动态肾脏[68Ga]Ga-DOTA PET/CT的首次经验:与肾显像及房室模型无创估算肾小球滤过率的比较
本研究在12例患者中采集注射[68Ga]Ga-DOTA后30分钟动态PET数据,与常规肾显像视觉判读一致,并用单房室模型估算GFR。PET估算的GFR与血清肌酐推导的GFRCKD相关性良好(ICC 0.74–0.80,PCC 0.74–0.81),尿流未受干扰亚组(n=9)相关性优良(ICC 0.82–0.95,PCC 0.83–0.95);30分钟与15分钟PET数据估算的GFR高度一致(ICC 0.96–0.99,PCC 0.96–0.99)。结论认为肾脏[68Ga]Ga-DOTA PET可作为常规显像的合适替代,15分钟采集足以用于视觉评估和GFR推导。
要点
- 12例患者中,PET与常规肾显像视觉判读结果一致,检出相同梗阻病变。
- PET单房室模型估算GFR与血清肌酐推导GFRCKD相关性良好至优良,尿流未受干扰者更佳。
- 30分钟与15分钟PET数据估算的GFR高度一致,提示15分钟采集可能足够。
核心结论
- 肾脏[68Ga]Ga-DOTA PET可作为常规肾显像的合适替代,视觉评估与常规肾图结果相当。
- 基于PET数据无创单房室模型推导的GFR与血清肌酐推导的GFR值相关性良好,尿流未受干扰患者相关性优良。
- 动态PET采集15分钟足以用于视觉评估和GFR推导。
研究设计与样本
- 在12例患者中于示踪剂注射后立即采集30分钟动态[68Ga]Ga-DOTA PET数据。
- PET与肾显像图像由三名核医学医师共识判读,分割功能性肾皮质获得时间-活性曲线。
- 以腹主动脉PET信号估算动脉输入函数,采用单房室示踪剂动力学模型计算GFR。
- 使用完整30分钟(GFRPET-30)和缩减15分钟(GFRPET-15)PET数据集评估短采集是否足够。
- 采用排除第2至10分钟的改良方法以减少尿液溢出效应,并以血清肌酐推导的GFRCKD(CKD-EPI公式)作为参考标准。
主要发现
- PET图像判读结果与常规闪烁显像相同:2/12例患者为双侧、1/12例患者为右侧尿路梗阻。
- 排除溢出效应的改良方法使模型拟合函数显著改善。
- GFRCKD与GFRPET-30及GFRPET-15的组内相关系数(ICC)为0.74至0.80,Pearson相关系数(PCC)为0.74至0.81。
- 尿流未受干扰亚组(n=9)中相关性良好至优良,ICC为0.82至0.95,PCC为0.83至0.95。
- GFRPET-30与GFRPET-15之间相关性极好,ICC为0.96至0.99,PCC为0.96至0.99。
关键数值与推荐
- 视觉判读:PET与常规闪烁显像结果一致,2/12例双侧尿路梗阻、1/12例右侧尿路梗阻。
- 整体相关性:GFRCKD与GFRPET-30及GFRPET-15的ICC为0.74至0.80,PCC为0.74至0.81。
- 尿流未受干扰亚组(n=9):ICC为0.82至0.95,PCC为0.83至0.95。
- GFRPET-30与GFRPET-15一致性:ICC为0.96至0.99,PCC为0.96至0.99。
临床怎么用
- 原文结论认为肾脏[68Ga]Ga-DOTA PET可作为常规闪烁显像的合适替代。
- 原文结论认为动态PET采集15分钟足以用于视觉评估和GFR推导。
- 原文未据此给出具体的临床推荐或操作建议。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The determination of the glomerular filtration rate (GFR) is decisive for a variety of clinical issues, for example, to monitor the renal function in radionuclide therapy patients. Renal scintigraphy using glomerularly filtered tracers allows combined acquisition of renograms and GFR estimation but requires repeated blood sampling for several hours. In contrast, dynamic PET imaging using the glomerularly filtered tracer [68Ga]Ga-DOTA bears the potential to non-invasively estimate the GFR by compartmental kinetic modelling. Here, we report the, to our knowledge, first comparison of human renal dynamic [68Ga]Ga-DOTA PET imaging in comparison to renal scintigraphy and compare PET-derived to serum creatinine-derived GFR measurements. METHODS: Dynamic [68Ga]Ga-DOTA PET data were acquired for 30 min immediately after tracer injection in 12 patients. PET and renal scintigraphy images were visually interpreted in a consensus read by three nuclear medicine physicians. The functional renal cortex was segmented to obtain time-activity curves. The arterial input function was estimated from the PET signal in the abdominal aorta. Single-compartmental tracer kinetic modelling was performed to calculate the GFR using complete 30-min (GFRPET-30) and reduced 15-min PET data sets (GFRPET-15) to evaluate whether a shorter acquisition time is sufficient for an accurate GFR estimation. A modified approach excluding minutes 2 to 10 was applied to reduce urinary spill-over effects. Serum creatinine-derived GFRCKD (CKD-EPI-formula) was used as reference standard. RESULTS: PET image interpretation revealed the same findings as conventional scintigraphy (2/12 patients with both- and 1/12 patients with right-sided urinary obstruction). Model fit functions were substantially improved for the modified approach to exclude spill-over. Depending on the modelling approach, GFRCKD and both GFRPET-30 and GFRPET-15 were well correlated with interclass correlation coefficients (ICCs) from 0.74 to 0.80 and Pearson's correlation coefficients (PCCs) from 0.74 to 0.81. For a subgroup of patients with undisturbed urinary efflux (n = 9), correlations were good to excellent (ICCs from 0.82 to 0.95 and PCCs from 0.83 to 0.95). Overall, GFRPET-30 and GFRPET-15 were excellently correlated (ICCs from 0.96 to 0.99 and PCCs from 0.96 to 0.99). CONCLUSION: Renal [68Ga]Ga-DOTA PET can be a suitable alternative to conventional scintigraphy. Visual assessment of PET images and conventional renograms revealed comparable results. GFR values derived by non-invasive single-compartmental-modelling of PET data show a good correlation to serum creatinine-derived GFR values. In patients with undisturbed urinary efflux, the correlation was excellent. Dynamic PET data acquisition for 15 min is sufficient for visual evaluation and GFR derivation.
引用
- Kersting D, Sraieb M, Seifert R, et al. First experiences with dynamic renal [68Ga]Ga-DOTA PET/CT: a comparison to renal scintigraphy and compartmental modelling to non-invasively estimate the glomerular filtration rate. Eur J Nucl Med Mol Imaging. 2022. PMID: 35412053. doi:10.1007/s00259-022-05781-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。