文献速递心脏核医学

F-18间氟苄胍PET显像评估心肌交感神经支配

F-18 meta-fluorobenzylguanidine PET imaging of myocardial sympathetic innervation.
PubMed 文献 · J Nucl Cardiol · 2022-01-06

本研究评估了F-18间氟苄胍(MFBG)PET显像心肌交感神经支配的可行性,对16例患者进行动态及全身显像、血药动力学和药代动力学建模,并与MIBG SPECT对比。结果显示MFBG心肌摄取快速且持续,动力学参数可重复性好,MFBG SUV与分布容积及MIBG SPECT心纵隔比相关。作者认为MFBG是评估心肌交感神经支配有前景的PET示踪剂。

要点

  • 16例患者接受MFBG PET显像,心肌摄取快速且持续。
  • 注射后1小时和3-4小时平均SUV分别为5.1±2.2和3.4±1.9。
  • MFBG PET-derived VT与MIBG SPECT心纵隔比的Spearman相关系数为0.80。

核心结论

  • MFBG是评估心肌交感神经支配有前景的PET放射性示踪剂。

研究设计与样本

  • 研究纳入16例患者,行MFBG PET胸部30分钟动态显像,并于注射后30分钟至4小时之间进行3次全身采集。
  • 通过多次血样评估血液动力学,采用可逆1室和2室模型进行药代动力学建模。
  • 从截断数据集重新计算动力学速率常数,所有患者同期行MIBG SPECT显像。

主要发现

  • MFBG心肌摄取快速且持续,注射后1小时平均SUV为5.1±2.2,注射后3-4小时平均SUV为3.4±1.9。
  • 平均K1为1.1±0.6 mL/min/g,平均分布容积(VT)为34±22 mL/cm3。
  • 从截断1小时数据集重新计算K1和VT均具有可重复性,组内相关系数分别为0.99和0.91。
  • MFBG SUV与VT之间的Spearman相关系数为0.86,MFBG PET-derived VT与MIBG SPECT-derived心纵隔活度浓度比之间的Spearman相关系数为0.80。

临床怎么用

  • 原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: I-123 meta-iodobenzylguanidine (MIBG) imaging has long been employed to noninvasively assess the integrity of human norepinephrine transporter-1 and, hence, myocardial sympathetic innervation. Positron-emitting F-18 meta-fluorobenzylguanidine (MFBG) has recently been developed for potentially superior quantitative characterization. We assessed the feasibility of MFBG imaging of myocardial sympathetic innervation. METHODS: 16 patients were imaged with MFBG PET (30-minute dynamic imaging of chest, followed by 3 whole-body acquisitions between 30 minutes and 4-hour post-injection). Blood kinetics were assessed from multiple samples. Pharmacokinetic modeling with reversible 1- and 2-compartment models was performed. Kinetic rate constants were re-calculated from truncated datasets. All patients underwent concurrent MIBG SPECT. RESULTS: MFBG myocardial uptake was rapid and sustained; the mean standardized uptake value (SUV (mean ± standard deviation)) was 5.1 ± 2.2 and 3.4 ± 1.9 at 1 hour and 3-4-hour post-injection, respectively. The mean K1 and distribution volume (VT) were 1.1 ± 0.6 mL/min/g and 34 ± 22 mL/cm3, respectively. Both were reproducible when re-calculated from truncated 1-hour datasets (Intraclass Correlation Coefficient of 0.99 and 0.91, respectively). Spearman's ϱ = 0.86 between MFBG SUV and VT and 0.80 between MFBG PET-derived VT and MIBG SPECT-derived heart-to-mediastinum activity concentration ratio. CONCLUSION: MFBG is a promising PET radiotracer for the assessment of myocardial sympathetic innervation.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Grkovski M, Zanzonico PB, Modak S, et al. F-18 meta-fluorobenzylguanidine PET imaging of myocardial sympathetic innervation. J Nucl Cardiol. 2022. PMID: 34993893. doi:10.1007/s12350-021-02813-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。