超快30秒全身PET/CT扫描:一项初步研究
这项回顾性研究以术后病理诊断为参考标准,在88例肿瘤患者中比较18F-FDG全身PET/CT 300秒全数据重建(G300)与仅初始30秒数据重建(G30)的诊断价值;G300定性评分更高且肝脏、纵隔SUVmax、SD、SNR存在差异(均P<0.001),但两者敏感性相似(89.09% vs 86.36%,P=0.250),G300准确率79.73%、AUC 0.709高于G30的77.70%和0.695(均P>0.05)。30秒全身PET/CT可满足不能耐受长时间平卧患者的恶性肿瘤临床诊断要求。
要点
- 88例肿瘤患者中,G300定性评分高于G30(P<0.001)。
- G300与G30敏感性相似(89.09% vs 86.36%,P=0.250)。
- G300准确率79.73%、AUC 0.709均高于G30的77.70%和0.695,但P>0.05。
核心结论
- 30秒全身PET/CT可满足不能耐受长时间平卧患者的恶性肿瘤临床诊断要求。
研究设计与样本
- 回顾性研究,纳入88例肿瘤患者,以术后病理诊断为参考标准。
- 18F-FDG注射剂量约3.7 MBq/kg,采集300秒数据,分别用全部300秒数据(G300)和仅初始30秒数据(G30)重建。
- 由两名阅片者独立进行定性和定量评估,比较G300与G30的诊断性能。
主要发现
- G300平均定性评分高于G30(P<0.001)。
- G300与G30在肝脏和纵隔的SUVmax、SD和SNR上存在差异(均P<0.001)。
- G300与G30敏感性相似(89.09% vs 86.36%,P=0.250)。
- G300准确率为79.73%、AUC为0.709,G30准确率为77.70%、AUC为0.695(均P>0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The aim of this study is to explore the diagnostic value of the images obtained in ultrafast 30-s acquisition time by the total-body PET/CT (18F-FDG injection dose of about 3.7 MBq/kg), and to evaluate whether they can meet the requirements of clinical diagnosis or not. METHODS: This retrospective study explored the clinical value of ultrafast 30-s 18F-FDG total-body PET/CT in 88 oncology patients, using the post-surgical pathological diagnosis as the reference standard. The data were acquired over 300 s and reconstructed using all 300-s data (G300) and only the initial 30 s (G30). Two readers independently assessed all images qualitatively and quantitatively. The diagnostic performance was compared between G300 and G30. RESULTS: The G300 average qualitative score was higher than G30 (P < 0.001). G300 and G30 also differed quantitatively in the liver and mediastinum SUVmax, SD, and SNR (all P < 0.001), but had similar sensitivities (89.09% vs. 86.36%, P = 0.250). The G300 group had higher accuracy (79.73%) and a larger area under the curve (0.709) than G30 (77.70% and 0.695, respectively; all P > 0.05). CONCLUSION: The 30-s total-body PET/CT could meet clinical diagnostic requirements for malignant tumors in patients intolerant to prolonged horizontal positioning.
引用
- Zhang Y, Hu P, He Y, et al. Ultrafast 30-s total-body PET/CT scan: a preliminary study. Eur J Nucl Med Mol Imaging. 2022. PMID: 35578037. doi:10.1007/s00259-022-05838-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。