心肌灌注SPECT/CT低剂量CT可在术前患者中检测贫血

Low-dose CT from myocardial perfusion SPECT/CT allows the detection of anemia in preoperative patients.
PubMed 文献 · J Nucl Cardiol · 2022-02-17

该回顾性研究纳入2015年1月1日至2017年12月31日期间接受术前血液检查和心脏SPECT低剂量CT扫描的229例患者,评估低剂量CT对贫血的识别和分级能力。以血红蛋白为标准,室间隔征和主动脉缘征的AUC分别为0.830和0.669(p<0.0001),定量分析AUC为0.893(p=0.29),最佳贫血截断值为4.5 HU。结论认为定量分析诊断贫血的准确性与血细胞比容相似,可能有助于区分不同贫血严重程度。

要点

  • 低剂量CT定量分析检测贫血的AUC为0.893,与血细胞比容诊断准确性相似。
  • 室间隔征和主动脉缘征的AUC分别为0.830和0.669(p<0.0001)。
  • 基于约登指数的最佳贫血截断值为4.5 HU。

核心结论

  • 心脏SPECT检查中低剂量CT图像的定量分析检测贫血的诊断准确性与血细胞比容相似,可能有助于区分不同贫血严重程度。

研究设计与样本

  • 回顾性研究纳入2015年1月1日至2017年12月31日期间接受术前血液检查和心脏SPECT低剂量CT扫描的患者229例,其中贫血110例(轻度57例、中度46例、重度7例)。

主要发现

  • 以血红蛋白值为参考标准,室间隔征和主动脉缘征检测贫血的AUC分别为0.830和0.669(p<0.0001)。
  • 定量分析检测贫血的AUC为0.893(p=0.29),优于主动脉缘征和室间隔征。
  • 基于约登指数的最佳贫血截断值为4.5 HU。

关键数值与推荐

  • 贫血诊断参考标准为血红蛋白值,贫血严重程度分为轻度57例、中度46例、重度7例。
  • 室间隔征AUC 0.830,主动脉缘征AUC 0.669,定量分析AUC 0.893,最佳截断值4.5 HU。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To assess whether low-dose CT for attenuation correction of myocardial perfusion single-photon emission computed tomography (SPECT) allows for identification of anemic patients and grading anemia severity. METHODS AND RESULTS: Patients who underwent a preoperative blood-test and low-dose CT scan, as a part of a cardiac SPECT exam, between 01 January 2015 and 31 December 2017 were enrolled in this retrospective study. Hemoglobin (Hb) levels and hematocrit were derived from clinical records. CT images were visually assessed (qualitative analysis) for the detection of inter-ventricular septum sign (IVSS) and aortic rim sign (ARS) and quantitative analysis were performed. The diagnostic accuracy for detecting anemia was compared using Hb values as the standard of reference. A total of 229 patients were included (110 with anemia; 57 mild; 46 moderate; 7 severe). The AUC of IVSS and ARS were 0.830 and 0.669, respectively (p<0.0001). The quantitative analysis outperformed ARS and IVSS; (AUC of 0.893, p=0.29). The optimal anemia cut-off using Youden index was 4.5 HU. CONCLUSION: Quantitative analysis derived from low-dose CT images, as a part of cardiac SPECT exams, have a diagnostic accuracy similar to that of hematocrit for the detection of anemia and may allow discriminating different anemia severities.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Gennari AG, Grünig H, Benz DC, et al. Low-dose CT from myocardial perfusion SPECT/CT allows the detection of anemia in preoperative patients. J Nucl Cardiol. 2022. PMID: 35175556. doi:10.1007/s12350-021-02899-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。