18F-DOPA PET/CT动态参数在小儿胶质瘤中的作用
该回顾性研究纳入15例可获取动态18F-DOPA PET的小儿脑胶质瘤患者,评估静态参数与动态参数对高级别/低级别及生存的预测价值。结果显示静态参数在高低级别间无显著差异,而曲线累积形态在低级别组更常见(75% vs 27%),且为无进展生存和总生存的独立预测因子。
要点
- 动态18F-DOPA PET的曲线累积形态在低级别组占75%、高级别组占27%。
- T/S、T/N、达峰时间、曲线斜率和动态斜率比在高低级别间无显著差异。
- 多因素分析仅曲线形态保留为无进展生存(P<0.01)和总生存(P<0.05)的预测因子。
核心结论
- 动态18F-DOPA PET分析在分级评估和生存预测方面优于静态参数评估。
- 曲线形态评估是一种简单易用且具有强预测力的参数。
研究设计与样本
- 回顾性纳入15例可获取动态18F-DOPA PET的小儿脑胶质瘤患者。
主要发现
- T/S、T/N、达峰时间、肿瘤时间活动曲线斜率和动态斜率比在高级别与低级别组间无显著差异。
- 曲线累积形态在低级别组占75%、高级别组占27%。
- 无进展生存单因素分析中,曲线累积形态预测更长生存(P<0.001),T/N和动态斜率比呈临界显著性;多因素分析仅曲线形态保留(P<0.01,Harrell C指数0.93-0.95)。
- 总生存单因素分析中,T/N(P<0.05)、动态斜率比(P<0.05)和曲线累积形态(P<0.001)预测生存;多因素模型仅曲线形态保留(P<0.05,Harrell C指数0.86-0.89)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE OF THE REPORT: PET with 18F-DOPA can be used to evaluate grading and aggressiveness of pediatric cerebral gliomas. However, standard uptake parameters may underperform in circumscribed lesions and in diffuse pontine gliomas. In this study, we tested whether dynamic 18F-DOPA PET could overcome these limitations. PATIENTS AND METHODS: Patients with available dynamic 18F-DOPA PET were included retrospectively. Static parameters (tumor/striatum ratio [T/S] and tumor/cortex ratio [T/N]) and dynamic ones, calculated on the tumor time activity curve (TAC), including time-to-peak (TTP), slope steepness, the ratio between tumor and striatum TAC steepness (dynamic slope ratio [DSR]), and TAC shape (accumulation vs plateau), were evaluated as predictors of high/low grading (HG and LG) and of progression-free survival and overall survival. RESULTS: Fifteen patients were included; T/S, T/N, TTP, TAC slope steepness, and DSR were not significantly different between HG and LG. The accumulation TAC shape was more prevalent in the LG than in the HG group (75% vs 27%). On progression-free survival univariate analysis, TAC accumulation shape predicted longer survival (P < 0.001), whereas T/N and DSR showed borderline significance; on multivariate analyses, only TAC shape was retained (P < 0.01, Harrell C index, 0.93-0.95). On overall survival univariate analysis, T/N (P < 0.05), DSR (P < 0.05), and TAC "accumulating" shape predicted survival (P < 0.001); once more, only this last parameter was retained in the multivariate models (P < 0.05, Harrell C index, 0.86-0.89). CONCLUSIONS: Dynamic 18F-DOPA PET analysis outperforms the static parameter evaluation in grading assessment and survival prediction. Evaluation of the curve shape is a simple-to-use parameter with strong predictive power.
引用
- Fiz F, Bini F, Gabriele E, et al. Role of Dynamic Parameters of 18F-DOPA PET/CT in Pediatric Gliomas. Clin Nucl Med. 2022. PMID: 35353725. doi:10.1097/RLU.0000000000004185
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。