文献速递神经核医学

123I-FP-CIT SPECT 图像的前瞻性配对比较:360°CZT 相机与传统相机

Prospective Paired Comparison of 123I-FP-CIT SPECT Images Obtained With a 360°-CZT and a Conventional Camera.
PubMed 文献 · Clin Nucl Med · 2022-01-01

本研究前瞻性纳入92例转诊行123I-FP-CIT SPECT 的患者,在传统相机30分钟采集后立即用360°CZT相机分别以纹状体聚焦和脑聚焦各采集15分钟。结果显示CZT相机断层计数灵敏度分别提高+25%和+18%,图像质量评分显著更高(P ≤ 0.04),视觉分析κ值为0.80和0.85,半定量纹状体摄取相关系数为0.75和0.76;不一致病例10/92(11%)的唯一预测因素为高龄。

要点

  • 360°CZT相机在纹状体聚焦和脑聚焦下断层计数灵敏度分别提高+25%和+18%。
  • CZT相机图像质量评分显著高于传统相机(P ≤ 0.04)。
  • 高龄是不一致病例(10/92,11%)的唯一预测因素。

核心结论

  • 无论聚焦模式如何,高灵敏度360°CZT相机与传统相机相比提供的123I-FP-CIT SPECT结果一致,但采集时间更短、图像质量更高,且存在少数不一致病例,可能由其更高空间分辨率解释。

研究设计与样本

  • 前瞻性研究(NCT03980418),纳入转诊行123I-FP-CIT SPECT 的患者,连续在传统相机上采集30分钟后立即在360°CZT相机上分别以纹状体聚焦和脑聚焦各采集15分钟,重建参数设定为对比度相当但CZT相机空间分辨率更高。

主要发现

  • 共纳入92例患者。
  • 360°CZT相机断层计数灵敏度在纹状体聚焦下提高+25%,在脑聚焦下提高+18%。
  • CZT相机图像质量评分显著高于传统相机(P ≤ 0.04)。
  • 两种相机图像比较的视觉分析一致性κ值分别为0.80(纹状体聚焦)和0.85(脑聚焦)。
  • 半定量分析纹状体摄取的相关系数分别为0.75(纹状体聚焦)和0.76(脑聚焦)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study aimed to compare 123I-FP-CIT SPECT imaging obtained from a 360° cadmium-zinc-telluride (CZT) camera with different focus configurations and from a conventional Anger camera. METHODS: This prospective study (NCT03980418) included patients referred to 123I-FP-CIT SPECT imaging who consecutively underwent a 30-minute acquisition on a conventional camera immediately followed by two 15-minute acquisitions on the 360°-CZT camera with, respectively, striatum and brain focus and reconstruction parameters to give equivalent contrast ratios, albeit with higher spatial resolution for the CZT camera. Tomographic count sensitivities were calculated. The images were analyzed through visual, according to 5 independent physicians, and automatic semiquantitative analyses. RESULTS: Ninety-two patients were included in this study. The 360°-CZT camera tomographic count sensitivities showed increases of +25% and +18% for striatum and brain focus, respectively, as well as significantly higher quality scores (P ≤ 0.04) in comparison to the conventional camera. The κ scores of consensual visual analysis were 0.80 and 0.85, and correlation coefficients of semiquantitative analysis for striatum uptakes were 0.75 and 0.76 for the comparisons of images obtained with the 2 cameras, with striatum and brain focus, respectively, for the CZT camera. Advanced age was the single predictor of discordant cases (10/92 [11%]) showing systematically abnormal scans with the conventional camera, potentially as a result of partial volume effect. CONCLUSIONS: Irrespective of focus mode, this high-sensitivity 360°-CZT camera provides concordant 123I-FP-CIT SPECT results when compared with a conventional camera, but with shorter acquisition times, higher image quality, and few discordant cases possibly explained by its higher spatial resolution.

来源:Clin Nucl Med,查看原文。版权归原作者所有。

引用

  1. Piatkova Y, Payoux P, Boursier C, et al. Prospective Paired Comparison of 123I-FP-CIT SPECT Images Obtained With a 360°-CZT and a Conventional Camera. Clin Nucl Med. 2022. PMID: 34874345. doi:10.1097/RLU.0000000000003969

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。