文献速递肿瘤 PET/CT放射性药物与辐射防护

126例患者动态全身多参数FDG PET测定的器官和组织18F-FDG摄取正常值

Normal values for 18F-FDG uptake in organs and tissues measured by dynamic whole body multiparametric FDG PET in 126 patients.
PubMed 文献 · EJNMMI Res · 2022-03-07

研究回顾性分析126例前瞻性招募患者(100例无糖尿病、26例糖尿病)的动态全身FDG PET/CT数据,提供13个器官和组织的MRFDG与DVFDG正常值及变异范围,分析时间-放射性曲线,验证直接重建的MRFDG与手动计算Ki的一致性(r²=0.97,p<0.0001),并探索血糖与MRFDG的相关性。

要点

  • 动态全身多参数FDG PET可提供组织MRFDG正常值,个体间变异小,与手动TAC计算一致(r²=0.97,p<0.0001)。
  • 非底物驱动组织未见血糖与MRFDG的相关性,底物驱动组织则见显著相关。
  • 各区域TAC与既往FDG动力学文献一致,多参数指标与手动计算吻合良好。

核心结论

  • 多参数动态全身PET协议提供的MRFDG正常值个体间变异小,与手动TAC计算及文献值一致,有助于准确临床报告和简化全身组织葡萄糖代谢定量估算。

研究设计与样本

  • 回顾性分析126例前瞻性招募患者(100例无糖尿病、26例糖尿病)的动态全身FDG PET/CT数据,使用Siemens Biograph Vision 600 PET/CT扫描仪和70分钟多参数PET采集协议,手动勾画13个区域及代表性病理发现。

主要发现

  • 组织和器官MRFDG值变异小,与相应SUV变异相当。
  • 所有区域TAC与既往发表的FDG动力学一致。
  • 多参数指标与手动TAC计算相关性好(r²=0.97,p<0.0001)。
  • 非底物驱动组织中血糖水平与MRFDG无相关性,底物驱动葡萄糖摄取组织中血糖与MRFDG显著相关。

关键数值与推荐

  • 多参数指标与手动TAC计算Ki和MRFDG的相关系数r²=0.97,p<0.0001。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Dynamic whole-body (D-WB) FDG PET/CT is a recently developed technique that allows direct reconstruction of multiparametric images of metabolic rate of FDG uptake (MRFDG) and "free" FDG (DVFDG). Multiparametric images have a markedly different appearance than the conventional SUV images obtained by static PET imaging, and normal values of MRFDG and DVFDG in frequently used reference tissues and organs are lacking. The aim of this study was therefore to: (1) provide an overview of normal MRFDG and DVFDG values and range of variation in organs and tissues; (2) analyse organ time-activity curves (TACs); (3) validate the accuracy of directly reconstructed MRFDG tissue values versus manually calculated Ki (and MRFDG) values; and (4) explore correlations between demographics, blood glucose levels and MRFDG values. D-WB data from 126 prospectively recruited patients (100 without diabetes and 26 with diabetes) were retrospectively analysed. Participants were scanned using a 70-min multiparametric PET acquisition protocol on a Siemens Biograph Vision 600 PET/CT scanner. 13 regions (bone, brain grey and white matter, colon, heart, kidney, liver, lung, skeletal muscle of the back and thigh, pancreas, spleen, and stomach) as well as representative pathological findings were manually delineated, and values of static PET (SUV), D-WB PET (Ki, MRFDG and DVFDG) and individual TACs were extracted. Multiparametric values were compared with manual TAC-based calculations of Ki and MRFDG, and correlations with blood glucose, age, weight, BMI, and injected tracer dose were explored. RESULTS: Tissue and organ MRFDG values showed little variation, comparable to corresponding SUV variation. All regional TACs were in line with previously published FDG kinetics, and the multiparametric metrics correlated well with manual TAC-based calculations (r2 = 0.97, p < 0.0001). No correlations were observed between glucose levels and MRFDG in tissues known not to be substrate driven, while tissues with substrate driven glucose uptake had significantly correlated glucose levels and MRFDG values. CONCLUSION: The multiparametric D-WB PET scan protocol provides normal MRFDG values with little inter-subject variation and in agreement with manual TAC-based calculations and literature values. The technique therefore facilitates both accurate clinical reports and simpler acquisition of quantitative estimates of whole-body tissue glucose metabolism.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Dias AH, Hansen AK, Munk OL, et al. Normal values for 18F-FDG uptake in organs and tissues measured by dynamic whole body multiparametric FDG PET in 126 patients. EJNMMI Res. 2022. PMID: 35254514. doi:10.1186/s13550-022-00884-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。