优化腺苷负荷铷-82 PET扫描中左心室射血分数估算:不同重建方案的影响
本研究纳入25名健康志愿者,重复进行铷-82 PET/CT心肌灌注显像,比较指南推荐重建方案与两种缩短数据窗的替代重建方案对负荷左心室射血分数(LVEF)及LVEF储备的影响。结果显示替代方案所得负荷LVEF更高、LVEF储备更大,其中基于铷-82团注到达心脏的动态帧窗方案重复性最佳(31.7%);作者推荐采用该方案,技术条件有限的中心可选用固定60秒数据方案。
要点
- 替代重建方案较指南推荐方案获得更高的负荷LVEF,但差异未全部达到统计学显著。
- 指南推荐方案的LVEF储备低于两种替代方案,差异有统计学意义。
- 基于团注到达的动态帧窗方案重复性最佳(31.7%),作者推荐优先使用。
核心结论
- 作者推荐使用基于铷-82团注到达心脏的动态帧窗(至210秒)重建方案,以改善LVEF重复性和储备评估;技术条件有限的中心可选用固定60秒数据方案。
研究设计与样本
- 研究纳入25名健康志愿者(中位年龄23岁),重复进行铷-82 PET/CT心肌灌注显像,比较指南推荐重建方案与两种替代重建方案的静息和负荷LVEF、LVEF储备及重复性。
主要发现
- 负荷LVEF:指南推荐方案68±7%,固定60秒方案71±7%(P=.08),动态帧窗方案72±7%(P=.04)。
- LVEF储备:指南推荐方案7.8±3.5,固定60秒方案10.1±3.7,动态帧窗方案10.5±3.6,所有P<.001。
- 重复性:指南推荐方案45.3%,固定60秒方案41.2%,动态帧窗方案31.7%,动态帧窗方案重复性最佳。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Left ventricular ejection fraction (LVEF) estimation using adenosine stress myocardial perfusion imaging (MPI) can be challenging. The short half-life of adenosine and the guideline-recommended adenosine infusion stop during Rubidium-82 acquisition protocol may affect the accuracy and repeatability of the LVEF measures. METHODS: This study comprised 25 healthy volunteers (median age 23 years) who underwent repeat myocardial perfusion imaging (MPI) sessions employing Rubidium-82 PET/CT. A guideline-recommended reconstruction protocol was used for both rest and adenosine stress MPI (150-360 s post-radiotracer injection, standardrecon). For the stress MPI protocol, two additional reconstruction protocols were considered; one was employing 60 seconds data (150-210 seconds, shortfixed) and the other a dynamic frame window based on the bolus arrival of Rubidium-82 in the heart until 210 seconds (x-210 seconds, shortindividual). We report rest and stress LVEF, the LVEF reserve, and the LVEF reserve repeatability. RESULTS: Differences in the LVEF assessments were observed between the guideline recommended and alternative reconstruction protocol (LVEF stress MPI: standardrecon = 68 ± 7%, shortfixed = 71 ± 7% (P = .08), shortindividual = 72 ± 7% (P = .04)), and the LVEF reserve was reduced for the guideline-recommended protocol (standardrecon = 7.8 ± 3.5, shortfixed = 10.1 ± 3.7, shortindividual = 10.5 ± 3.6, all P < .001). The best repeatability measures were obtained for the shortindividual protocol (repeatability: standardrecon = 45.3%, shortfixed = 41.2%, shortindividual = 31.7%). CONCLUSION: We recommend using the shortindividual reconstruction protocol for improved LVEF repeatability and reserve assessment. Alternatively, in centers with limited technical support we recommend the use of the shortfixed protocol.
引用
- Lassen ML, Wissenberg M, Byrne C, et al. Optimization of the left ventricle ejection fraction estimate obtained during cardiac adenosine stress 82Rubidium-PET scanning: impact of different reconstruction protocols. J Nucl Cardiol. 2022. PMID: 35415824. doi:10.1007/s12350-022-02946-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。