文献速递心脏核医学

99mTc-焦磷酸盐SPECT/CT容积评估运甲状腺素蛋白心脏淀粉样变性:方法学及与心脏功能参数的相关性

Volumetric evaluation of 99mTc-pyrophosphate SPECT/CT for transthyretin cardiac amyloidosis: Methodology and correlation with cardiac functional parameters.
PubMed 文献 · J Nucl Cardiol · 2021-12-14

回顾性分析25例接受心内膜心肌活检和/或基因检测患者的99mTc-PYP SPECT/CT,14例(56%)诊断为ATTR-CA。注射后3小时采集图像,以主动脉血池SUVmax的1.2倍和1.4倍为阈值计算心脏焦磷酸盐容积(CPV1.2和CPV1.4),CPV1.2诊断ATTR-CA的敏感性和特异性最高。在ATTR-CA患者(n=14)中,CPV1.2与左心室射血分数负相关,与左心室后壁厚度和QRS时限正相关,且相关性强于H/CL比值和SUVmax。

要点

  • CPV1.2在诊断ATTR-CA时达到最高的敏感性和特异性。
  • ATTR-CA患者中CPV1.2与左心室射血分数负相关,与左心室后壁厚度和QRS时限正相关。
  • CPV1.2的相关性较H/CL比值和SUVmax更强。

核心结论

  • 99mTc-PYP SPECT/CT容积评估在评估ATTR-CA疾病负荷方面可能优于H/CL比值和SUVmax。
  • 需要更大规模的研究来阐明容积测量能否评估预后和疾病进展。

研究设计与样本

  • 回顾性评估25例接受心内膜心肌活检和/或基因检测患者的99mTc-PYP SPECT/CT扫描。
  • 14例(56%)患者诊断为ATTR-CA。
  • SPECT/CT图像在注射后3小时采集。

主要发现

  • 评估心肌摄取大于1.2倍和1.4倍主动脉血池SUVmax的区域总容积,定义为心脏焦磷酸盐容积(CPV1.2和CPV1.4)。
  • CPV1.2在诊断ATTR-CA中达到最高的敏感性和特异性。
  • 在诊断为ATTR-CA的患者(n=14)中,CPV1.2与左心室射血分数负相关,与左心室后壁厚度和QRS时限正相关。
  • CPV1.2的相关性强于H/CL比值和SUVmax。

关键数值与推荐

  • 心肌摄取阈值定义为大于1.2倍和1.4倍主动脉血池SUVmax,分别对应CPV1.2和CPV1.4。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 需要更大规模的研究来阐明容积测量能否评估预后和疾病进展。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Volumetric evaluation of 99mTechnetium-pyrophosphate (99mTc-PYP) SPECT/CT is a useful method for assessing transthyretin cardiac amyloidosis (ATTR-CA). We investigated the methodology and assessed its relationship with conventional parameters. METHODS AND RESULTS: We retrospectively evaluated 99mTc-PYP SPECT/CT scans of 25 patients who underwent endomyocardial biopsy and/or gene testing. Fourteen (56%) patients were diagnosed with ATTR-CA. SPECT/CT images were acquired at 3 hours after injection. Total volumes of the myocardial regions where uptakes were > 1.2 and 1.4 × aortic blood pool SUVmax were evaluated and defined as cardiac pyrophosphate volume (CPV1.2 and CPV1.4). The heart-to-contralateral lung (H/CL) ratio and myocardial SUVmax were also calculated. CPV1.2 achieved the highest sensitivity and specificity in diagnosing ATTR-CA. In patients diagnosed with ATTR-CA (n = 14), CPV1.2 negatively correlated with left ventricular ejection fraction and positively correlated with left ventricular posterior wall thickness and QRS duration. The correlation was stronger in CPV1.2 than in the H/CL ratio and SUVmax. CONCLUSION: Volumetric evaluation of 99mTc-PYP SPECT/CT may be superior to the H/CL ratio and SUVmax in assessing the disease burden of ATTR-CA. Larger studies are warranted to clarify whether volumetric measurement can assess prognosis and disease progression.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Watanabe S, Nakajima K, Wakabayashi H, et al. Volumetric evaluation of 99mTc-pyrophosphate SPECT/CT for transthyretin cardiac amyloidosis: Methodology and correlation with cardiac functional parameters. J Nucl Cardiol. 2021. PMID: 34907500. doi:10.1007/s12350-021-02857-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。