and liver coefficients of variation (CVliv) were calculated. RESULTS: PET45 showed mediocre IQ (scored poor in 8% and moderate in 68%) and lesion concordance rate with PET90 (88.7%). In PET45AI, IQ scores were similar to PET90 (P = 0.80), good in 92% and moderate in 8% for both. The lesion concordance rate between PET90 and PET45AI was 836/856 (97.7%), with 7 lesions (0.8%) only detected in PET90 and 13 (1.5%) exclusively in PET45AI. Lesion EARL1 SULpeak was not significantly different between both PET (P = 0.09). Lesion standard SULpeak, standard and EARL1 SULmax, LLR and CVliv were lower in PET45AI than in PET90 (P < 0.0001), while lesion MV and liver SULmean were higher (P < 0.0001). Good to excellent intraclass correlation coefficients (ICC) between PET90 and PET45AI were observed for lesion SUL and MV (ICC ≥ 0.97) and for liver SULmean (ICC ≥ 0.87). CONCLUSION: AI allows [18F]FDG PET duration in digital PET/CT to be halved, while restoring degraded ½-duration PET image quality. Future multicentric studies, including other PET radiopharmaceuticals, are warranted.