文献速递神经核医学

11C-匹兹堡化合物B与18F-氟美他莫在PET中白质结合的比较

Comparison of 11C-Pittsburgh Compound B and 18F-Flutemetamol White Matter Binding in PET.
PubMed 文献 · J Nucl Med · 2021-12-16

本研究在61名认知未受损的老年和年轻成人中前瞻性进行MRI、11C-PiB和18F-氟美他莫PET扫描,比较两种示踪剂在白质高信号(WMH)和正常表现白质(NAWM)中的摄取。结果显示两种示踪剂在白质中摄取地形模式相似,与年龄的关联相似,均能有效区分WMH与NAWM,但18F-氟美他莫因半衰期更长、商业可及且结合潜力更高,可作为11C-PiB的替代用于针对多发性硬化的分子影像研究。

要点

  • 在认知未受损成人中,18F-氟美他莫在WMH和NAWM的SUVr均高于11C-PiB(P<0.001)。
  • 老年组WMH和NAWM的两种示踪剂SUVr均高于年轻组(P<0.001)。
  • 两种示踪剂在区分WMH与NAWM方面未见明显差异。

核心结论

  • 11C-PiB和18F-氟美他莫在白质中显示相似的摄取地形模式,在WMH和NAWM中与年龄的关联相似,两者均能有效区分WMH与NAWM;鉴于18F-氟美他莫半衰期更长、商业可及且结合潜力更高,可作为11C-PiB的替代用于针对多发性硬化评估白质完整性的分子影像研究。

研究设计与样本

  • 从社区招募认知未受损的老年和年轻成人(n=61),前瞻性接受MRI、11C-PiB和18F-氟美他莫PET扫描;MRI液体衰减反转恢复图像分割为WMH和NAWM并配准至T1加权MRI,PET图像亦配准至T1加权MRI,以 cerebellar crus 摄取为参考计算WMH和NAWM的SUVr。

主要发现

  • 年轻成人中位年龄38岁(范围30-48岁),老年成人中位年龄67岁(范围61-83岁)。
  • 在老年(P<0.001)和年轻(P<0.001)认知未受损成人中,18F-氟美他莫的WMH和NAWM SUVr均高于11C-PiB。
  • 在WMH(P<0.001)和NAWM(P<0.001)中,老年认知未受损成人的11C-PiB和18F-氟美他莫SUVr均高于年轻成人。
  • 在老年(P<0.001)和年轻(P<0.001)认知未受损成人中,NAWM的11C-PiB和18F-氟美他莫SUVr均高于WMH。
  • 在老年和年轻成人中,11C-PiB与18F-氟美他莫SUVr在区分WMH与NAWM方面未见明显差异。

关键数值与推荐

  • 以 cerebellar crus 摄取为参考计算11C-PiB和18F-氟美他莫的SUVr。
  • WMH和NAWM基于MRI液体衰减反转恢复图像分割。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PET imaging with β-amyloid ligands is emerging as a molecular imaging technique targeting white matter integrity and demyelination. β-amyloid PET ligands such as 11C-Pittsburgh compound B (11C-PiB) have been considered for quantitative measurement of myelin content changes in multiple sclerosis, but 11C-PiB is not commercially available given its short half-life. A 18F PET ligand such as flutemetamol with a longer half-life may be an alternative, but its ability to differentiate white matter hyperintensities (WMH) from normal-appearing white matter (NAWM) and its relationship with age remains to be investigated. Methods: Cognitively unimpaired (CU) older and younger adults (n = 61) were recruited from the community responding to a study advertisement for β-amyloid PET. Participants prospectively underwent MRI, 11C-PiB, and 18F-flutemetamol PET scans. MRI fluid-attenuated inversion recovery images were segmented into WMH and NAWM and registered to the T1-weighted MRI. 11C-PiB and 18F-flutemetamol PET images were also registered to the T1-weighted MRI. 11C-PiB and 18F-flutemetamol SUV ratios (SUVrs) from the WMH and NAWM were calculated using cerebellar crus uptake as a reference for both 11C-PiB and 18F-flutemetamol. Results: The median age was 38 y (range, 30-48 y) in younger adults and 67 y (range, 61-83 y) in older adults. WMH and NAWM SUVrs were higher with 18F-flutemetamol than with 11C-PiB in both older (P < 0.001) and younger (P < 0.001) CU adults. 11C-PiB and 18F-flutemetamol SUVrs were higher in older than in younger CU adults in both WMH (P < 0.001) and NAWM (P < 0.001). 11C-PiB and 18F-flutemetamol SUVrs were higher in NAWM than WMH in both older (P < 0.001) and younger (P < 0.001) CU adults. There was no apparent difference between 11C-PiB and 18F-flutemetamol SUVrs in differentiating WMH from NAWM in older and in younger adults. Conclusion:11C-PiB and 18F-flutemetamol show a similar topographic pattern of uptake in white matter with a similar association with age in WMH and NAWM. 11C-PiB and 18F-flutemetamol can also effectively distinguish between WMH and NAWM. However, given its longer half-life, commercial availability, and higher binding potential, 18F-flutemetamol can be an alternative to 11C-PiB in molecular imaging studies specifically targeting multiple sclerosis to evaluate white matter integrity.

来源:J Nucl Med,查看原文。版权归原作者所有。

引用

  1. Zeydan B, Schwarz CG, Przybelski SA, et al. Comparison of 11C-Pittsburgh Compound B and 18F-Flutemetamol White Matter Binding in PET. J Nucl Med. 2021. PMID: 34916245. doi:10.2967/jnumed.121.263281

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。