通用型与专用型心脏SPECT深度学习的直接与间接衰减校正策略
研究基于GE Discovery NM/CT 570c专用心脏SPECT的270例匿名临床数据开发小视野截断μ图预测策略,并在GE NM/CT 850c通用SPECT的400例匿名临床数据上比较直接与间接衰减校正方法。专用SPECT中全μ图策略的归一化均方误差为1.20±0.72%,优于直接法的2.21±1.17%;通用SPECT中间接法的归一化均方误差为1.37±1.16%,优于直接法的2.57±1.06%。结论认为在两种SPECT上间接法衰减校正性能均优于直接法。
要点
- 专用心脏SPECT全μ图策略归一化均方误差1.20±0.72%,直接法为2.21±1.17%。
- 专用SPECT极性图绝对百分比误差3.24±2.79%(R2=0.9499),直接法4.77±3.96%(R2=0.9213)。
- 通用SPECT间接法归一化均方误差1.37±1.16%,直接法2.57±1.06%。
核心结论
- 研究为小视野专用心脏SPECT开发了生成μ图的策略,在通用型和专用型SPECT中间接法衰减校正性能均优于直接法。
研究设计与样本
- 专用SPECT使用GE Discovery NM/CT 570c扫描的270例匿名临床研究,通用SPECT使用GE NM/CT 850c扫描的400例匿名临床研究,均输入光电峰与散射窗的非衰减校正图像预测μ图或衰减校正图像。
主要发现
- 专用SPECT全μ图策略归一化均方误差1.20±0.72%,直接法2.21±1.17%;极性图绝对百分比误差3.24±2.79%(R2=0.9499)对4.77±3.96%(R2=0.9213)。
- 通用SPECT直接法预测衰减校正图像的归一化均方误差2.57±1.06%,间接法1.37±1.16%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Deep-learning-based attenuation correction (AC) for SPECT includes both indirect and direct approaches. Indirect approaches generate attenuation maps (μ-maps) from emission images, while direct approaches predict AC images directly from non-attenuation-corrected (NAC) images without μ-maps. For dedicated cardiac SPECT scanners with CZT detectors, indirect approaches are challenging due to the limited field-of-view (FOV). In this work, we aim to 1) first develop novel indirect approaches to improve the AC performance for dedicated SPECT; and 2) compare the AC performance between direct and indirect approaches for both general purpose and dedicated SPECT. METHODS: For dedicated SPECT, we developed strategies to predict truncated μ-maps from NAC images reconstructed with a small matrix, or full μ-maps from NAC images reconstructed with a large matrix using 270 anonymized clinical studies scanned on a GE Discovery NM/CT 570c SPECT/CT. For general purpose SPECT, we implemented direct and indirect approaches using 400 anonymized clinical studies scanned on a GE NM/CT 850c SPECT/CT. NAC images in both photopeak and scatter windows were input to predict μ-maps or AC images. RESULTS: For dedicated SPECT, the averaged normalized mean square error (NMSE) using our proposed strategies with full μ-maps was 1.20 ± 0.72% as compared to 2.21 ± 1.17% using the previous direct approaches. The polar map absolute percent error (APE) using our approaches was 3.24 ± 2.79% (R2 = 0.9499) as compared to 4.77 ± 3.96% (R2 = 0.9213) using direct approaches. For general purpose SPECT, the averaged NMSE of the predicted AC images using the direct approaches was 2.57 ± 1.06% as compared to 1.37 ± 1.16% using the indirect approaches. CONCLUSIONS: We developed strategies of generating μ-maps for dedicated cardiac SPECT with small FOV. For both general purpose and dedicated SPECT, indirect approaches showed superior performance of AC than direct approaches.
引用
- Chen X, Zhou B, Xie H, et al. Direct and indirect strategies of deep-learning-based attenuation correction for general purpose and dedicated cardiac SPECT. Eur J Nucl Med Mol Imaging. 2022. PMID: 35169887. doi:10.1007/s00259-022-05718-8