文献速递心脏核医学

放射性碘标记金丝桃素作为急性心肌梗死检测示踪剂:猪模型SPECT-CT成像

Radioiodinated hypericin as a tracer for detection of acute myocardial infarction: SPECT-CT imaging in a swine model.
PubMed 文献 · J Nucl Cardiol · 2022-03-16

本研究在6头猪急性心肌梗死模型中静脉给予131I-金丝桃素和99mTc-甲氧基异丁基异腈,行高能和低能准直器SPECT-CT成像并与死后放射自显影及病理对照。131I-金丝桃素SPECT显示室壁热区均经组织学证实为急性心肌梗死,梗死/正常心肌比值15.3±7.7,而99mTc-甲氧基异丁基异腈对应区域为冷区(比值0.029±0.021)。作者认为131I-金丝桃素有望用于急性心肌梗死的临床检测,但需将I-131替换为I-124或I-123方可用于PET或SPECT。

要点

  • 猪急性心肌梗死模型中,131I-金丝桃素SPECT显示的热区均经组织学证实为梗死。
  • 131I-金丝桃素在梗死区摄取为梗死/正常心肌比值15.3±7.7,对应99mTc-甲氧基异丁基异腈为冷区(比值0.029±0.021)。
  • 放射自显影显示梗死区131I-金丝桃素摄取为正常心肌的9.8倍,γ计数显示梗死区平均摄取10.69 ID%/g,为存活心肌的12.05倍。

核心结论

  • 131I-金丝桃素有望用于急性心肌梗死的临床检测,但需将I-131替换为I-124或I-123以分别用于PET或SPECT。

研究设计与样本

  • 建立猪急性心肌梗死模型(n=6),静脉给予131I-金丝桃素和99mTc-甲氧基异丁基异腈,行高能和低能准直器SPECT-CT成像。
  • SPECT图像与心脏CT融合,并与死后放射自显影及宏观和微观病理对照。
  • 进行组织γ计数以确定131I-金丝桃素的生物分布。

主要发现

  • 131I-金丝桃素SPECT显示室壁清晰热区,均经组织学证实为急性心肌梗死。
  • 131I-金丝桃素SPECT热区(梗死/正常心肌比值15.3±7.7)在99mTc-甲氧基异丁基异腈SPECT上为对应冷区(比值0.029±0.021)。
  • 心脏切片放射自显影显示梗死区131I-金丝桃素摄取为正常心肌的9.8倍。
  • γ计数显示梗死区131I-金丝桃素平均摄取为10.69 ID%/g,为存活心肌的12.05倍。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Hypericin (Hyp) is a natural compound with a newly discovered necrosis-avidity, which can be exploited as a necrosis-avid tracer once labeled with radioactive iodine as has been tested in rodent models. This study was to evaluate the effect of radioiodinated Hyp (131I-Hyp) for imaging detection of acute myocardial infarction (AMI) in conditions closer to clinical scenarios. METHODS: We established swine AMI models (n = 6) which were intravenously given 131I-Hyp and 99mTc-sestamibi and underwent SPECT-CT imaging with high- and low-energy collimators. The acquired SPECT images were fused with cardiac CT images and correlated with postmortem autoradiography and macro- and microscopic pathology. Tissue γ counting was performed to determine biodistribution of 131I-Hyp. RESULTS: 131I-Hyp based SPECT indicated clearly hot regions on ventricular walls which were all histologically proved as AMI. Complementally, the hot AMI regions on 131I-Hyp SPECT (infarct/myoc ratio of 15.3 ± 7.7) were inversely cold regions on 99mTc-sestamibi SPECT (infarct/myoc ratio of 0.029 ± 0.021). Autoradiography of heart slices showed 9.8 times higher 131I-Hyp uptake in infarcted over normal myocardium. With γ counting, the mean 131I-Hyp uptake in infarcts was 10.69 ID%/g, 12.05 times of that in viable myocardium. CONCLUSION: 131I-Hyp shows a potential for clinical detection of AMI once I-131 is substituted by its isotope like I-124 or I-123 for PET or SPECT, respectively.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Yang S, Ma J, Li T, et al. Radioiodinated hypericin as a tracer for detection of acute myocardial infarction: SPECT-CT imaging in a swine model. J Nucl Cardiol. 2022. PMID: 35296972. doi:10.1007/s12350-022-02933-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。