本研究探索利用FDG PET-CT影像组学标志物辅助诊断活动性(主动脉周围)主动脉炎的可行性。对50例主动脉炎患者和25例对照者的主动脉进行手动分割,提取107个影像组学特征并用ComBat技术协调,输入机器学习分类器,以临床诊断为金标准评估诊断效用。多个影像组学特征单独使用时准确度84%至86%、AUC 0.83至0.97,影像组学特征组合的AUC为0.80至1.00。

要点

  • 多个影像组学特征单独诊断活动性主动脉炎的准确度为84%至86%,AUC为0.83至0.97。
  • 影像组学特征组合诊断活动性主动脉炎的AUC为0.80至1.00。
  • 所选影像组学特征单独或组合的AUC与当前定性评估标准表现相似。

核心结论

  • 研究勾勒了基于影像组学辅助诊断主动脉炎的方法学框架。
  • 所选影像组学特征单独或组合在识别活动性主动脉炎的AUC方面与当前定性评估标准表现相似。

研究设计与样本

  • 在50例主动脉炎患者和25例对照者的FDG PET-CT图像上手动分割主动脉。
  • 提取107个影像组学特征(包括SUV指标),并使用ComBat技术进行协调。
  • 将单个影像组学特征和影像组学特征组合作为输入用于机器学习分类器。
  • 以临床诊断为金标准,用受试者工作特征曲线下面积(AUC)和准确度评估分类器的诊断效用。

主要发现

  • 多个影像组学特征单独使用时准确度为84%至86%,AUC为0.83至0.97。
  • 影像组学特征组合的表现相似,AUC为0.80至1.00。

关键数值与推荐

  • 单个影像组学特征诊断活动性主动脉炎的准确度为84%至86%,AUC为0.83至0.97。
  • 影像组学特征组合诊断活动性主动脉炎的AUC为0.80至1.00。

临床怎么用

  • 该框架可能支持开发临床决策工具,以更客观和标准化地评估主动脉炎。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim of this study was to explore the feasibility of assisted diagnosis of active (peri-)aortitis using radiomic imaging biomarkers derived from [18F]-Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography (FDG PET-CT) images. METHODS: The aorta was manually segmented on FDG PET-CT in 50 patients with aortitis and 25 controls. Radiomic features (RF) (n = 107), including SUV (Standardized Uptake Value) metrics, were extracted from the segmented data and harmonized using the ComBat technique. Individual RFs and groups of RFs (i.e., signatures) were used as input in Machine Learning classifiers. The diagnostic utility of these classifiers was evaluated with area under the receiver operating characteristic curve (AUC) and accuracy using the clinical diagnosis as the ground truth. RESULTS: Several RFs had high accuracy, 84% to 86%, and AUC scores 0.83 to 0.97 when used individually. Radiomic signatures performed similarly, AUC 0.80 to 1.00. CONCLUSION: A methodological framework for a radiomic-based approach to support diagnosis of aortitis was outlined. Selected RFs, individually or in combination, showed similar performance to the current standard of qualitative assessment in terms of AUC for identifying active aortitis. This framework could support development of a clinical decision-making tool for a more objective and standardized assessment of aortitis.